{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T06:21:58Z","timestamp":1769149318169,"version":"3.49.0"},"reference-count":57,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2025,8,19]],"date-time":"2025-08-19T00:00:00Z","timestamp":1755561600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2025,8,19]],"date-time":"2025-08-19T00:00:00Z","timestamp":1755561600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2025,11,1]]},"DOI":"10.1016\/j.medengphy.2025.104417","type":"journal-article","created":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T00:52:46Z","timestamp":1755651166000},"page":"104417","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Comprehensive analysis of anatomical sites for transcutaneous bilirubin measurements in neonates using Monte Carlo multi-layered simulations"],"prefix":"10.1088","volume":"145","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2614-4331","authenticated-orcid":true,"given":"Umme","family":"Abiha","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Harsh","family":"Saxena","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dip Sankar","family":"Banerjee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saptarshi","family":"Mandal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2025,8,19]]},"reference":[{"key":"br0010","type":"other","article-title":"Neonatal jaundice and associated factors in public hospitals of southern Ethiopia: a multi-center cross-sectional study","volume":"10","author":"Bante","year":"2024"},{"key":"br0020","first-page":"32","type":"other","article-title":"Accuracy of transcutaneous bilirubin level measured by a jm-105 bilirubinometer","volume":"64","author":"Ohishi","year":"2023"},{"key":"br0030","first-page":"181","type":"other","article-title":"Photolysis of bilirubin in serum specimens exposed to room lighting","volume":"387","author":"Rehak","year":"2008"},{"key":"br0040","first-page":"130","type":"other","article-title":"Photolysis and photoisomerization of bilirubin in serum specimens exposed to room lighting","volume":"393","author":"McDonagh","year":"2008"},{"key":"br0050","type":"other"},{"key":"br0060","first-page":"463","type":"other","article-title":"Effects of temperature and light on the stability of bilirubin in plasma samples","volume":"413","author":"Sofronescu","year":"2011"},{"key":"br0070","first-page":"79","type":"other","article-title":"Evaluation of bilirubin degradation in plasma specimen exposed to room light at room temperature","volume":"3","author":"Hussien","year":"2013"},{"key":"br0080","first-page":"645","type":"other","article-title":"Effects of specimen evaporation on quality control","volume":"66","author":"Glenn","year":"1976"},{"key":"br0090","type":"other","article-title":"Demystifying non-invasive approaches for screening jaundice in low resource settings: a review","volume":"11","author":"Abiha","year":"2023"},{"key":"br0100","first-page":"467","type":"other","article-title":"Handheld diffuse reflectance spectroscopy system for noninvasive quantification of neonatal bilirubin and hemoglobin concentrations: a pilot study","volume":"14","author":"Cheng","year":"2022"},{"key":"br0110","type":"other","article-title":"Cephalocaudal progression of neonatal jaundice assessed by transcutaneous bilirubin measurements","volume":"160","author":"Kamphuis","year":"2021"},{"key":"br0120","first-page":"15","type":"other","article-title":"Accuracy of enhanced transcutaneous bilirubinometry according to various measurement sites","volume":"56","author":"Casnocha Lucanova","year":"2021"},{"key":"br0130","type":"other","article-title":"Optimal site for applying transcutaneous bilirubinometer as an outpatient screening tool for neonatal jaundice: a comparison between the sternum and forehead","volume":"12","author":"Zhang","year":"2024"},{"key":"br0140","first-page":"548","type":"other","article-title":"The forehead is a better site than the sternum to check transcutaneous bilirubin during phototherapy in sick infants","volume":"20","author":"Jeon","year":"2020"},{"key":"br0150","first-page":"639","type":"other","article-title":"Cumulative ambient light exposure affects outpatient transcutaneous bilirubinometer readings","volume":"12","author":"Zhang","year":"2025"},{"key":"br0160","first-page":"34","type":"other","article-title":"The correlation study of transcutaneous bilirubin measurements in neonates","volume":"4","author":"Kurnianto","year":"2016"},{"key":"br0170","first-page":"209","type":"other","article-title":"Interscapular site for transcutaneous bilirubin measurement in preterm infants: a better and safer screening site","volume":"34","author":"Yaser","year":"2014"},{"key":"br0180","first-page":"32","type":"other","article-title":"Comparison of diagnostic accuracy of different sites for transcutaneous bilirubin measurement in early preterm infants","volume":"86","author":"Agrawal","year":"2019"},{"key":"br0190","first-page":"1058","type":"other","article-title":"Evaluation of bilicare\u2122 transcutaneous bilirubin device in Japanese newborns","volume":"59","author":"Yamana","year":"2017"},{"key":"br0200","first-page":"11","type":"other","article-title":"Influence of assessment site in measuring transcutaneous bilirubin","volume":"12","author":"Concei\u00e7\u00e3o","year":"2014"},{"key":"br0210","first-page":"5835","type":"other","article-title":"Evaluation of a new transcutaneous bilirubinometer in newborn infants","volume":"12","author":"Norman","year":"2022"},{"key":"br0220","first-page":"1058","type":"other","article-title":"Evaluation of bilicare\u2122 transcutaneous bilirubin device in Japanese newborns","volume":"59","author":"Yamana","year":"2017"},{"key":"br0230","first-page":"57","type":"other","article-title":"Accuracy of the bilicare\u2122 transcutaneous bilirubinometer as the predischarge screening tool for significant hyperbilirubinemia in healthy term and late preterm neonates","volume":"33","author":"Chokemungmeepisarn","year":"2020"},{"key":"br0240","first-page":"1628","type":"other","article-title":"Evaluation of a new transcutaneous bilirubinometer","volume":"113","author":"Maisels","year":"2004"},{"key":"br0250","first-page":"678","type":"other","article-title":"Diagnostic properties of a portable point-of-care method to measure bilirubin and a