{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T10:45:35Z","timestamp":1772102735063,"version":"3.50.1"},"reference-count":40,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100004830","name":"Siemens","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004830","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000801","name":"Bayer Healthcare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000801","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1016\/j.mri.2020.10.016","type":"journal-article","created":{"date-parts":[[2020,11,3]],"date-time":"2020-11-03T23:27:08Z","timestamp":1604446028000},"page":"17-25","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"special_numbering":"C","title":["Non-contrast-enhanced MR-angiography (MRA) of lower extremity peripheral arterial disease at 3\u00a0tesla: Examination time and diagnostic performance of 2D quiescent-interval single-shot MRA vs. 3D fast spin-Echo MRA"],"prefix":"10.1016","volume":"76","author":[{"given":"Gesine","family":"Knobloch","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marie-Teres","family":"Lauff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Moritz","family":"Hanke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carsten","family":"Schwenke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernd","family":"Hamm","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Moritz","family":"Wagner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.mri.2020.10.016_bb0005","article-title":"2016 AHA\/ACC guideline on the management of patients with lower extremity peripheral artery disease: a report of the American College of Cardiology\/American Heart Association task force on clinical practice guidelines","volume":"135","author":"Gerhard-Herman","year":"2017","journal-title":"Circulation."},{"key":"10.1016\/j.mri.2020.10.016_bb0010","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1093\/eurheartj\/ehx095","volume":"39","author":"Aboyans","year":"2018","journal-title":"Eur. Heart J."},{"key":"10.1016\/j.mri.2020.10.016_bb0015","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1161\/CIRCRESAHA.116.303849","article-title":"Epidemiology of peripheral artery disease","volume":"116","author":"Criqui","year":"2015","journal-title":"Circ. Res."},{"key":"10.1016\/j.mri.2020.10.016_bb0020","doi-asserted-by":"crossref","DOI":"10.1007\/s00234-020-02434-8","article-title":"Exposure to gadolinium and neurotoxicity: current status of preclinical and clinical studies","author":"Mallio","year":"2020","journal-title":"Neuroradiology."},{"key":"10.1016\/j.mri.2020.10.016_bb0025","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1148\/rg.291085072","article-title":"MR imaging in patients at risk for developing nephrogenic systemic fibrosis: protocols, practices, and imaging techniques to maximize patient safety","volume":"29","author":"Juluru","year":"2009","journal-title":"Radiographics"},{"key":"10.1016\/j.mri.2020.10.016_bb0030","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1148\/radiol.2481071497","article-title":"Nonenhanced MR angiography","volume":"248","author":"Miyazaki","year":"2008","journal-title":"Radiology."},{"key":"10.1016\/j.mri.2020.10.016_bb0035","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1161\/CIRCIMAGING.111.970814","article-title":"Multimodality imaging of lower extremity peripheral arterial disease: current role and future directions","volume":"5","author":"Pollak","year":"2012","journal-title":"Circ. Cardiovasc. Imag."},{"key":"10.1016\/j.mri.2020.10.016_bb0040","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.2214\/AJR.12.8730","article-title":"Unenhanced 3D turbo spin-echo MR angiography of lower limbs in peripheral arterial disease: a comparative study with gadolinium-enhanced MR angiography","volume":"200","author":"Diop","year":"2013","journal-title":"AJR Am. J. Roentgenol."},{"key":"10.1016\/j.mri.2020.10.016_bb0045","doi-asserted-by":"crossref","first-page":"1979","DOI":"10.1007\/s00330-011-2132-4","article-title":"ECG-triggered non-contrast-enhanced MR angiography (TRANCE) versus digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease of the lower extremities","volume":"21","author":"Gutzeit","year":"2011","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.mri.2020.10.016_bb0050","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s10334-012-0352-5","article-title":"ECG-triggered non-enhanced MR angiography of peripheral arteries in comparison to DSA in patients with peripheral artery occlusive disease","volume":"26","author":"Partovi","year":"2013","journal-title":"Magma."},{"key":"10.1016\/j.mri.2020.10.016_bb0055","doi-asserted-by":"crossref","first-page":"2871","DOI":"10.1007\/s00330-015-4089-1","article-title":"3D non-contrast-enhanced ECG-gated MR angiography of the lower extremities with dual-source radiofrequency transmission at 3.0 T: Intraindividual comparison with contrast-enhanced MR angiography in PAOD patients","volume":"26","author":"Rasper","year":"2016","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.mri.2020.10.016_bb0060","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1002\/jmri.24124","article-title":"Comparison of quiescent inflow single-shot and native space for nonenhanced peripheral MR angiography","volume":"38","author":"Ward","year":"2013","journal-title":"J. Magn. Reson. Imag."