{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T23:00:18Z","timestamp":1791846018260,"version":"4.3.4"},"reference-count":49,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,2,1]],"date-time":"2017-02-01T00:00:00Z","timestamp":1485907200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,2,1]],"date-time":"2017-02-01T00:00:00Z","timestamp":1485907200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["21275042"],"award-info":[{"award-number":["21275042"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National High Technology Research and Development Program of China","award":["2013AA020203"],"award-info":[{"award-number":["2013AA020203"]}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Microbiological Methods"],"published-print":{"date-parts":[[2017,2]]},"DOI":"10.1016\/j.mimet.2016.12.005","type":"journal-article","created":{"date-parts":[[2016,12,6]],"date-time":"2016-12-06T00:18:00Z","timestamp":1480983480000},"page":"69-75","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":39,"special_numbering":"C","title":["A novel method for the rapid detection of microbes in blood using pleurocidin antimicrobial peptide functionalized piezoelectric sensor"],"prefix":"10.1016","volume":"133","author":[{"given":"Xiaohong","family":"Shi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoqing","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiongqiong","family":"Yao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fengjiao","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.mimet.2016.12.005_bb0005","doi-asserted-by":"crossref","first-page":"1787","DOI":"10.1021\/cr970102g","article-title":"Nanotubes from carbon","volume":"99","author":"Ajayan","year":"1999","journal-title":"Chem. Rev."},{"key":"10.1016\/j.mimet.2016.12.005_bb0010","doi-asserted-by":"crossref","first-page":"M66","DOI":"10.1111\/j.1365-2621.2004.tb13373.x","article-title":"Evaluation of antimicrobial spectrum and cytotoxic activity of pleurocidin for food applications","volume":"69","author":"Burrowes","year":"2004","journal-title":"J. Food Sci."},{"key":"10.1016\/j.mimet.2016.12.005_bb0020","doi-asserted-by":"crossref","first-page":"12008","DOI":"10.1074\/jbc.272.18.12008","article-title":"Isolation and characterization of pleurocidin, an antimicrobial peptide in the skin secretions of winter flounder","volume":"272","author":"Cole","year":"1997","journal-title":"J. Biol. Chem."},{"key":"10.1016\/j.mimet.2016.12.005_bb0025","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1128\/AAC.44.8.2039-2045.2000","article-title":"Characterization of a fish antimicrobial peptide: gene expression, subcellular localization, and spectrum of activity","volume":"44","author":"Cole","year":"2000","journal-title":"Antimicrob. Agents Chemoter."},{"key":"10.1016\/j.mimet.2016.12.005_bb0030","doi-asserted-by":"crossref","first-page":"6826","DOI":"10.1021\/nn2021875","article-title":"Nonvolatile memory device using gold nanoparticles covalently bound to reduced graphene oxide","volume":"5","author":"Cui","year":"2011","journal-title":"ACS Nano"},{"key":"10.1016\/j.mimet.2016.12.005_bb0035","doi-asserted-by":"crossref","first-page":"2023","DOI":"10.1007\/s00253-015-6375-x","article-title":"Antimicrobial peptides: an alternative for innovative medicines?","volume":"99","author":"da Costa","year":"2015","journal-title":"Appl. Microbiol. Biotechnol."},{"key":"10.1016\/j.mimet.2016.12.005_bb0040","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1021\/nl015606f","article-title":"Carbon nanotube inter-and intramolecular logic gates","volume":"1","author":"Derycke","year":"2001","journal-title":"Nano Lett."},{"key":"10.1016\/j.mimet.2016.12.005_bb0045","doi-asserted-by":"crossref","first-page":"1693","DOI":"10.1021\/ac4034938","article-title":"Impedimetric detection of pathogenic gram-positive bacteria using an antimicrobial peptide from class IIa bacteriocins","volume":"86","author":"Etayash","year":"2014","journal-title":"Anal. Chem."},{"key":"10.1016\/j.mimet.2016.12.005_bb0050","doi-asserted-by":"crossref","first-page":"4548","DOI":"10.1021\/nn204999j","article-title":"Critical issues in sensor science to aid food and water safety","volume":"6","author":"Farahi","year":"2012","journal-title":"ACS Nano"},{"key":"10.1016\/j.mimet.2016.12.005_bb0055","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.jinf.2008.07.013","article-title":"Rapid detection of pathogens in blood culture bottles by real-time PCR in conjunction with the pre-analytic tool MolYsis","volume":"57","author":"Gebert","year":"2008","journal-title":"J. Infection."