{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T23:41:04Z","timestamp":1791848464739,"version":"4.3.4"},"reference-count":51,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Microbiological Methods"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1016\/j.mimet.2019.105728","type":"journal-article","created":{"date-parts":[[2019,10,17]],"date-time":"2019-10-17T11:25:22Z","timestamp":1571311522000},"page":"105728","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":27,"special_numbering":"C","title":["In vitro evaluation of the decontamination effect of cold atmospheric argon plasma on selected bacteria frequently encountered in small animal bite injuries"],"prefix":"10.1016","volume":"169","author":[{"given":"S.","family":"Winter","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Meyer-Lindenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Wolf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Reese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.C.","family":"Nolff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.mimet.2019.105728_bb0005","series-title":"From Antiseptics to Antibiotics - and Back? GMS Krankenhaushygiene Interdisziplinar 2, Doc26","author":"Assadian","year":"2007"},{"key":"10.1016\/j.mimet.2019.105728_bb0010","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1111\/j.1365-2672.2011.05198.x","article-title":"Induction of a viable-but-non-culturable state in bacteria treated with gas discharge plasma","volume":"112","author":"Brelles-Marino","year":"2012","journal-title":"J. Appl. Microbiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0015","doi-asserted-by":"crossref","first-page":"1248","DOI":"10.1016\/j.imbio.2013.04.015","article-title":"Impact of non-thermal plasma treatment on MAPK signaling pathways of human immune cell lines","volume":"218","author":"Bundscherer","year":"2013","journal-title":"Immunobiology"},{"key":"10.1016\/j.mimet.2019.105728_bb0020","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1111\/j.1365-2672.2010.04834.x","article-title":"Biological responses of bacillus stratosphericus to floating electrode-dielectric barrier discharge plasma treatment","volume":"109","author":"Cooper","year":"2010","journal-title":"J. Appl. Microbiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0025","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1016\/j.jhin.2011.03.019","article-title":"Disinfection of meticillin-resistant Staphylococcus aureus and Staphylococcus epidermidis biofilms using a remote non-thermal gas plasma","volume":"78","author":"Cotter","year":"2011","journal-title":"J. Hosp. Infect."},{"key":"10.1016\/j.mimet.2019.105728_bb0030","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1002\/ppap.200900059","article-title":"Antibacterial activity of an atmospheric pressure plasma jet against relevant wound pathogens in vitro on a simulated wound environment","volume":"7","author":"Daeschlein","year":"2010","journal-title":"Plasma Process. Polym."},{"key":"10.1016\/j.mimet.2019.105728_bb0035","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1002\/ppap.201100160","article-title":"In vitro susceptibility of important skin and wound pathogens against low temperature atmospheric pressure plasma jet (APPJ) and dielectric barrier discharge plasma (DBD)","volume":"9","author":"Daeschlein","year":"2012","journal-title":"Plasma Process. Polym."},{"key":"10.1016\/j.mimet.2019.105728_bb0040","first-page":"509","article-title":"Cold plasma is well-tolerated and does not disturb skin barrier or reduce skin moisture","volume":"10","author":"Daeschlein","year":"2012","journal-title":"JDDG"},{"key":"10.1016\/j.mimet.2019.105728_bb0045","first-page":"143","article-title":"Skin and wound decontamination of multidrug-resistant bacteria by cold atmospheric plasma coagulation","volume":"13","author":"Daeschlein","year":"2015","journal-title":"Journal der Deutschen Dermatologischen Gesellschaft = Journal of the German Society of Dermatology"},{"key":"10.1016\/j.mimet.2019.105728_bb0050","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/S0924-2244(97)01043-1","article-title":"Inimical processes: bacterial self-destruction and sub-lethal injury","volume":"8","author":"Dodd","year":"1997","journal-title":"Trends Food Sci. Technol."},{"key":"10.1016\/j.mimet.2019.105728_bb0055","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1099\/jmm.0.020263-0","article-title":"Bactericidal effects of non-thermal argon plasma in vitro, in biofilms and in the animal model of infected wounds","volume":"60","author":"Ermolaeva","year":"2011","journal-title":"J. Med. Microbiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0060","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1128\/mr.55.4.561-585.1991","article-title":"Oxidative stress responses in Escherichia coli and salmonella typhimurium","volume":"55","author":"Farr","year":"1991","journal-title":"Microbiol. Rev."