{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T18:28:20Z","timestamp":1770143300608,"version":"3.49.0"},"reference-count":39,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2024,5,8]],"date-time":"2024-05-08T00:00:00Z","timestamp":1715126400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2024,5,8]],"date-time":"2024-05-08T00:00:00Z","timestamp":1715126400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Research and Develop Program, West China Hospital of Stomatology, Sichuan University, Chengdu, China","award":["LCYJ2020-YF-1"],"award-info":[{"award-number":["LCYJ2020-YF-1"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2024,7,1]]},"DOI":"10.1016\/j.medengphy.2024.104176","type":"journal-article","created":{"date-parts":[[2024,5,7]],"date-time":"2024-05-07T22:13:04Z","timestamp":1715119984000},"page":"104176","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of the biomechanical behavior between commercial and 3D-printed patient-specific Ti6Al4V\n                    <scp>L<\/scp>\n                    -Shaped titanium plates following le fort i osteotomy using finite element analysis: A technical Note"],"prefix":"10.1088","volume":"129","author":[{"given":"Wael","family":"Telha","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haozhe","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammed Qasem","family":"Al-Watary","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karim","family":"Sakran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Songsong","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nan","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2024,5,8]]},"reference":[{"key":"bib0001","first-page":"1029","type":"other","article-title":"Stability of Le Fort I osteotomy with advancement: a comparison of single maxillary surgery and a two-jaw procedure","volume":"56","author":"Bothur","year":"1998"},{"key":"bib0002","first-page":"351","type":"other","article-title":"Surgical correction of small or retrodisplaced maxillae. The \"dish-face\" deformity","volume":"43","author":"Obwegeser","year":"1969"},{"key":"bib0003","first-page":"168","type":"other","article-title":"L e F ort I osteotomy for non-orthognathic surgery indications: a review","volume":"6","author":"Pingarron Martin","year":"2013"},{"key":"bib0004","first-page":"1080","type":"other","article-title":"Stability of the Le Fort I maxillary osteotomy after rigid internal fixation","volume":"57","author":"Rotter","year":"1999"},{"key":"bib0005","first-page":"243","type":"other","article-title":"Stability of Le Fort I osteotomy with maxillary advancement: a comparison of combined wire fixation and rigid fixation","volume":"53","author":"Egbert","year":"1995"},{"key":"bib0006","first-page":"58","type":"other","article-title":"Comparison of biomechanical behaviour of maxilla following Le Fort I osteotomy with 2- versus 4-plate fixation using 3D-FEA Part 2: impaction surgery","volume":"38","author":"Ata\u00e7","year":"2009"},{"key":"bib0007","first-page":"279","type":"other","article-title":"Stability of orthognathic surgery: a review of rigid fixation","volume":"34","author":"Van Sickels","year":"1996"},{"key":"bib0008","first-page":"271","type":"other","article-title":"Fixation of bimaxillary osteotomies with resorbable plates and screws: experience in 20 consecutive cases","volume":"59","author":"Edwards","year":"2001"},{"key":"bib0009","first-page":"38","type":"other","article-title":"A method for evaluating skeletal relapsing force during maxillomandibular fixation after orthognathic surgery: a preliminary report","volume":"100","author":"Komori","year":"1991"},{"key":"bib0010","first-page":"e12152","type":"other","article-title":"Biomechanical evaluation of Chinese customized three-dimensional printed titanium miniplate in the Lefort I osteotomy: a finite element analysis","volume":"8","author":"Li","year":"2022"},{"key":"bib0011","type":"other","article-title":"Clinical Accuracy of bimaxillary surgery completed with custom prefabricated splints vs. patient-specific surgical guides and plates","volume":"79","author":"Jones","year":"2021"},{"key":"bib0012","first-page":"1","type":"other","article-title":"Accuracy of splint vs splintless technique for virtually planned orthognathic surgery: a voxel-based three-dimensional analysis","volume":"49","author":"Karanxha","year":"2021"},{"key":"bib0013","first-page":"16","type":"other","article-title":"Occlusal load distribution through the cortical and trabecular bone of the human mid-facial skeleton in natural dentition: a three-dimensional finite element study","volume":"197","author":"Janovic","year":"2015"},{"key":"bib0014","first-page":"684","type":"other","article-title":"Three-dimensional finite element analysis of the facial skeleton on simulated occlusal loading","volume":"28","author":"Gross","year":"2001"},{"key":"bib0015","first-page":"1505","type":"other","article-title":"Evaluation of prebent miniplates in fixation of Le Fort I advancement osteotomy with the finite element method","volume":"43","author":"Coskunses","year":"2015"},{"key":"bib0016","first-page":"629","type":"other","article-title":"Stability of the Le Fort I osteotomy with anterior internal fixation alone: a case series","volume":"63","author":"Yoon","year":"2005"},{"key":"bib0017","first-page":"326","type":"other","article-title":"Wroe S. Finite element analysis of three patterns of internal fixation of fractures of the mandibular condyle","volume":"51","author":"Aquilina","year":"2013"},{"key":"bib0018","first-page":"551","type":"other","article-title":"Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis. Part 1: advancement surgery-posterior loading","volume":"34","author":"Erkmen","year":"2005"},{"key":"bib0019","first-page":"404","type":"other","article-title":"Bos RR. A computer study of biodegradable plates for internal fixation of mandibular angle