{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T06:32:48Z","timestamp":1769149968397,"version":"3.49.0"},"reference-count":49,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2025,3,21]],"date-time":"2025-03-21T00:00:00Z","timestamp":1742515200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2025,3,21]],"date-time":"2025-03-21T00:00:00Z","timestamp":1742515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100003243","name":"Ministry of Health of the Czech Republic","doi-asserted-by":"crossref","award":["NU20-02-00368"],"award-info":[{"award-number":["NU20-02-00368"]}],"id":[{"id":"10.13039\/501100003243","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2025,4,1]]},"DOI":"10.1016\/j.medengphy.2025.104319","type":"journal-article","created":{"date-parts":[[2025,3,22]],"date-time":"2025-03-22T07:25:28Z","timestamp":1742628328000},"page":"104319","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Degradation of the mechanical properties of poly-lactide-caprolactone-collagen composite for pulmonary artery banding after implantation into a rat's peritoneum"],"prefix":"10.1088","volume":"138","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2667-249X","authenticated-orcid":true,"given":"Luk\u00e1\u0161","family":"Horn\u00fd","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucie","family":"Vi\u0161tejnov\u00e1","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tom\u00e1\u0161","family":"Such\u00fd","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eva","family":"Ku\u017eelov\u00e1 Ko\u0161\u0165\u00e1kov\u00e1","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3278-9117","authenticated-orcid":true,"given":"Hynek","family":"Chlup","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jakub","family":"Kronek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-2594-1330","authenticated-orcid":true,"given":"Zbyn\u011bk","family":"Sobotka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3135-6056","authenticated-orcid":true,"given":"Zden\u011bk","family":"Pet\u0159iv\u00fd","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Margit","family":"\u017daloudkov\u00e1","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8625-3786","authenticated-orcid":true,"given":"Krist\u00fdna","family":"Havl\u00ed\u010dkov\u00e1","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ji\u0159\u00ed","family":"Mol\u00e1\u010dek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2025,3,21]]},"reference":[{"key":"bib0001","first-page":"213","type":"other","article-title":"The treatment of certain congenital malformations of the heart by the creation of pulmonic stenosis to reduce pulmonary hypertension and excessive pulmonary blood flow; a preliminary report","volume":"95","author":"Muller","year":"1952"},{"key":"bib0002","first-page":"645","type":"other","article-title":"Pulmonary artery banding","volume":"88","author":"Albus","year":"1984"},{"key":"bib0003","first-page":"549","type":"other","article-title":"Palliative procedures for congenital heart defects","volume":"102","author":"Yuan","year":"2009"},{"key":"bib0004","first-page":"515","type":"other","article-title":"Pulmonary artery banding","volume":"135","author":"Corno","year":"2005"},{"key":"bib0005","first-page":"1652","type":"other","article-title":"Vascular histopathologic reaction to pulmonary artery banding in an in vivo growing porcine model","volume":"34","author":"Nedorost","year":"2013"},{"key":"bib0006","type":"other"},{"key":"bib0007","first-page":"65","type":"other","article-title":"Impact of hybrid procedure on pulmonary arterial dimensions and right ventricular load after biventricular repair","volume":"18","author":"Uhl","year":"2023"},{"key":"bib0008","first-page":"765","type":"other","article-title":"Decremental left ventricular deformation after pulmonary artery band training and subsequent repair in ventriculoarterial discordance","volume":"26","author":"Sun","year":"2013"},{"key":"bib0009","first-page":"190","type":"other","article-title":"Lessons learned from the development of a new hybrid strategy for the management of hypoplastic left heart syndrome","volume":"26","author":"Galantowicz","year":"2005"},{"key":"bib0010","first-page":"1099","type":"other","article-title":"Stenting of the arterial duct and banding of the pulmonary arteries: basis for combined norwood stage I and II repair in hypoplastic left heart","volume":"105","author":"Akintuerk","year":"2002"},{"key":"bib0011","first-page":"202","type":"other","article-title":"Pulmonary artery banding using polytetrafluoroethylene; choice of material","volume":"13","author":"Nezafati","year":"2017"},{"key":"bib0012","first-page":"317","type":"other","article-title":"Pulmonary artery banding: long-term telemetric