},{"key":"10.1016\/j.mri.2020.10.016_bb0065","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1007\/s00330-010-1932-2","article-title":"High-resolution 3D non-contrast-enhanced, ECG-gated, multi-step MR angiography of the lower extremities: comparison with contrast-enhanced MR angiography","volume":"21","author":"Mohrs","year":"2011","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.mri.2020.10.016_bb0070","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.crad.2017.12.003","article-title":"Advances in non-contrast quiescent-interval slice-selective (QISS) magnetic resonance angiography","volume":"74","author":"Edelman","year":"2019","journal-title":"Clin. Radiol."},{"key":"10.1016\/j.mri.2020.10.016_bb0075","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1097\/RLI.0000000000000592","article-title":"Free-breathing fast low-angle shot quiescent-interval slice-selective magnetic resonance angiography for improved detection of vascular Stenoses in the pelvis and abdomen: technical development","volume":"54","author":"Varga-Szemes","year":"2019","journal-title":"Investig. Radiol."},{"key":"10.1016\/j.mri.2020.10.016_bb0080","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1002\/mrm.22287","article-title":"Quiescent-interval single-shot unenhanced magnetic resonance angiography of peripheral vascular disease: technical considerations and clinical feasibility","volume":"63","author":"Edelman","year":"2010","journal-title":"Magn. Reson. Med."},{"key":"10.1016\/j.mri.2020.10.016_bb0085","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1148\/radiol.11101336","article-title":"Evaluation of peripheral arterial disease with nonenhanced quiescent-interval single-shot MR angiography","volume":"260","author":"Hodnett","year":"2011","journal-title":"Radiology."},{"key":"10.1016\/j.mri.2020.10.016_bb0090","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.crad.2011.10.014","article-title":"Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: comparison with contrast-enhanced MRA","volume":"67","author":"Klasen","year":"2012","journal-title":"Clin. Radiol."},{"key":"10.1016\/j.mri.2020.10.016_bb0095","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0091078","article-title":"Non-contrast-enhanced MR angiography at 3 tesla in patients with advanced peripheral arterial occlusive disease","volume":"9","author":"Thierfelder","year":"2014","journal-title":"PLoS One"},{"key":"10.1016\/j.mri.2020.10.016_bb0100","doi-asserted-by":"crossref","first-page":"886","DOI":"10.2214\/AJR.13.11243","article-title":"Evaluating peripheral arterial disease with unenhanced quiescent-interval single-shot MR angiography at 3 T","volume":"202","author":"Amin","year":"2014","journal-title":"AJR Am. J. Roentgenol."},{"key":"10.1016\/j.mri.2020.10.016_bb0105","doi-asserted-by":"crossref","first-page":"1486","DOI":"10.1002\/jmri.24324","article-title":"Nonenhanced ECG-gated quiescent-interval single shot MRA: image quality and stenosis assessment at 3 tesla compared with contrast-enhanced MRA and digital subtraction angiography","volume":"39","author":"Hansmann","year":"2014","journal-title":"J. Magn. Reson. Imag."},{"key":"10.1016\/j.mri.2020.10.016_bb0110","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.2214\/AJR.10.6091","article-title":"Peripheral arterial disease in a symptomatic diabetic population: prospective comparison of rapid unenhanced MR angiography (MRA) with contrast-enhanced MRA","volume":"197","author":"Hodnett","year":"2011","journal-title":"AJR Am. J. Roentgenol."},{"key":"10.1016\/j.mri.2020.10.016_bb0115","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.crad.2013.12.006","article-title":"ECG-gated quiescent-interval single-shot MR angiography of the lower extremities: initial experience at 3 T","volume":"69","author":"Knobloch","year":"2014","journal-title":"Clin. Radiol."},{"key":"10.1016\/j.mri.2020.10.016_bb0120","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1007\/s10554-015-0612-3","article-title":"Nonenhanced peripheral MR-angiography (MRA) at 3 tesla: evaluation of quiescent-interval single-shot MRA in patients undergoing digital subtraction angiography","volume":"31","author":"Wagner","year":"2015","journal-title":"Int. J. Card. Imaging"},{"key":"10.1016\/j.mri.2020.10.016_bb0125","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1002\/jmri.24174","article-title":"Technical considerations in MR angiography: an image-based guide","volume":"37","author":"Morelli","year":"2013","journal-title":"J. Magn. Reson. Imag."},{"key":"10.1016\/j.mri.2020.10.016_bb0130","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1038\/ncpcardio1035","article-title":"Technology insight: magnetic resonance angiography for the evaluation of patients with peripheral artery disease","volume":"4","author":"Dellegrottaglie","year":"2007","journal-title":"Nat. Clin. Pract. Cardiovasc. Med."},{"key":"10.1016\/j.mri.2020.10.016_bb0135","doi-asserted-by":"crossref","first-page":"325","DOI":"10.7326\/0003-4819-153-5-201009070-00007","article-title":"Meta-analysis: accuracy of contrast-enhanced magnetic resonance angiography for assessing steno-occlusions in peripheral arterial disease","volume":"153","author":"Menke","year":"2010","journal-title":"Ann. Intern. Med."},{"key":"10.1016\/j.mri.2020.10.016_bb0140","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1148\/radiol.2273020227","article-title":"Peripheral MR angiography: separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-Echo imaging","volume":"227","author":"Miyazaki","year":"2003","journal-title":"Radiology."