},{"key":"10.1016\/j.mimet.2016.12.005_bb0060","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1007\/s11908-010-0122-3","article-title":"Early identification of sepsis","volume":"12","author":"Gonsalves","year":"2010","journal-title":"Curr. Infect. Dis. Rep."},{"key":"10.1016\/j.mimet.2016.12.005_bb0065","doi-asserted-by":"crossref","first-page":"1872","DOI":"10.2174\/156802610793176648","article-title":"Strategies for the discovery and advancement of novel cationic antimicrobial peptides","volume":"10","author":"Hadley","year":"2010","journal-title":"Curr. Top. Med. Chem."},{"key":"10.1016\/j.mimet.2016.12.005_bb0070","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/S0039-9140(02)00643-4","article-title":"A rapid method for determining Mycobacterium tuberculosis based on a bulk acoustic wave impedance biosensor","volume":"59","author":"He","year":"2003","journal-title":"Talanta"},{"key":"10.1016\/j.mimet.2016.12.005_bb0075","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.mimet.2005.10.015","article-title":"A new MSPQC system for rapid detection of pathogens in clinical samples","volume":"66","author":"He","year":"2006","journal-title":"J. Microbiol. Methods"},{"key":"10.1016\/j.mimet.2016.12.005_bb0080","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1016\/j.snb.2006.11.017","article-title":"The study and application of a new IDE-PQC sensor","volume":"123","author":"He","year":"2007","journal-title":"Sensors Actuators B Chem."},{"key":"10.1016\/j.mimet.2016.12.005_bb0085","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1016\/j.bios.2015.10.054","article-title":"Construction of Au-IDE\/CFP10-ESAT6 aptamer\/DNA-AuNPs MSPQC for rapid detection of Mycobacterium tuberculosis","volume":"77","author":"He","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.mimet.2016.12.005_bb0090","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1007\/s00217-009-1047-7","article-title":"Quantitative determination of Lactobacillus spp. in milk using a series piezoelectric quartz crystal sensor","volume":"229","author":"Jang","year":"2009","journal-title":"Eur. Food Res. Technol."},{"key":"10.1016\/j.mimet.2016.12.005_bb0095","doi-asserted-by":"crossref","first-page":"1928","DOI":"10.1128\/AEM.66.5.1928-1932.2000","article-title":"Antimicrobial peptides protect coho salmon from Vibrio anguillarum infections","volume":"66","author":"Jia","year":"2000","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.mimet.2016.12.005_bb0100","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0062108","article-title":"Rapid diagnosis of bloodstream infections with PCR followed by mass spectrometry","volume":"8","author":"Jordana-Lluch","year":"2013","journal-title":"PLoS One"},{"key":"10.1016\/j.mimet.2016.12.005_bb0105","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1126\/science.287.5453.622","article-title":"Nanotube molecular wires as chemical sensors","volume":"287","author":"Kong","year":"2000","journal-title":"Science"},{"key":"10.1016\/j.mimet.2016.12.005_bb0115","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.snb.2013.10.081","article-title":"Measurement of the evolution of rigid and viscoelastic mass contributions from fibrin network formation during plasma coagulation using quartz crystal microbalance","volume":"192","author":"Lakshmanan","year":"2014","journal-title":"Sensors Actuators B Chem."},{"key":"10.1016\/j.mimet.2016.12.005_bb0120","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.peptides.2012.07.001","article-title":"Overview on the recent study of antimicrobial peptides: origins, functions, relative mechanisms and application","volume":"37","author":"Li","year":"2012","journal-title":"Peptides"},{"key":"10.1016\/j.mimet.2016.12.005_bb0125","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.bios.2014.02.045","article-title":"Impedance based detection of pathogenic E. coli O157: H7 using a ferrocene-antimicrobial peptide modified biosensor","volume":"58","author":"Li","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.mimet.2016.12.005_bb0130","doi-asserted-by":"crossref","first-page":"1365","DOI":"10.1166\/jnn.2006.155","article-title":"Biocompatibility of native and functionalized single-walled carbon nanotubes for neuronal interface","volume":"6","author":"Liopo","year":"2006","journal-title":"J. Nanosci. Nanotechnol."