{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:32:40Z","timestamp":1785544360262,"version":"3.56.0"},"reference-count":24,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2024,5,18]],"date-time":"2024-05-18T00:00:00Z","timestamp":1715990400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2024,5,18]],"date-time":"2024-05-18T00:00:00Z","timestamp":1715990400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2024,7,1]]},"DOI":"10.1016\/j.medengphy.2024.104184","type":"journal-article","created":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T23:58:35Z","timestamp":1715990315000},"page":"104184","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":6,"title":["Revolutionizing motor dysfunction treatment: A novel closed-loop electrical stimulator guided by multiple motor tasks with predictive control"],"prefix":"10.1088","volume":"129","author":[{"given":"Xudong","family":"Guo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoyue","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Youguo","family":"Hao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,5,18]]},"reference":[{"key":"bib0001","first-page":"136","type":"other","article-title":"Brief report on stroke prevention and treatment in China","author":"Longde","year":"2020"},{"key":"bib0002","first-page":"639","type":"other","article-title":"The improvement of walking ability following stroke","volume":"115","author":"Mehrholz","year":"2018"},{"key":"bib0003","first-page":"121","type":"other","article-title":"Electromyogram-triggered neuromuscular stimulation and stroke motor recovery of arm\/hand functions: a meta-analysis","volume":"223","author":"Bolton","year":"2004"},{"key":"bib0004","first-page":"662","author":"Watanabe","year":"2009","type":"other"},{"key":"bib0005","first-page":"1715","type":"other","article-title":"Can surface neuromuscular electrical stimulation of the wrist and hand combined with routine therapy facilitate recovery of arm function in patients with stroke?","volume":"93","author":"Rosewilliam","year":"2012"},{"key":"bib0006","first-page":"366","type":"other","article-title":"Upper-limb stroke rehabilitation using electrode-array based functional electrical stimulation with sensing and control innovations. Medical Engineering &amp","volume":"38","author":"Kutlu","year":"2016"},{"key":"bib0007","first-page":"263","type":"other","article-title":"Development of network-based multichannel neuromuscular electrical stimulation system for stroke rehabilitation","volume":"52","author":"Qu","year":"2016"},{"key":"bib0008","first-page":"428","type":"other","article-title":"Multi-site system for NMES-based hand function restoration","volume":"26","author":"Crema","year":"2018"},{"key":"bib0009","doi-asserted-by":"publisher","DOI":"10.3390\/mi12080968.","type":"other"},{"key":"bib0010","first-page":"797","type":"other","article-title":"The Extraction of Neural Information from the Surface EMG for the Control of Upper-Limb Prostheses: emerging Avenues and Challenges","volume":"22","author":"Farina","year":"2014"},{"key":"bib0011","first-page":"137330","type":"other","article-title":"Wearable EMG Bridge \u2014 A multiple-gesture reconstruction system using electrical stimulation controlled by the volitional surface electromyogram of a healthy forearm","volume":"8","author":"Bi","year":"2020"},{"key":"bib0012","first-page":"1045","type":"other","article-title":"Design of functional array electrode stimulation system with surface electromyography feedback","volume":"12","author":"Yin","year":"2020"},{"key":"bib0013","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-25553-3_38.","type":"other"},{"key":"bib0014","first-page":"3204","type":"other","article-title":"Is the Use of a Low-Cost sEMG sensor valid to measure muscle fatigue?","volume":"19","author":"Toro","year":"2019"},{"key":"bib0015","first-page":"3521","type":"other","article-title":"Multi-feature gait recognition with DNN based on SEMG signals","volume":"18","author":"Yao","year":"2021"},{"key":"bib0016","first-page":"2203","type":"other","article-title":"Recursive identification of hammerstein systems with discontinuous nonlinearities containing dead-zones","volume":"48","author":"Voros","year":"2003"},{"key":"bib0017","first-page":"5115","type":"other","article-title":"Position estimation error reduction using recursive-least-square adaptive filter for model-based sensorless interior permanent-magnet synchronous motor drives","volume":"61","author":"Wang","year":"2014"},{"key":"bib0018","first-page":"2276","type":"other","article-title":"Hierarchical recursive least squares algorithms for Hammerstein nonlinear autoregressive output-error systems","volume":"35","author":"Kang","year":"2021"},{"key":"bib0019","first-page":"404","type":"other","article-title":"Reliability and validity of arm function assessment with standardized guidelines for the Fugl-Meyer test, action research arm test and box and block test: a multicentre study","volume":"19","author":"Platz","year":"2005"},{"key":"bib0020","type":"other","article-title":"FES-UPP: a flexible functional electrical stimulation system to support upper limb functional activity practice","volume":"12","author":"Sun","year":"2018"},{"key":"bib0021","type":"other","article-title":"A systematic review on functional electrical stimulation based rehabilitation systems for upper limb post-stroke recovery","volume":"14","author":"Khan","year":"2023"},{"key":"bib0022","first-page":"2299","type":"other","article-title":"Evoked electromyography-based closed-loop torque control in functional electrical stimulation","volume":"60","author":"Zhang","year":"2013"},{"key":"bib0023","first-page":"335","type":"other","article-title":"Evoked electromyographically controlled electrical stimulation","volume":"10","author":"Hayashibe","year":"2016"},{"key":"bib0024","first-page":"6812","type":"other","article-title":"sEMG bias-driven functional electrical stimulation system for upper-limb stroke rehabilitation","volume":"18","author":"Zhou","year":"2018"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453324000857?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453324000857?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104184","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104184\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104184\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104184\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T15:03:48Z","timestamp":1769094228000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2024.104184"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,18]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,5,18]]},"published-print":{"date-parts":[[2024,7,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2024.104184","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,18]]},"assertion":[{"value":"Revolutionizing motor dysfunction treatment: A novel closed-loop electrical stimulator guided by multiple motor tasks with predictive control","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-09-03","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-17","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-18","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}