{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T05:33:18Z","timestamp":1776663198880,"version":"3.51.2"},"reference-count":18,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,12,1]],"date-time":"2017-12-01T00:00:00Z","timestamp":1512086400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["EB001981"],"award-info":[{"award-number":["EB001981"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002949","name":"Jiangsu Province","doi-asserted-by":"publisher","award":["BL2012044"],"award-info":[{"award-number":["BL2012044"]}],"id":[{"id":"10.13039\/501100002949","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2017,12]]},"DOI":"10.1016\/j.mri.2017.08.009","type":"journal-article","created":{"date-parts":[[2017,9,1]],"date-time":"2017-09-01T16:39:38Z","timestamp":1504283978000},"page":"92-95","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"special_numbering":"C","title":["Static and dynamic liver stiffness: An ex vivo porcine liver study using MR elastography"],"prefix":"10.1016","volume":"44","author":[{"given":"Chun","family":"Yang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meng","family":"Yin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kevin J.","family":"Glaser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiangyang","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kai","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard L.","family":"Ehman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.mri.2017.08.009_bb0005","doi-asserted-by":"crossref","first-page":"1854","DOI":"10.1126\/science.7569924","article-title":"Magnetic resonance elastography by direct visualization of propagating acoustic strain waves","volume":"269","author":"Muthupillai","year":"1995","journal-title":"Science"},{"key":"10.1016\/j.mri.2017.08.009_bb0010","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1007\/s00247-011-2298-6","article-title":"Pediatric MR elastography of hepatic fibrosis: principles, technique and early clinical experience","volume":"42","author":"Binkovitz","year":"2012","journal-title":"Pediatr Radiol"},{"key":"10.1016\/j.mri.2017.08.009_bb0015","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1016\/j.cgh.2007.06.012","article-title":"Assessment of hepatic fibrosis with magnetic resonance elastography","volume":"5","author":"Yin","year":"2007","journal-title":"Clin Gastroenterol Hepatol"},{"key":"10.1016\/j.mri.2017.08.009_bb0020","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1053\/j.gastro.2008.03.076","article-title":"Magnetic resonance elastography for the noninvasive staging of liver fibrosis","volume":"135","author":"Huwart","year":"2008","journal-title":"Gastroenterology"},{"key":"10.1016\/j.mri.2017.08.009_bb0025","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1002\/hep.23312","article-title":"Diagnosis of fibrosis and cirrhosis using liver stiffness measurement in nonalcoholic fatty liver disease","volume":"51","author":"Wong","year":"2010","journal-title":"Hepatology"},{"key":"10.1016\/j.mri.2017.08.009_bb0030","first-page":"469","article-title":"Fibrosis staging in chronic hepatitis C: analysis of discordance between transient elastography and liver biopsy","volume":"17","author":"Calvaruso","year":"2010","journal-title":"J Viral Hepat"},{"key":"10.1016\/j.mri.2017.08.009_bb0035","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1002\/hep.22007","article-title":"Acute viral hepatitis increases liver stiffness values measured by transient elastography","volume":"47","author":"Arena","year":"2008","journal-title":"Hepatology"},{"key":"10.1016\/j.mri.2017.08.009_bb0040","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1002\/hep.22056","article-title":"Transient elastography is unreliable for detection of cirrhosis in patients with acute liver damage","volume":"47","author":"Sagir","year":"2008","journal-title":"Hepatology"},{"key":"10.1016\/j.mri.2017.08.009_bb0045","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1111\/j.1872-034X.2009.00553.x","article-title":"New insights into the pathobiology of portal hypertension","volume":"39","author":"Guturu","year":"2009","journal-title":"Hepatol Res"},{"key":"10.1016\/j.mri.2017.08.009_bb0050","doi-asserted-by":"crossref","first-page":"64","DOI":"10.2214\/AJR.10.5989","article-title":"Dynamic postprandial hepatic stiffness augmentation assessed with MR elastography in patients with chronic liver disease","volume":"197","author":"Yin","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.mri.2017.08.009_bb0055","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1002\/jmri.24496","article-title":"Relationship of MR elastography determined liver stiffness with cardiac function after Fontan palliation","volume":"40","author":"Wallihan","year":"2014","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.mri.2017.08.009_bb0060","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1111\/chd.12144","article-title":"Magnetic resonance elastography of the liver in patients status-post fontan procedure: feasibility and preliminary results","volume":"9","author":"Serai","year":"2014","journal-title":"Congenit Heart Dis"},{"key":"10.1016\/j.mri.2017.08.009_bb0065","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1002\/jmri.24049","article-title":"Hepatic and splenic stiffness augmentation assessed with MR elastography in an in vivo porcine portal hypertension model","volume":"38","author":"Yin","year":"2013","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.mri.2017.08.009_bb0070","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1002\/jmri.22610","article-title":"Portal hypertension correlates with splenic stiffness as measured with MR elastography","volume":"34","author":"Nedredal","year":"2011","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.mri.2017.08.009_bb0075","doi-asserted-by":"crossref","first-page":"122","DOI":"10.2214\/AJR.07.3504","article-title":"Feasibility of in vivo MR elastographic splenic stiffness measurements in the assessment of portal hypertension","volume":"193","author":"Talwalkar","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.mri.2017.08.009_bb0080","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1002\/jmri.24165","article-title":"Towards compression-sensitive magnetic resonance elastography of the liver: sensitivity of harmonic volumetric strain to portal hypertension","volume":"39","author":"Hirsch","year":"2014","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.mri.2017.08.009_bb0085","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.mri.2011.09.009","article-title":"Assessment of stiffness changes in the ex vivo porcine aortic wall using magnetic resonance elastography","volume":"30","author":"Xu","year":"2012","journal-title":"Magn Reson Imaging"},{"key":"10.1016\/j.mri.2017.08.009_bb0090","doi-asserted-by":"crossref","first-page":"178","DOI":"10.7150\/jca.1.178","article-title":"Elevated pressure improves the rate of formalin penetration while preserving tissue morphology","volume":"1","author":"Chesnick","year":"2010","journal-title":"J Cancer"}],"container-title":["Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0730725X1730173X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0730725X1730173X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,7]],"date-time":"2018-09-07T03:36:38Z","timestamp":1536291398000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0730725X1730173X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12]]},"references-count":18,"alternative-id":["S0730725X1730173X"],"URL":"https:\/\/doi.org\/10.1016\/j.mri.2017.08.009","relation":{},"ISSN":["0730-725X"],"issn-type":[{"value":"0730-725X","type":"print"}],"subject":[],"published":{"date-parts":[[2017,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Static and dynamic liver stiffness: An ex vivo porcine liver study using MR elastography","name":"articletitle","label":"Article Title"},{"value":"Magnetic Resonance Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.mri.2017.08.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}