{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T12:31:46Z","timestamp":1791117106825,"version":"4.1.0"},"reference-count":30,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2009,5,1]],"date-time":"2009-05-01T00:00:00Z","timestamp":1241136000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2009,5,1]],"date-time":"2009-05-01T00:00:00Z","timestamp":1241136000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["FOR 474"],"award-info":[{"award-number":["FOR 474"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2009,5]]},"DOI":"10.1016\/j.mri.2008.08.010","type":"journal-article","created":{"date-parts":[[2008,10,18]],"date-time":"2008-10-18T04:54:07Z","timestamp":1224305647000},"page":"549-556","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":28,"title":["Comparison of magnetic resonance imaging of inhaled SF6 with respiratory gas analysis"],"prefix":"10.1016","volume":"27","author":[{"given":"Alexander-Wigbert","family":"Scholz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ursula","family":"Wolf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Fabel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norbert","family":"Weiler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claus P.","family":"Heussel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Balthasar","family":"Eberle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"David","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wolfgang G.","family":"Schreiber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.mri.2008.08.010_bib1","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1152\/japplphysiol.00732.2006","article-title":"Physiological imaging of the lung: single-photon-emission computed tomography (SPECT)","volume":"102","author":"Petersson","year":"2007","journal-title":"J Appl Physiol"},{"key":"10.1016\/j.mri.2008.08.010_bib2","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1152\/japplphysiol.00763.2006","article-title":"Visualizing lung function with positron emission tomography","volume":"102","author":"Harris","year":"2007","journal-title":"J Appl Physiol"},{"key":"10.1016\/j.mri.2008.08.010_bib3","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.ccm.2007.12.003","article-title":"Functional imaging: CT and MRI","volume":"29","author":"Van Beek","year":"2008","journal-title":"Clin Chest Med"},{"key":"10.1016\/j.mri.2008.08.010_bib4","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1097\/00004424-200502000-00005","article-title":"Feasibility of pulmonary ventilation visualization with aerosolized magnetic resonance contrast media","volume":"40","author":"Haage","year":"2005","journal-title":"Invest Radiol"},{"key":"10.1016\/j.mri.2008.08.010_bib5","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1038\/nm1196-1236","article-title":"Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging","volume":"2","author":"Edelman","year":"1996","journal-title":"Nat Med"},{"key":"10.1016\/j.mri.2008.08.010_bib6","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1002\/mrm.20051","article-title":"Assessment of human pulmonary function using oxygen-enhanced T1 imaging in patients with cystic fibrosis","volume":"51","author":"Jakob","year":"2004","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2008.08.010_bib7","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/S0720-048X(00)00298-9","article-title":"Pulmonary ventilation: dynamic MRI with inhalation of molecular oxygen","volume":"37","author":"Hatabu","year":"2001","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.mri.2008.08.010_bib8","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1007\/s10334-004-0034-z","article-title":"Imaging lung function using rapid dynamic acquisition of T1-maps during oxygen enhancement","volume":"16","author":"Arnold","year":"2004","journal-title":"MAGMA"},{"key":"10.1016\/j.mri.2008.08.010_bib9","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1002\/mrm.20570","article-title":"Improved quantitative dynamic regional oxygen-enhanced pulmonary imaging using image registration","volume":"54","author":"Naish","year":"2005","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2008.08.010_bib10","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1186\/1465-9921-7-106","article-title":"Magnetic resonance lung function \u2014 a breakthrough for lung imaging and functional assessment? A phantom study and clinical trial","volume":"7","author":"Zapke","year":"2006","journal-title":"Respir Res"},{"key":"10.1016\/j.mri.2008.08.010_bib11","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1038\/370199a0","article-title":"Biological magnetic resonance imaging using laser-polarized 129Xe","volume":"370","author":"Albert","year":"1994","journal-title":"Nature"},{"key":"10.1016\/j.mri.2008.08.010_bib12","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1148\/radiology.200.2.8685356","article-title":"Human lung air spaces: potential for MR imaging with hyperpolarized He-3","volume":"200","author":"MacFall","year":"1996","journal-title":"Radiology"},{"key":"10.1016\/j.mri.2008.08.010_bib13","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1002\/1099-1492(200006)13:4<176::AID-NBM640>3.0.CO;2-I","article-title":"Dynamic echo planar MR imaging of lung ventilation with hyperpolarized 3He in normal subjects and patients with severe emphysema","volume":"13","author":"Gierada","year":"2000","journal-title":"NMR Biomed"},{"key":"10.1016\/j.mri.2008.08.010_bib14","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1002\/1099-1492(200006)13:4<182::AID-NBM642>3.0.CO;2-N","article-title":"3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes","volume":"13","author":"Guenther","year":"2000","journal-title":"NMR