fractures","volume":"59","author":"Tams","year":"2001"},{"key":"bib0020","first-page":"329","type":"other","article-title":"A three-dimensional numerical simulation of mandible fracture reduction with screwed miniplates","volume":"36","author":"Fern\u00e1ndez","year":"2003"},{"key":"bib0021","first-page":"37","type":"other","article-title":"Stability of different fixation methods after reduction malarplasty under average and maximum masticatory forces: a finite element analysis","volume":"22","author":"Al-Watary","year":"2023"},{"key":"bib0022","first-page":"49","type":"other","article-title":"Biomechanical optimization of a custom-made positioning and fixing bone plate for Le Fort I osteotomy by finite element analysis","volume":"68","author":"Huang","year":"2016"},{"key":"bib0023","first-page":"932","type":"other","article-title":"A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia","volume":"8","author":"Osman","year":"2015"},{"key":"bib0024","first-page":"200","type":"other","article-title":"Bite force and oral function in patients with osseointegrated oral implants","volume":"85","author":"Haraldson","year":"1977"},{"key":"bib0025","first-page":"539","type":"other","article-title":"Relationship between myoelectric activity in masticatory muscles and bite force","volume":"93","author":"Haraldson","year":"1985"},{"key":"bib0026","first-page":"55","type":"other","article-title":"Occlusal force pattern in dentitions with mandibular implant-supported fixed cantilever prostheses occluded with complete dentures","volume":"4","author":"Falk","year":"1989"},{"key":"bib0027","first-page":"775","type":"other","article-title":"Comparison of stability of resorbable and titanium fixation systems by finite element analysis after maxillary advancement surgery","volume":"20","author":"Uckan","year":"2009"},{"key":"bib0028","first-page":"300","type":"other","article-title":"Finite element analysis of a tandem screw configuration in sagittal split osteotomy using biodegradable osteosynthesis screws","volume":"16","author":"Maurer","year":"2001"},{"key":"bib0029","first-page":"72","type":"other","article-title":"Biophysical stimulation of bone fracture repair, regeneration and remodelling","volume":"6","author":"Chao","year":"2003"},{"key":"bib0030","first-page":"742","type":"other","article-title":"Two-year follow-up of changes in bite force and occlusal contact area after intraoral vertical ramus osteotomy with and without Le Fort I osteotomy","volume":"43","author":"Choi","year":"2014"},{"key":"bib0031","first-page":"574","type":"other","article-title":"Comparison of the postsurgical stability of the Le Fort I osteotomy using 2- and 4-plate fixation","volume":"61","author":"Murray","year":"2003"},{"key":"bib0032","first-page":"169","type":"other","article-title":"Stability of skeletal class III malocclusion after combined maxillary and mandibular procedures: rigid internal fixation versus wire osteosynthesis of the mandible","volume":"62","author":"Politi","year":"2004"},{"key":"bib0033","first-page":"32","type":"other","article-title":"Simultaneous 3-dimensional Le Fort I\/distraction osteogenesis technique: positional changes","volume":"67","author":"Pinto","year":"2009"},{"key":"bib0034","first-page":"232","type":"other","article-title":"Stability and morbidity of Le Fort I osteotomy with bioresorbable fixation: a randomized controlled trial","volume":"37","author":"Cheung","year":"2008"},{"key":"bib0035","first-page":"1117","type":"other","article-title":"Comparison of biomechanical behaviour of maxilla following Le Fort I osteotomy with 2- versus 4-plate fixation using 3D-FEA. Part 1: advancement surgery","volume":"37","author":"Ata\u00e7","year":"2008"},{"key":"bib0036","first-page":"176","type":"other","article-title":"Experience with functionally stable plate osteosynthesis after forward displacement of the upper jaw","volume":"8","author":"H\u00f6rster","year":"1980"},{"key":"bib0037","first-page":"227","type":"other","article-title":"Appropriate diameter for screws to fix the maxilla following Le Fort I osteotomy: an investigation utilizing finite element analysis","volume":"35","author":"Nagasao","year":"2007"},{"key":"bib0038","first-page":"6316","type":"other","article-title":"Mechanical properties and residual stress measurements of grade IV titanium and Ti-6Al-4V and Ti-13Nb-13Zr titanium alloys after laser treatment","volume":"14","author":"Ja\u017cd\u017cewska","year":"2021"},{"key":"bib0039","first-page":"185","type":"other","article-title":"[Finite element study of maxillary Le Fort-I osteotomy with rigid internal fixation]","volume":"26","author":"Zhou","year":"2010"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453324000778?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453324000778?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104176","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104176\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104176\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104176\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T15:03:25Z","timestamp":1769094205000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104176"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,8]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,5,8]]},"published-print":{"date-parts":[[2024,7,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2024.104176","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,8]]},"assertion":[{"value":"Comparison of the biomechanical behavior between commercial and 3D-printed patient-specific Ti6Al4V\n                      L\n                      -Shaped titanium plates following le fort i osteotomy using finite element analysis: A technical Note","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-08-08","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-06","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-08","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}