{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T00:20:09Z","timestamp":1759882809912,"version":"build-2065373602"},"reference-count":17,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2020,7,1]],"date-time":"2020-07-01T00:00:00Z","timestamp":1593561600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,7,1]],"date-time":"2020-07-01T00:00:00Z","timestamp":1593561600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Medical Journal Armed Forces India"],"published-print":{"date-parts":[[2020,7]]},"DOI":"10.1016\/j.mjafi.2018.03.001","type":"journal-article","created":{"date-parts":[[2020,7,24]],"date-time":"2020-07-24T08:19:16Z","timestamp":1595578756000},"page":"333-337","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Thermal stress inside a disabled submarine"],"prefix":"10.1016","volume":"76","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3646-5614","authenticated-orcid":false,"given":"Sourabh","family":"Bhutani","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Imran","family":"Khan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdul","family":"Nasser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.S.","family":"Saxena","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.mjafi.2018.03.001_bib0090","first-page":"138","article-title":"Atmospheric changes and physiological responses during a 6-day \u201cdisabled submarine\u201d exercise","volume":"75","author":"Risberg","year":"2004","journal-title":"Aviat Sp Environ Med"},{"issue":"4","key":"10.1016\/j.mjafi.2018.03.001_bib0095","first-page":"175","article-title":"Findings from a simulated disabled submarine survival trial","volume":"27","author":"House","year":"2000","journal-title":"Undersea Hyperb Med"},{"issue":"March","key":"10.1016\/j.mjafi.2018.03.001_bib0100","first-page":"1","article-title":"Exercise tests disabled submarine survival","author":"Horn","year":"2003","journal-title":"Undersea Warf"},{"key":"10.1016\/j.mjafi.2018.03.001_bib0105","series-title":"UHMS Meeting Abstracts [Internet]","article-title":"DISSUB trial for the evaluation of USN Battelle Curtains in Republic of Singapore Navy","author":"Chern","year":"2005"},{"key":"10.1016\/j.mjafi.2018.03.001_bib0110","series-title":"Proceedings of the XXVIII Annual Conference of the Marine Medical Society","first-page":"36","article-title":"A review of international submarine accidents","author":"Bhutani","year":"2012"},{"year":"2002","series-title":"Estimated Carbon Dioxide Production and Physiological Adaptation of Survivors in a Simulated Disabled Submarine. Groton, CT","author":"Francis","key":"10.1016\/j.mjafi.2018.03.001_bib0115"},{"key":"10.1016\/j.mjafi.2018.03.001_bib0120","unstructured":"Submarine Safety SUBSAFE [Internet]. p. 1\u20135. Available from: http:\/\/www.globalsecurity.org\/military\/systems\/ship\/systems\/subsafe.htm [cited 24.02.13]."},{"year":"2009","series-title":"Disabled Submarine Heat Stress Conference [Internet]. Groton","author":"Horn","key":"10.1016\/j.mjafi.2018.03.001_bib0125"},{"issue":"5","key":"10.1016\/j.mjafi.2018.03.001_bib0130","doi-asserted-by":"crossref","first-page":"1731","DOI":"10.1152\/jappl.1998.84.5.1731","article-title":"Heat acclimation, aerobic fitness, and hydration effects on tolerance during uncompensable heat stress","volume":"84","author":"Cheung","year":"1998","journal-title":"J Appl Physiol"},{"year":"1998","series-title":"The Thermophysiology of Uncompensable Heat Stress: Influence of Hydration Status, Fluid Replacement, Aerobic Training, Physical Fitness, and Heat Acclimation","author":"Cheung","key":"10.1016\/j.mjafi.2018.03.001_bib0135"},{"issue":"5","key":"10.1016\/j.mjafi.2018.03.001_bib0140","doi-asserted-by":"crossref","first-page":"329","DOI":"10.2165\/00007256-200029050-00004","article-title":"The thermophysiology of uncompensable heat stress. Physiological manipulations and individual characteristics","volume":"29","author":"Cheung","year":"2000","journal-title":"Sport Med"},{"issue":"2","key":"10.1016\/j.mjafi.2018.03.001_bib0145","doi-asserted-by":"crossref","first-page":"112","DOI":"10.3357\/ASEM.3787.2014","article-title":"Increasing relative humidity impacts low-intensity exercise in the heat","volume":"85","author":"Moyen","year":"2014","journal-title":"Aviat Sp Environ Med"},{"issue":"4","key":"10.1016\/j.mjafi.2018.03.001_bib0150","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1111\/j.1748-1716.2010.02119.x","article-title":"Cardiovascular function in heat-stressed human","volume":"199","author":"Crandall","year":"2010","journal-title":"Acta Physiol"},{"issue":"2 suppl","key":"10.1016\/j.mjafi.2018.03.001_bib0155","doi-asserted-by":"crossref","first-page":"564S","DOI":"10.1093\/ajcn\/72.2.564S","article-title":"Fluid and electrolyte supplementation for exercise heat stress","volume":"72","author":"Sawka","year":"2000","journal-title":"Am J Clin Nutr [Internet]"},{"issue":"January","key":"10.1016\/j.mjafi.2018.03.001_bib0160","first-page":"372","article-title":"The impact of different environmental conditions on cognitive function: a focused review","volume":"6","author":"Taylor","year":"2015","journal-title":"Front Physiol [Internet]"},{"key":"10.1016\/j.mjafi.2018.03.001_bib0165","series-title":"Diving and Subaquatic Medicine","first-page":"138","article-title":"Decompression sickness","author":"Robyn","year":"2002"},{"issue":"6","key":"10.1016\/j.mjafi.2018.03.001_bib0170","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.jtherbio.2013.03.010","article-title":"Extremity cooling for heat stress mitigation in military and occupational settings","volume":"38","author":"DeGroot","year":"2013","journal-title":"J Therm Biol"}],"container-title":["Medical Journal Armed Forces India"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0377123718300236?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0377123718300236?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T11:49:53Z","timestamp":1759837793000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0377123718300236"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,7]]}},"alternative-id":["S0377123718300236"],"URL":"https:\/\/doi.org\/10.1016\/j.mjafi.2018.03.001","relation":{},"ISSN":["0377-1237"],"issn-type":[{"type":"print","value":"0377-1237"}],"subject":[],"published":{"date-parts":[[2020,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Thermal stress inside a disabled submarine","name":"articletitle","label":"Article Title"},{"value":"Medical Journal Armed Forces India","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.mjafi.2018.03.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Published by Elsevier B.V. on behalf of Director General, Armed Forces Medical Services.","name":"copyright","label":"Copyright"}]}}