Biomed"},{"key":"10.1016\/j.mri.2008.08.010_bib15","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1067\/mai.2003.1544","article-title":"Imaging the lungs in asthmatic patients by using hyperpolarized helium-3 magnetic resonance: assessment of response to methacholine and exercise challenge","volume":"111","author":"Samee","year":"2003","journal-title":"J Allergy Clin Immunol"},{"key":"10.1016\/j.mri.2008.08.010_bib16","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1007\/s00330-003-2092-4","article-title":"3He-MRI in follow-up of lung transplant recipients","volume":"14","author":"Gast","year":"2004","journal-title":"Eur Radiol"},{"key":"10.1016\/j.mri.2008.08.010_bib17","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1002\/mrm.10206","article-title":"Quantitative measurement of regional lung ventilation using 3He MRI","volume":"48","author":"Deninger","year":"2002","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2008.08.010_bib18","doi-asserted-by":"crossref","first-page":"2259","DOI":"10.1152\/japplphysiol.00245.2004","article-title":"3He MRI-based assessment of posture-dependent regional ventilation gradients in rats","volume":"98","author":"Mansson","year":"2005","journal-title":"J Appl Physiol"},{"key":"10.1016\/j.mri.2008.08.010_bib19","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1002\/mrm.21288","article-title":"MR grid-tagging using hyperpolarized helium-3 for regional quantitative assessment of pulmonary biomechanics and ventilation","volume":"58","author":"Cai","year":"2007","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2008.08.010_bib20","doi-asserted-by":"crossref","first-page":"2279","DOI":"10.1152\/jappl.2000.88.6.2279","article-title":"Imaging obstructed ventilation with NMR using inert fluorinated gases","volume":"88","author":"Kuethe","year":"2000","journal-title":"J Appl Physiol"},{"key":"10.1016\/j.mri.2008.08.010_bib21","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1055\/s-2000-3750","article-title":"Breathhold 19F-magnetic resonance imaging of lung ventilation using SF6 gas","volume":"172","author":"Schreiber","year":"2000","journal-title":"Rofo"},{"key":"10.1016\/j.mri.2008.08.010_bib22","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1002\/mrm.1082","article-title":"Dynamic 19F-MRI of pulmonary ventilation using sulfur hexafluoride (SF6) gas","volume":"45","author":"Schreiber","year":"2001","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2008.08.010_bib23","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1002\/mrm.10245","article-title":"Volume of rat lungs measured throughout the respiratory cycle using 19F NMR of the inert gas SF6","volume":"48","author":"Kuethe","year":"2002","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2008.08.010_bib24","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1002\/mrm.20632","article-title":"19F MR imaging of ventilation and diffusion in excised lungs","volume":"54","author":"Jacob","year":"2005","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2008.08.010_bib25","doi-asserted-by":"crossref","first-page":"948","DOI":"10.1002\/mrm.20859","article-title":"Subsecond fluorine-19 MRI of the lung","volume":"55","author":"Wolf","year":"2006","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2008.08.010_bib26","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1002\/mrm.1910340618","article-title":"The Rician distribution of noisy MRI data","volume":"34","author":"Gudbjartsson","year":"1995","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2008.08.010_bib27","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2165\/00007256-200030010-00001","article-title":"Measures of reliability in sports medicine and science","volume":"30","author":"Hopkins","year":"2000","journal-title":"Sports Med"},{"key":"10.1016\/j.mri.2008.08.010_bib28","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1177\/096228029900800204","article-title":"Measuring agreement in method comparison studies","volume":"8","author":"Bland","year":"1999","journal-title":"Stat Methods Med Res"},{"key":"10.1016\/j.mri.2008.08.010_bib29","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1152\/jappl.1967.22.4.675","article-title":"Time-dependent variations of pulmonary gas exchange in normal man at rest","volume":"22","author":"Lenfant","year":"1967","journal-title":"J Appl Physiol"},{"key":"10.1016\/j.mri.2008.08.010_bib30","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1152\/jappl.1978.45.4.512","article-title":"VA\/Q inhomogeneity and AaDO2 in man during exercise: effect of SF6 breathing","volume":"45","author":"Gledhill","year":"1978","journal-title":"J Appl Physiol"}],"container-title":["Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0730725X08002968?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0730725X08002968?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T08:27:38Z","timestamp":1759998458000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0730725X08002968"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,5]]},"references-count":30,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2009,5]]}},"alternative-id":["S0730725X08002968"],"URL":"https:\/\/doi.org\/10.1016\/j.mri.2008.08.010","relation":{},"ISSN":["0730-725X"],"issn-type":[{"value":"0730-725X","type":"print"}],"subject":[],"published":{"date-parts":[[2009,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of magnetic resonance imaging of inhaled SF6 with respiratory gas analysis","name":"articletitle","label":"Article Title"},{"value":"Magnetic Resonance Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.mri.2008.08.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2009 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}