transcutaneous bilirubinometer","volume":"118","author":"Sampurna","year":"2021"},{"key":"br0260","first-page":"283","type":"other","article-title":"Evaluation of the kejian kj-8000 bilirubinometer in an Australian setting","volume":"56","author":"Starowicz","year":"2020"},{"key":"br0270","first-page":"2797","type":"other","article-title":"Development of a mobile phone camera-based transcutaneous bilirubinometer for low-resource settings","volume":"13","author":"Harrison-Smith","year":"2022"},{"key":"br0280","first-page":"933","type":"other","article-title":"Clinical utility of transcutaneous bilirubinometer (tcb) in very low birth weight (vlbw) infants","volume":"44","author":"Quist","year":"2016"},{"key":"br0290","type":"other","article-title":"Evaluation of a point-of-care test for bilirubin in Malawi","volume":"150","author":"Shapiro","year":"2022"},{"key":"br0300","first-page":"69","type":"other","article-title":"The accuracy of transcutaneous bilirubinometer measurements to identify the hyperbilirubinemia in outpatient newborn population","volume":"55","author":"Ercan","year":"2018"},{"key":"br0310","first-page":"131","type":"other","article-title":"MCML-Monte Carlo modeling of light transport in multi-layered tissues","volume":"47","author":"Wang","year":"1995"},{"key":"br0320","author":"Delgado","year":"2011","type":"other"},{"key":"br0330","first-page":"307","author":"Jiang","year":"2020","type":"other"},{"key":"br0340","first-page":"90501","type":"other","article-title":"Peer-to-peer Monte Carlo simulation of photon migration in topical applications of biomedical optics","volume":"17","author":"Doronin","year":"2012"},{"key":"br0350","type":"other","article-title":"Parallel computing with graphics processing units for high-speed Monte Carlo simulation of photon migration","volume":"13","author":"Alerstam","year":"2008"},{"key":"br0360","first-page":"122","type":"other","article-title":"Advances in Monte Carlo simulation for light propagation in tissue","volume":"10","author":"Periyasamy","year":"2017"},{"key":"br0370","type":"other","article-title":"History of Monte Carlo modeling of light transport in tissues using mcml.c","volume":"27","author":"Jacques","year":"2022"},{"key":"br0380","author":"Martelli","year":"2022","type":"other"},{"key":"br0390","doi-asserted-by":"publisher","author":"Yuan","DOI":"10.1101\/2020.10.11.335232","type":"other"},{"key":"br0400","first-page":"4711","type":"other","article-title":"Fullmontecuda: a fast, flexible, and accurate gpu-accelerated Monte Carlo simulator for light propagation in turbid media","volume":"10","author":"Young-Schultz","year":"2019"},{"key":"br0410","author":"Jacques","type":"other"},{"key":"br0430","first-page":"6389","type":"other","article-title":"Non-invasive optical monitoring of human lungs: Monte Carlo modeling of photon migration in visible Chinese human and an experimental test on a human","volume":"13","author":"Guo","year":"2022"},{"key":"br0440","first-page":"44","type":"other","article-title":"A study on tetrahedron-based inhomogeneous Monte Carlo optical simulation","volume":"2","author":"Shen","year":"2010"},{"key":"br0450","first-page":"91","type":"other","article-title":"Mcvm: Monte Carlo modeling of photon migration in voxelized media","volume":"03","author":"Li","year":"2010"},{"key":"br0460","author":"LaRochelle","type":"other"},{"key":"br0470","author":"Massachusetts Green High Performance Computing Center (MGHPCC)","type":"other"},{"key":"br0480","type":"other","article-title":"Toward fluorescence digital twins: multi-parameter experimental validation of fluorescence Monte Carlo simulations using solid phantoms","volume":"30","author":"Nguyen","year":"2025"},{"key":"br0490","first-page":"141","type":"other","article-title":"CONV-convolution for responses to a finite diameter photon beam incident on multi-layered tissues","volume":"54","author":"Wang","year":"1997"},{"key":"br0500","doi-asserted-by":"publisher","author":"Delgado Atencio","DOI":"10.5772\/15853","type":"other"},{"key":"br0510","first-page":"793","type":"other","article-title":"Skin thickness dimensions in histological section measurement during late-fetal and neonatal developmental period: a systematic review","volume":"25","author":"de-Souza","year":"2019"},{"key":"br0520","author":"Atencio","year":"2011","type":"other"},{"key":"br0530","author":"Prahl","type":"other"},{"key":"br0540","type":"other","article-title":"Skin optics","volume":"36","author":"van Gemert","year":"1989"},{"key":"br0550","author":"Tsumura","type":"other"},{"key":"br0560","author":"Randeberg","year":"2005","type":"other"},{"key":"br0570","first-page":"239","type":"other","article-title":"Quantification of cephalocaudal progression of jaundice in preterm infants","volume":"94","author":"Dam-Vervloet","year":"2023"},{"key":"br0580","type":"other","article-title":"Cephalocaudal progression of neonatal jaundice assessed by transcutaneous bilirubin measurements","volume":"160","author":"Kamphuis","year":"2021"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453325001365?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1350453325001365?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2025.104417","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2025.104417\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2025.104417\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2025.104417\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T15:02:02Z","timestamp":1769094122000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1016\/j.medengphy.2025.104417"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,19]]},"references-count":57,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,8,19]]},"published-print":{"date-parts":[[2025,11,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.medengphy.2025.104417","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,19]]},"assertion":[{"value":"Comprehensive analysis of anatomical sites for transcutaneous bilirubin measurements in neonates using Monte Carlo multi-layered simulations","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-11-19","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-08-14","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-08-19","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}