adjustment","volume":"23","author":"Corno","year":"2003"},{"key":"bib0013","first-page":"515","type":"other","article-title":"Pulmonary artery banding","volume":"135","author":"Corno","year":"2005"},{"key":"bib0014","first-page":"1413","type":"other","article-title":"FloWatch versus conventional pulmonary artery banding","volume":"134","author":"Corno","year":"2007"},{"key":"bib0015","type":"other"},{"key":"bib0016","first-page":"300","type":"other","article-title":"Balloon debanding of the pulmonary artery","volume":"13","author":"Bj\u00f8rnstad","year":"1990"},{"key":"bib0017","first-page":"61","type":"other","article-title":"Balloon dilatation of pulmonary artery banding: Norwegian experience over >20 years","volume":"33","author":"Holmstr\u00f6m","year":"2012"},{"key":"bib0018","type":"other","article-title":"Pulmonary artery debanding in the cath lab: lessons learned!","volume":"9","author":"Zareef","year":"2022"},{"key":"bib0019","first-page":"307","type":"other","article-title":"Percutaneous pulmonary artery debanding","volume":"77","author":"Tomita","year":"2021"},{"key":"bib0020","first-page":"866","type":"other","article-title":"A new strategy for the surgical treatment of aortic coarctation associated with ventricular septal defect in infants using an absorbable pulmonary artery band","volume":"34","author":"Bonnet","year":"1999"},{"key":"bib0021","first-page":"735","type":"other","article-title":"Absorbable pulmonary artery banding: a strategy for reducing reoperations","volume":"51","author":"Daley","year":"2017"},{"key":"bib0022","first-page":"539","type":"other","article-title":"Absorbable pulmonary artery band","volume":"64","author":"Peek","year":"1997"},{"key":"bib0023","first-page":"5528","type":"other","article-title":"The injection molding of biodegradable polydioxanone\u2014A study of the dependence of the structural and mechanical properties on thermal processing conditions","volume":"14","author":"Erben","year":"2022"},{"key":"bib0024","first-page":"235","type":"other","article-title":"Tensile strength retention of resorptive suture materials applied in the stomach wall - an in vitro study","volume":"88","author":"Kreszinger","year":"2018"},{"key":"bib0025","first-page":"1608","type":"other","article-title":"Three-dimensional electrospun poly(Lactide-Co-\u025b-Caprolactone) for small-diameter vascular grafts","volume":"18","author":"Mun","year":"2012"},{"key":"bib0026","first-page":"735","type":"other","article-title":"Mechanical properties of suture materials in general and cutaneous surgery","volume":"103","author":"Naleway","year":"2015"},{"key":"bib0027","first-page":"509","type":"other","article-title":"Mechanical properties of synthetic arterial grafts","volume":"12","author":"Hasegawa","year":"1979"},{"key":"bib0028","first-page":"425","type":"other","article-title":"The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model","volume":"17","author":"Langewouters","year":"1984"},{"key":"bib0029","first-page":"278","type":"other","article-title":"Alterations with age in the viscoelastic properties of Human arterial walls","volume":"18","author":"Learoyd","year":"1966"},{"key":"bib0030","first-page":"445","type":"other","article-title":"The static elastic properties of the arterial wall","volume":"156","author":"Bergel","year":"1961"},{"key":"bib0031","first-page":"1288","type":"other","article-title":"The sustainable release of Vancomycin and its degradation products from nanostructured collagen\/hydroxyapatite composite layers","volume":"105","author":"Such\u00fd","year":"2016"},{"key":"bib0032","first-page":"50","type":"other","article-title":"Evaluation of collagen\/hydroxyapatite electrospun layers loaded with vancomycin, gentamicin and their combination: comparison of release kinetics, antimicrobial activity and cytocompatibility","volume":"140","author":"Such\u00fd","year":"2019"},{"key":"bib0033","first-page":"50","type":"other","article-title":"Vancomycin-loaded collagen\/hydroxyapatite layers electrospun on 3D printed titanium implants prevent bone destruction associated with S. epidermidis infection and enhance osseointegration: comparison of release kinetics, antimicrobial activity and cytocompatibility","volume":"9","author":"Such\u00fd","year":"2021"},{"key":"bib0034","first-page":"7606","type":"other","article-title":"Fabrication of collagen-coated biodegradable polymer nanofiber mesh and its potential for endothelial cells growth: comparison of release kinetics, antimicrobial activity and cytocompatibility","volume":"26","author":"He","year":"2005"},{"key":"bib0035","first-page":"2891","type":"other","article-title":"Development of a composite vascular scaffolding system that withstands physiological vascular conditions: comparison of release kinetics, antimicrobial activity and