},{"key":"10.1016\/j.mimet.2019.105728_bb0065","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.ijfoodmicro.2011.02.038","article-title":"Effect of microbial loading on the efficiency of cold atmospheric gas plasma inactivation of salmonella enterica serovar typhimurium","volume":"152","author":"Fernandez","year":"2012","journal-title":"Int. J. Food Microbiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0070","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1111\/j.1600-0625.2011.01411.x","article-title":"In vivo skin treatment with tissue-tolerable plasma influences skin physiology and antioxidant profile in human stratum corneum","volume":"21","author":"Fluhr","year":"2012","journal-title":"Exp. Dermatol."},{"key":"10.1016\/j.mimet.2019.105728_bb0075","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.ijantimicag.2015.02.026","article-title":"Bactericidal efficacy of atmospheric pressure non-thermal plasma (APNTP) against the ESKAPE pathogens","volume":"46","author":"Flynn","year":"2015","journal-title":"Int. J. Antimicrob. Agents"},{"key":"10.1016\/j.mimet.2019.105728_bb0080","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/S0257-8972(00)00803-3","article-title":"Sterilization and plasma processing of room temperature surfaces with a one atmosphere uniform glow discharge plasma (OAUGDP)","volume":"131","author":"Gadri","year":"2000","journal-title":"Surf. Coat. Technol."},{"key":"10.1016\/j.mimet.2019.105728_bb0085","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1109\/TPS.2006.878381","article-title":"Bactericidal action of the reactive species produced by gas-discharge nonthermal plasma at atmospheric pressure: a review","volume":"34","author":"Gaunt","year":"2006","journal-title":"IEEE Transac. on Plasma Sci."},{"key":"10.1016\/j.mimet.2019.105728_bb0090","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1159\/000314724","article-title":"Antiseptic efficacy and tolerance of tissue-tolerable plasma compared with two wound antiseptics on artificially bacterially contaminated eyes from commercially slaughtered pigs","volume":"23","author":"Hammann","year":"2010","journal-title":"Skin Pharmacol. Physiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0095","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1055\/s-2007-971165","article-title":"The effect of antimicrobial use on emergence and selection of resistance","volume":"42","author":"Harbarth","year":"2007","journal-title":"Anasthesiol. Intensivmed. Notfallmed. Schmerzther."},{"key":"10.1016\/j.mimet.2019.105728_bb0100","first-page":"1","article-title":"Plasma applications in medicine with a special focus on dermatology","volume":"25","author":"Heinlin","year":"2011","journal-title":"JEADV"},{"key":"10.1016\/j.mimet.2019.105728_bb0105","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1146\/annurev.micro.57.030502.090938","article-title":"Pathways of oxidative damage","volume":"57","author":"Imlay","year":"2003","journal-title":"Annu. Rev. Microbiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0110","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1099\/mic.0.021501-0","article-title":"Is Gas-Discharge Plasma a New Solution to the Old Problem of Biofilm Inactivation?","volume":"155","author":"Joaquin","year":"2009","journal-title":"Microbiology"},{"key":"10.1016\/j.mimet.2019.105728_bb0115","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.ajic.2009.11.002","article-title":"Control of methicillin-resistant Staphylococcus aureus in planktonic form and biofilms: a biocidal efficacy study of nonthermal dielectric-barrier discharge plasma","volume":"38","author":"Joshi","year":"2010","journal-title":"Am. J. Infect. Control"},{"key":"10.1016\/j.mimet.2019.105728_bb0120","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1128\/AAC.01002-10","article-title":"Nonthermal dielectric-barrier discharge plasma-induced inactivation involves oxidative DNA damage and membrane lipid peroxidation in Escherichia coli","volume":"55","author":"Joshi","year":"2011","journal-title":"Antimicrob. Agents Chemother."},{"key":"10.1016\/j.mimet.2019.105728_bb0125","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.mvr.2015.12.002","article-title":"Improvement of cutaneous microcirculation by cold atmospheric plasma (Besnard et al.): results of a controlled, prospective cohort study","volume":"104","author":"Kisch","year":"2016","journal-title":"Microvasc. Res."},{"key":"10.1016\/j.mimet.2019.105728_bb0130","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1111\/j.1600-051X.2011.01740.x","article-title":"Antimicrobial efficacy of non-thermal plasma in comparison to chlorhexidine against dental biofilms on titanium discs in vitro - proof of principle experiment","volume":"38","author":"Koban","year":"2011","journal-title":"J. Clin. Periodontol."