},{"key":"10.1016\/j.mimet.2016.12.005_bb0135","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.bios.2016.01.041","article-title":"Biosensors based on modularly designed synthetic peptides for recognition, detection and live\/dead differentiation of pathogenic bacteria","volume":"80","author":"Liu","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.mimet.2016.12.005_bb0140","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0072349","article-title":"Comparison of pathogen DNA isolation methods from large volumes of whole blood to improve molecular diagnosis of bloodstream infections","volume":"8","author":"Loonen","year":"2013","journal-title":"PLoS One"},{"key":"10.1016\/j.mimet.2016.12.005_bb0145","doi-asserted-by":"crossref","first-page":"1687","DOI":"10.1007\/s10096-014-2153-4","article-title":"Developments for improved diagnosis of bacterial bloodstream infections","volume":"33","author":"Loonen","year":"2014","journal-title":"Eur. J. Clin. Microbiol. Infect. Dis."},{"key":"10.1016\/j.mimet.2016.12.005_bb0150","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1128\/CMR.00043-09","article-title":"The era of molecular and other non-culture-based methods in diagnosis of sepsis","volume":"23","author":"Mancini","year":"2010","journal-title":"Clin. Microbiol. Rev."},{"key":"10.1016\/j.mimet.2016.12.005_bb0155","doi-asserted-by":"crossref","first-page":"19207","DOI":"10.1073\/pnas.1008768107","article-title":"Electrical detection of pathogenic bacteria via immobilized antimicrobial peptides","volume":"107","author":"Mannoor","year":"2010","journal-title":"Proc. Natl. Acad. Sci. U. S. A."},{"key":"10.1016\/j.mimet.2016.12.005_bb0160","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/ncomms1767","article-title":"Graphene-based wireless bacteria detection on tooth enamel","volume":"3","author":"Mannoor","year":"2012","journal-title":"Nat. Commun."},{"key":"10.1016\/j.mimet.2016.12.005_bb0165","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1021\/ac2020728","article-title":"Novel phage amplified multichannel series piezoelectric quartz crystal sensor for rapid and sensitive detection of Mycobacterium tuberculosis","volume":"84","author":"Mi","year":"2012","journal-title":"Anal. Chem."},{"key":"10.1016\/j.mimet.2016.12.005_bb0170","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1128\/JCM.41.1.495-497.2003","article-title":"Detection and treatment of bloodstream infection: laboratory reporting and antimicrobial management","volume":"41","author":"Munson","year":"2003","journal-title":"J. Clin. Microbiol."},{"key":"10.1016\/j.mimet.2016.12.005_bb0180","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/S1473-3099(04)01205-8","article-title":"New developments in the diagnosis of bloodstream infections","volume":"4","author":"Peters","year":"2004","journal-title":"Lancet Infect. Dis."},{"key":"10.1016\/j.mimet.2016.12.005_bb0185","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1016\/j.ijantimicag.2004.09.005","article-title":"Antimicrobial peptides: premises and promises","volume":"24","author":"Reddy","year":"2004","journal-title":"Int. J. Antimicrob. Agents"},{"key":"10.1016\/j.mimet.2016.12.005_bb0195","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/j.snb.2009.12.006","article-title":"The construction and application of a new PPY-MSPQC for l-asparaginase activity assay","volume":"145","author":"Ren","year":"2010","journal-title":"Sensors Actuators B Chem."},{"key":"10.1016\/j.mimet.2016.12.005_bb0200","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/S0005-2736(02)00470-4","article-title":"Antibacterial peptide pleurocidin forms ion channels planar lipid bilayers","volume":"1564","author":"Saint","year":"2002","journal-title":"Biochim. Biophys. Acta"},{"key":"10.1016\/j.mimet.2016.12.005_bb0205","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/0003-2670(93)85042-I","article-title":"Behaviour of a series piezoelectric sensor in electrolyte solution: part I. Theory","volume":"276","author":"Shen","year":"1993","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.mimet.2016.12.005_bb0210","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.1099\/0022-1317-51-12-1090","article-title":"Comparison of 16S rDNA-based PCR and checkerboard DNA-DNA hybridisation for detection of selected endodontic pathogens","volume":"51","author":"Siqueira","year":"2002","journal-title":"J. Med. Microbiol."