{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T19:15:54Z","timestamp":1786994154864,"version":"build-2736575974"},"reference-count":7,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,3,27]],"date-time":"2017-03-27T00:00:00Z","timestamp":1490572800000},"content-version":"vor","delay-in-days":85,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["MethodsX"],"published-print":{"date-parts":[[2017]]},"DOI":"10.1016\/j.mex.2017.03.002","type":"journal-article","created":{"date-parts":[[2017,3,30]],"date-time":"2017-03-30T17:11:01Z","timestamp":1490893861000},"page":"153-165","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":105,"special_numbering":"C","title":["An ELISA protocol to improve the accuracy and reliability of serological antibody assays"],"prefix":"10.1016","volume":"4","author":[{"given":"Takaki","family":"Waritani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bonnie","family":"McKinney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuniaki","family":"Terato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.mex.2017.03.002_bib0005","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/0022-1759(89)90186-5","article-title":"An improved enzyme-linked immunosorbent assay of anti-collagen antibodies in human serum","volume":"124","author":"Fujii","year":"1989","journal-title":"J. Immunol. Methods"},{"issue":"6","key":"10.1016\/j.mex.2017.03.002_bib0010","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1136\/ard.51.6.783","article-title":"Absence of autoantibodies to peptides shared by HLA-B27.5 and Klebsiella pneumoniae nitrogenase in serum samples from HLA-B27 positive patients with ankylosing spondylitis and Reiter\u2019s syndrome","volume":"51","author":"de Vries","year":"1992","journal-title":"Ann. Rheum. Dis."},{"key":"10.1016\/j.mex.2017.03.002_bib0015","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.jim.2014.03.013","article-title":"Preventing intense false positive and negative reactions attributed to the principle of ELISA to re-investigate antibody studies in autoimmune diseases","volume":"407","author":"Terato","year":"2014","journal-title":"J. Immunol. Methods"},{"key":"10.1016\/j.mex.2017.03.002_bib0020","article-title":"Slipping through the cracks: linking reduced immune function and intestinal bacteria imbalance to the etiology of rheumatoid arthritis","volume":"2015","author":"Terato","year":"2015","journal-title":"Autoimmune Dis."},{"issue":"39","key":"10.1016\/j.mex.2017.03.002_bib0025","doi-asserted-by":"crossref","first-page":"4643","DOI":"10.1016\/j.vaccine.2016.08.007","article-title":"Commentary: preventing further misuse of the ELISA technique and misinterpretation of serological antibody assay data","volume":"34","author":"Terato","year":"2017","journal-title":"Vaccine"},{"issue":"3","key":"10.1016\/j.mex.2017.03.002_bib0030","doi-asserted-by":"crossref","first-page":"1446","DOI":"10.4049\/jimmunol.158.3.1446","article-title":"In patients with rheumatoid arthritis IgG binding to denatured collagen type II is in part mediated by IgG-fibronectin complexes","volume":"158","author":"Mannik","year":"1997","journal-title":"J. Immunol."},{"issue":"1\u20132","key":"10.1016\/j.mex.2017.03.002_bib0035","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.jim.2010.09.009","article-title":"Anti-BSA antibodies are a major cause of non-specific binding in insulin autoantibody radiobinding assays","volume":"362","author":"Williams","year":"2010","journal-title":"J. Immunol. Methods"}],"container-title":["MethodsX"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2215016117300122?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2215016117300122?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,6,23]],"date-time":"2024-06-23T06:29:44Z","timestamp":1719124184000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2215016117300122"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017]]},"references-count":7,"alternative-id":["S2215016117300122"],"URL":"https:\/\/doi.org\/10.1016\/j.mex.2017.03.002","relation":{},"ISSN":["2215-0161"],"issn-type":[{"value":"2215-0161","type":"print"}],"subject":[],"published":{"date-parts":[[2017]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"An ELISA protocol to improve the accuracy and reliability of serological antibody assays","name":"articletitle","label":"Article Title"},{"value":"MethodsX","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.mex.2017.03.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 The Author(s). Published by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}