},{"key":"10.1016\/j.mimet.2019.105728_bb0135","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1159\/000077241","article-title":"Influence of the antiseptic agents polyhexanide and octenidine on FL cells and on healing of experimental superficial aseptic wounds in piglets. A double-blind, randomised, stratified, controlled, parallel-group study","volume":"17","author":"Kramer","year":"2004","journal-title":"Skin Pharmacol. Physiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0140","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1159\/000335558","article-title":"Comparison of the antiseptic efficacy of tissue-tolerable plasma and an octenidine hydrochloride-based wound antiseptic on human skin","volume":"25","author":"Lademann","year":"2012","journal-title":"Skin Pharmacol. Physiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0145","doi-asserted-by":"crossref","first-page":"1409","DOI":"10.1109\/TPS.2002.804220","article-title":"Nonthermal decontamination of biological media by atmospheric-pressure plasmas: review, analysis, and prospects","volume":"30","author":"Laroussi","year":"2002","journal-title":"IEEE Transac. Plasma Sci."},{"key":"10.1016\/j.mimet.2019.105728_bb0150","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1109\/TPS.2009.2017267","article-title":"Low-temperature plasmas for medicine?","volume":"37","author":"Laroussi","year":"2009","journal-title":"IEEE Transac. on Plasma Sci."},{"key":"10.1016\/j.mimet.2019.105728_bb0155","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.ijms.2003.11.016","article-title":"Evaluation of the roles of reactive species, heat, and UV radiation in the inactivation of bacterial cells by air plasmas at atmospheric pressure","volume":"233","author":"Laroussi","year":"2004","journal-title":"Int. J. Mass Spectrom."},{"key":"10.1016\/j.mimet.2019.105728_bb0160","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1088\/1367-2630\/5\/1\/341","article-title":"Plasma interaction with microbes","volume":"5","author":"Laroussi","year":"2003","journal-title":"New J. Phys."},{"key":"10.1016\/j.mimet.2019.105728_bb0165","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1111\/j.1532-950X.1992.tb00025.x","article-title":"Effects of four preparations of 0.05% chlorhexidine diacetate on wound healing in dogs","volume":"21","author":"Lozier","year":"1992","journal-title":"Vet. Surg."},{"key":"10.1016\/j.mimet.2019.105728_bb0170","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1111\/jam.12426","article-title":"Bacterial inactivation by high-voltage atmospheric cold plasma: influence of process parameters and effects on cell leakage and DNA","volume":"116","author":"Lu","year":"2014","journal-title":"J. Appl. Microbiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0175","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.ijantimicag.2014.01.025","article-title":"Atmospheric pressure plasmas: infection control and bacterial responses","volume":"43","author":"Mai-Prochnow","year":"2014","journal-title":"Int. J. Antimicrob. Agents"},{"key":"10.1016\/j.mimet.2019.105728_bb0180","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1002\/ppap.201100133","article-title":"Antimicrobial efficacy of an atmospheric pressure plasma jet against biofilms of Pseudomonas aeruginosa and Staphylococcus epidermidis","volume":"10","author":"Matthes","year":"2013","journal-title":"Plasma Process. Polym."},{"key":"10.1016\/j.mimet.2019.105728_bb0185","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1159\/000353861","article-title":"Efficacy of different carrier gases for barrier discharge plasma generation compared to chlorhexidine on the survival of Pseudomonas aeruginosa embedded in biofilm in vitro","volume":"27","author":"Matthes","year":"2014","journal-title":"Skin Pharmacol. Physiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0190","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1159\/000443210","article-title":"Antibacterial activity of cold atmospheric pressure argon plasma against 78 genetically different (mecA, luk-P, agr or capsular polysaccharide type) Staphylococcus aureus strains","volume":"29","author":"Matthes","year":"2016","journal-title":"Skin Pharmacol. Physiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0195","doi-asserted-by":"crossref","first-page":"1304","DOI":"10.1109\/27.893321","article-title":"A note on the possible electrostatic disruption of bacteria","volume":"28","author":"Mendis","year":"2000","journal-title":"IEEE Transac. Plasma Sci."},{"key":"10.1016\/j.mimet.2019.105728_bb0200","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1109\/27.842860","article-title":"An overview of research using the one atmosphere uniform glow discharge plasma (OAUGDP) for sterilization of surfaces and materials","volume":"28","author":"Montie","year":"2000","journal-title":"IEEE Transac. Plasma Sci."