},{"key":"10.1016\/j.mimet.2016.12.005_bb0215","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1016\/j.bios.2008.08.008","article-title":"Nano-silver-modified PQC\/DNA biosensor for detecting E. coli in environmental water","volume":"24","author":"Sun","year":"2009","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.mimet.2016.12.005_bb0220","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1039\/C4NR05243A","article-title":"Carbon nanotube enhanced label-free detection of microRNAs based on hairpin probe triggered solid-phase rolling-circle amplification","volume":"7","author":"Tian","year":"2015","journal-title":"Nanoscale"},{"key":"10.1016\/j.mimet.2016.12.005_bb0225","doi-asserted-by":"crossref","first-page":"10415","DOI":"10.1021\/ac502926k","article-title":"Multichannel series piezoelectric quartz crystal cell sensor for real time and quantitative monitoring of the living cell and assessment of cytotoxicity","volume":"86","author":"Tong","year":"2014","journal-title":"Anal. Chem."},{"key":"10.1016\/j.mimet.2016.12.005_bb0230","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.aca.2014.09.050","article-title":"Immunosensor based on carbon nanotube\/manganese dioxide electrochemical tags","volume":"853","author":"Tu","year":"2015","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.mimet.2016.12.005_bb0235","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jinf.2007.10.001","article-title":"Bloodstream infections in adults: importance of healthcare-associated infections","volume":"56","author":"Vall\u00e9s","year":"2008","journal-title":"J. Infect."},{"key":"10.1016\/j.mimet.2016.12.005_bb0240","doi-asserted-by":"crossref","first-page":"4944","DOI":"10.1021\/ac303801v","article-title":"Catch and release: integrated system for multiplexed detection of bacteria","volume":"85","author":"Verbarg","year":"2013","journal-title":"Anal. Chem."},{"key":"10.1016\/j.mimet.2016.12.005_bb0245","doi-asserted-by":"crossref","first-page":"7816","DOI":"10.1021\/ac301445w","article-title":"Rapid, sensitive detection of neurotransmitters at microelectrodes modified with self-assembled SWCNT forests","volume":"84","author":"Xiao","year":"2012","journal-title":"Anal. Chem."},{"key":"10.1016\/j.mimet.2016.12.005_bb0250","first-page":"880","article-title":"Structure and bacterial cell selectivity of a fish-derived antimicrobial peptide, pleurocidin","volume":"16","author":"Yang","year":"2006","journal-title":"J. Microbiol. Biotechnol."},{"key":"10.1016\/j.mimet.2016.12.005_bb0255","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1124\/pr.55.1.2","article-title":"Mechanisms of antimicrobial peptide action and resistance","volume":"55","author":"Yeaman","year":"2003","journal-title":"Pharmacol. Rev."},{"key":"10.1016\/j.mimet.2016.12.005_bb0260","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1038\/415389a","article-title":"Antimicrobial peptides of multicellular organisms","volume":"415","author":"Zasloff","year":"2002","journal-title":"Nature"},{"key":"10.1016\/j.mimet.2016.12.005_bb0265","doi-asserted-by":"crossref","first-page":"9254","DOI":"10.1021\/ac101739b","article-title":"Real-time potentiometric detection of bacteria in complex samples","volume":"82","author":"Zelada-Guill\u00e9n","year":"2010","journal-title":"Anal. Chem."}],"container-title":["Journal of Microbiological Methods"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167701216303487?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167701216303487?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T23:54:39Z","timestamp":1759103679000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0167701216303487"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2]]},"references-count":49,"alternative-id":["S0167701216303487"],"URL":"https:\/\/doi.org\/10.1016\/j.mimet.2016.12.005","relation":{},"ISSN":["0167-7012"],"issn-type":[{"value":"0167-7012","type":"print"}],"subject":[],"published":{"date-parts":[[2017,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A novel method for the rapid detection of microbes in blood using pleurocidin antimicrobial peptide functionalized piezoelectric sensor","name":"articletitle","label":"Article Title"},{"value":"Journal of Microbiological Methods","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.mimet.2016.12.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}