},{"key":"10.1016\/j.mri.2020.10.016_bb0145","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1002\/jmri.21416","article-title":"3D nongadolinium-enhanced ECG-gated MRA of the distal lower extremities: preliminary clinical experience","volume":"28","author":"Lim","year":"2008","journal-title":"J. Magn. Reson. Imag."},{"key":"10.1016\/j.mri.2020.10.016_bb0150","first-page":"266","article-title":"Continuously moving table aorto-iliofemoral run-off contrast-enhanced magnetic resonance angiography: image quality analysis in comparison to the multistep acquisition","volume":"55","author":"Asbach","year":"2014","journal-title":"Acta Radiol. (Stockholm, Sweden\u202f: 1987)"},{"key":"10.1016\/j.mri.2020.10.016_bb0155","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.ejrad.2011.01.019","article-title":"Peripheral MRA with continuous table movement: imaging speed and robustness compared to a conventional stepping table technique","volume":"80","author":"Koziel","year":"2011","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.mri.2020.10.016_bb0160","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1148\/radiol.2402050223","article-title":"Peripheral arterial disease: clinical and cost comparisons between duplex US and contrast-enhanced MR angiography--a multicenter randomized trial","volume":"240","author":"de Vries","year":"2006","journal-title":"Radiology."},{"key":"10.1016\/j.mri.2020.10.016_bb0165","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1148\/radiol.10100781","article-title":"Peripheral arterial occlusive disease: evaluation of a high spatial and temporal resolution 3-T MR protocol with a low total dose of gadolinium versus conventional angiography","volume":"257","author":"Attenberger","year":"2010","journal-title":"Radiology."},{"key":"10.1016\/j.mri.2020.10.016_bb0170","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1136\/bmj.39217.473275.55","article-title":"Duplex ultrasonography, magnetic resonance angiography, and computed tomography angiography for diagnosis and assessment of symptomatic, lower limb peripheral arterial disease: systematic review","volume":"334","author":"Collins","year":"2007","journal-title":"BMJ (Clin. Res. ed)"},{"key":"10.1016\/j.mri.2020.10.016_bb0175","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1515\/bmt-2013-0113","article-title":"Non-invasive ECG-triggered 2D TOF MR angiography of the pelvic and leg arteries in an open 1.0-tesla high-field MRI system in comparison to conventional DSA","volume":"59","author":"Suttmeyer","year":"2014","journal-title":"Biomed Tech (Berl)"},{"key":"10.1016\/j.mri.2020.10.016_bb0180","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1007\/s00330-016-4448-6","article-title":"Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques","volume":"27","author":"Altaha","year":"2017","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.mri.2020.10.016_bb0185","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1148\/radiol.2531090290","article-title":"Three-dimensional electrocardiographically gated variable flip angle FSE imaging for MR angiography of the hands at 3.0 T: initial experience","volume":"252","author":"Lim","year":"2009","journal-title":"Radiology"},{"key":"10.1016\/j.mri.2020.10.016_bb0190","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1002\/jmri.22457","article-title":"Nonenhanced methods for lower-extremity MRA: a phantom study examining the effects of stenosis and pathologic flow waveforms at 1.5T","volume":"33","author":"Offerman","year":"2011","journal-title":"J. Magn. Reson. Imag."},{"key":"10.1016\/j.mri.2020.10.016_bb0195","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.jcmg.2016.09.030","article-title":"Accuracy of noncontrast quiescent-interval single-shot lower extremity MR angiography versus CT angiography for diagnosis of peripheral artery disease: comparison with digital subtraction angiography","volume":"10","author":"Varga-Szemes","year":"2017","journal-title":"J. Am. Coll. Cardiol. Img."},{"key":"10.1016\/j.mri.2020.10.016_bb0200","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.jcmg.2016.09.030","article-title":"Accuracy of noncontrast quiescent-interval single-shot lower extremity MR angiography versus CT angiography for diagnosis of peripheral artery disease: comparison with digital subtraction angiography","volume":"10","author":"Varga-Szemes","year":"2017","journal-title":"J. Am. Coll. Cardiol. Img."}],"container-title":["Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0730725X20306299?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0730725X20306299?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T08:36:19Z","timestamp":1759998979000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0730725X20306299"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2]]},"references-count":40,"alternative-id":["S0730725X20306299"],"URL":"https:\/\/doi.org\/10.1016\/j.mri.2020.10.016","relation":{},"ISSN":["0730-725X"],"issn-type":[{"value":"0730-725X","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Non-contrast-enhanced MR-angiography (MRA) of lower extremity peripheral arterial disease at 3\u00a0tesla: Examination time and diagnostic performance of 2D quiescent-interval single-shot MRA vs. 3D fast spin-Echo MRA","name":"articletitle","label":"Article Title"},{"value":"Magnetic Resonance Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.mri.2020.10.016","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}