cytocompatibility","volume":"29","author":"Lee","year":"2008"},{"key":"bib0036","first-page":"813","type":"other","article-title":"Design of polycaprolactone Vascular grafts: comparison of release kinetics, antimicrobial activity and cytocompatibility","volume":"45","author":"Yalcin","year":"2016"},{"key":"bib0037","first-page":"1608","type":"other","article-title":"Three-dimensional electrospun poly(Lactide-Co-\u025b-Caprolactone) for small-diameter vascular grafts: comparison of release kinetics, antimicrobial activity and cytocompatibility","volume":"7","author":"Pan","year":"2017"},{"key":"bib0038","first-page":"183","type":"other","article-title":"Differential outcomes of venous and arterial tissue engineered vascular grafts highlight the importance of coupling long-term implantation studies with computational modeling: comparison of release kinetics, antimicrobial activity and cytocompatibility","volume":"94","author":"Best","year":"2019"},{"key":"bib0039","first-page":"1673","type":"other","article-title":"Resorbable vascular grafts show rapid cellularization and degradation in the ovine carotid: comparison of release kinetics, antimicrobial activity and cytocompatibility","volume":"14","author":"Stowell","year":"2020"},{"key":"bib0040","first-page":"132","type":"other","article-title":"The effect of ethylene oxide sterilization on electrospun vascular grafts made from biodegradable polyesters: comparison of release kinetics, antimicrobial activity and cytocompatibility","volume":"92","author":"Horakova","year":"2018"},{"key":"bib0041","type":"other","article-title":"Characterization of main pulmonary artery and valve annulus region of piglets using echocardiography, uniaxial tensile testing, and a novel non-destructive technique","volume":"9","author":"Sutherland","year":"2022"},{"key":"bib0042","first-page":"17","type":"other","article-title":"The composition and biomechanical properties of human cryopreserved aortas, pulmonary trunks, and aortic and pulmonary cusps","volume":"212","author":"Kub\u00edkov\u00e1","year":"2017"},{"key":"bib0043","first-page":"121","type":"other","article-title":"Age related constitutive laws and stress distribution in human main coronary arteries with reference to residual strain","volume":"12","author":"Valenta","year":"2002"},{"key":"bib0044","first-page":"1039","type":"other","article-title":"Biomaterial applications in cardiovascular tissue repair and regeneration","volume":"10","author":"Lam","year":"2014"},{"key":"bib0045","first-page":"472","type":"other","article-title":"Biomaterials in the development and future of vascular grafts","volume":"37","author":"Xue","year":"2003"},{"key":"bib0046","first-page":"257","type":"other","article-title":"Evaluation of biomechanical properties of expanded-polytetrafluoroethylene? Soft tissue patch after dorsal implantation in the rat to mimic TMJ lateral reconstruction","volume":"28","author":"Lai","year":"2001"},{"key":"bib0047","first-page":"122","type":"other","article-title":"A novel knitted polytetrafluoroethylene patch for cardiovascular surgery","volume":"63","author":"Terakawa","year":"2022"},{"key":"bib0048","first-page":"202","type":"other","article-title":"Mechanical and biological properties of the GORE-TEX expanded polytetrafluoroethylene (PTFE) prosthetic ligament","volume":"196","author":"Bolton","year":"1985"},{"key":"bib0049","first-page":"423","type":"other","article-title":"Anisotropic tensile viscoelastic properties of vascular graft materials tested at low strain rates","volume":"7","author":"Michael Lee","year":"1986"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453325000384?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453325000384?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2025.104319","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2025.104319\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2025.104319\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2025.104319\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T15:01:11Z","timestamp":1769094071000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2025.104319"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,21]]},"references-count":49,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,3,21]]},"published-print":{"date-parts":[[2025,4,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2025.104319","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,21]]},"assertion":[{"value":"Degradation of the mechanical properties of poly-lactide-caprolactone-collagen composite for pulmonary artery banding after implantation into a rat's peritoneum","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-08-13","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-02-26","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-03-21","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}