},{"key":"10.1016\/j.mimet.2019.105728_bb0205","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1111\/jsap.12476","article-title":"Assessment of wound bio-burden and prevalence of multi-drug resistant bacteria during open wound management","volume":"57","author":"Nolff","year":"2016","journal-title":"J. Small Anim. Pract."},{"key":"10.1016\/j.mimet.2019.105728_bb0210","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/j.1476-4431.2005.00162.x","article-title":"Nosocomial infections and antimicrobial resistance in critical care medicine","volume":"16","author":"Ogeer-Gyles","year":"2006","journal-title":"J. Vet. Emerg. Crit. Care"},{"key":"10.1016\/j.mimet.2019.105728_bb0215","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1111\/j.1532-950X.1988.tb01019.x","article-title":"Effects of chlorhexidine diacetate and povidione-iodine on wound healing in dogs","volume":"17","author":"Sanchez","year":"1988","journal-title":"Vet. Surg."},{"key":"10.1016\/j.mimet.2019.105728_bb0220","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1002\/ppap.201400074","article-title":"Inactivation of biofilms using a low power atmospheric pressure argon plasma jet; the role of entrained nitrogen","volume":"12","author":"Taghizadeh","year":"2015","journal-title":"Plasma Process. Polym."},{"key":"10.1016\/j.mimet.2019.105728_bb0225","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1111\/1574-6976.12026","article-title":"Antimicrobial strategies centered around reactive oxygen species--bactericidal antibiotics, photodynamic therapy, and beyond","volume":"37","author":"Vatansever","year":"2013","journal-title":"FEMS Microbiol. Rev."},{"key":"10.1016\/j.mimet.2019.105728_bb0230","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.physrep.2013.05.005","article-title":"Plasmas for medicine","volume":"530","author":"Von Woedtke","year":"2013","journal-title":"Phys. Rep."},{"key":"10.1016\/j.mimet.2019.105728_bb0235","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3415\/VCOT-07-11-0106","article-title":"A review of multidrug resistant surgical site infections","volume":"21","author":"Weese","year":"2008","journal-title":"Vet. Comp. Orthopaedics Traumatol."},{"key":"10.1016\/j.mimet.2019.105728_bb0240","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1002\/cbin.10200","article-title":"Atmospheric pressure plasma jet treatment evokes transient oxidative stress in HaCaT keratinocytes and influences cell physiology","volume":"38","author":"Wende","year":"2014","journal-title":"Cell Biol. Int."},{"key":"10.1016\/j.mimet.2019.105728_bb0245","doi-asserted-by":"crossref","first-page":"73","DOI":"10.15654\/TPK-170713","article-title":"Comparison of the antibacterial efficacy of polyhexanide, cold atmospheric argon plasma and saline in the treatment of canine bite wounds","volume":"46","author":"Winter","year":"2018","journal-title":"Tier\u00e4rztliche Praxis. Ausgabe K, Kleintiere\/Heimtiere"},{"key":"10.1016\/j.mimet.2019.105728_bb0250","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1111\/j.1365-2672.2006.03033.x","article-title":"Effects of cell surface loading and phase of growth in cold atmospheric gas plasma inactivation of Escherichia coli K12","volume":"101","author":"Yu","year":"2006","journal-title":"J. Appl. Microbiol."},{"key":"10.1016\/j.mimet.2019.105728_bb0255","doi-asserted-by":"crossref","first-page":"203701","DOI":"10.1063\/1.4807133","article-title":"A study of oxidative stress induced by non-thermal plasma-activated water for bacterial damage","volume":"102","author":"Zhang","year":"2013","journal-title":"Appl. Phys. Lett."}],"container-title":["Journal of Microbiological Methods"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167701219307444?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167701219307444?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T00:00:06Z","timestamp":1759104006000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0167701219307444"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":51,"alternative-id":["S0167701219307444"],"URL":"https:\/\/doi.org\/10.1016\/j.mimet.2019.105728","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/353821","asserted-by":"object"}]},"ISSN":["0167-7012"],"issn-type":[{"value":"0167-7012","type":"print"}],"subject":[],"published":{"date-parts":[[2020,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"In vitro evaluation of the decontamination effect of cold atmospheric argon plasma on selected bacteria frequently encountered in small animal bite injuries","name":"articletitle","label":"Article Title"},{"value":"Journal of Microbiological Methods","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.mimet.2019.105728","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"105728"}}