{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T19:20:03Z","timestamp":1786994403834,"version":"build-2736575974"},"reference-count":59,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2027,2,26]],"date-time":"2027-02-26T00:00:00Z","timestamp":1803600000000},"content-version":"am","delay-in-days":270,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/100000070","name":"National Institute of Biomedical Imaging and Bioengineering","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000070","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1016\/j.mri.2026.110643","type":"journal-article","created":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T16:56:47Z","timestamp":1771952207000},"page":"110643","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Accelerated reconstruction of 5D free-running MRI with variable projection-augmented Lagrangian (VPAL)"],"prefix":"10.1016","volume":"129","author":[{"given":"Yitong","family":"Yang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad","family":"Naeem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marly","family":"van Assen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jerome","family":"Yerly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davide","family":"Piccini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Stuber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Oshinski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Chung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.mri.2026.110643_bb0005","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/S0002-9149(02)02381-0","article-title":"Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy","volume":"90","author":"Grothues","year":"2002","journal-title":"Am J Cardiol"},{"issue":"5","key":"10.1016\/j.mri.2026.110643_bb0010","first-page":"345","article-title":"Quantification of regional myocardial wall motion by cardiovascular magnetic resonance","volume":"4","author":"Jiang","year":"2014","journal-title":"Quant Imaging Med Surg"},{"key":"10.1016\/j.mri.2026.110643_bb0015","series-title":"Nat Med","first-page":"1471","article-title":"Screening and diagnosis of cardiovascular disease using artificial intelligence-enabled cardiac magnetic resonance imaging","volume":"30","author":"Wang","year":"2024"},{"issue":"3","key":"10.1016\/j.mri.2026.110643_bb0020","doi-asserted-by":"crossref","first-page":"753","DOI":"10.3390\/jcm13030753","article-title":"Optimizing clinical cardiac MRI workflow through single breath-hold compressed sensing cine: an evaluation of feasibility and efficiency","volume":"13","author":"Wang","year":"2024","journal-title":"J Clin Med"},{"issue":"1","key":"10.1016\/j.mri.2026.110643_bb0195","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1002\/mrm.29634","article-title":"Focused navigation for respiratory\u2013motion-corrected free-running radial 4D flow MRI","volume":"90","author":"Falc\u00e3o","year":"2023","journal-title":"Magn Reson Med"},{"issue":"7","key":"10.1016\/j.mri.2026.110643_bb0175","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6579\/aa6e8c","article-title":"Acquisition of electrocardiogram signals during magnetic resonance imaging","volume":"38","author":"Oster","year":"2017","journal-title":"Physiol Meas"},{"issue":"1","key":"10.1016\/j.mri.2026.110643_bb0275","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1186\/s12968-020-00611-5","article-title":"3D whole-heart isotropic sub-millimeter resolution coronary magnetic resonance angiography with non-rigid motion-compensated PROST","volume":"22","author":"Bustin","year":"2020","journal-title":"J Cardiovasc Magn Reson"},{"issue":"5","key":"10.1016\/j.mri.2026.110643_bb0180","doi-asserted-by":"crossref","first-page":"1443","DOI":"10.1002\/mrm.26050","article-title":"Coronary endothelial function assessment using self-gated cardiac cine MRI and k-t sparse SENSE","volume":"76","author":"Yerly","year":"2016","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110643_bb0185","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.mri.2016.12.021","article-title":"Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory","volume":"38","author":"Usman","year":"2017","journal-title":"Magn Reson Imaging"},{"issue":"6","key":"10.1016\/j.mri.2026.110643_bb0035","doi-asserted-by":"crossref","first-page":"2118","DOI":"10.1002\/mrm.27898","article-title":"An automated approach to fully self-gated free-running cardiac and respiratory motion-resolved 5D whole-heart MRI","volume":"82","author":"Di Sopra","year":"2019","journal-title":"Magn Reson Med"},{"issue":"2","key":"10.1016\/j.mri.2026.110643_bb0190","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1002\/mrm.23247","article-title":"Respiratory self-navigation for whole-heart bright-blood coronary MRI: methods for robust isolation and automatic segmentation of the blood pool","volume":"68","author":"Piccini","year":"2012","journal-title":"Magn Reson Med"},{"issue":"4","key":"10.1016\/j.mri.2026.110643_bb0025","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1002\/mrm.22898","article-title":"Spiral phyllotaxis: the natural way to construct a 3D radial trajectory in MRI","volume":"66","author":"Piccini","year":"2011","journal-title":"Magn Reson Med"},{"issue":"1","key":"10.1016\/j.mri.2026.110643_bb0030","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1186\/s12968-022-00871-3","article-title":"Free-running cardiac and respiratory motion-resolved 5D whole-heart coronary cardiovascular magnetic resonance angiography in pediatric cardiac patients using ferumoxytol","volume":"24","author":"Roy","year":"2022","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1016\/j.mri.2026.110643_bb0040","doi-asserted-by":"crossref","DOI":"10.1016\/j.mri.2024.07.008","article-title":"Quiescent frame, contrast-enhanced coronary magnetic resonance angiography reconstructed using limited number of physiologic frames from 5D free-running acquisitions","volume":"113","author":"Yang","year":"2024","journal-title":"Magn Reson Imaging"},{"issue":"17","key":"10.1016\/j.mri.2026.110643_bb0045","article-title":"Free-running cardiac and respiratory motion-resolved imaging: a paradigm shift for managing motion in cardiac MRI?","volume":"14","author":"Holtackers","year":"2024","journal-title":"Diagnostics (Basel)"},{"issue":"2","key":"10.1016\/j.mri.2026.110643_bb0050","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1002\/mrm.26745","article-title":"5D whole-heart sparse MRI","volume":"79","author":"Feng","year":"2018","journal-title":"Magn Reson Med"},{"issue":"2","key":"10.1016\/j.mri.2026.110643_bb0055","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1002\/mrm.25665","article-title":"XD-GRASP: golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing","volume":"75","author":"Feng","year":"2016","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110643_bb0060","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","article-title":"SENSE: sensitivity encoding for fast MRI","volume":"42","author":"Pruessmann","year":"1999","journal-title":"Magn Reson Med"},{"issue":"6","key":"10.1016\/j.mri.2026.110643_bb0065","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1002\/mrm.21391","article-title":"Sparse MRI: the application of compressed sensing for rapid MR imaging","volume":"58","author":"Lustig","year":"2007","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110643_bb0070","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1109\/TSP.2002.807005","article-title":"Nonuniform fast Fourier transforms using min-max interpolation","volume":"51","author":"Fessler","year":"2003","journal-title":"IEEE Trans Signal Process"},{"key":"10.1016\/j.mri.2026.110643_bb0075","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1109\/TMI.2005.848376","article-title":"Rapid gridding reconstruction with a minimal oversampling ratio","volume":"24","author":"Beatty","year":"2005","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.mri.2026.110643_bb0080","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1002\/mrm.21691","article-title":"Image reconstruction by regularized nonlinear inversion\u2014joint estimation of coil sensitivities and image content","volume":"60","author":"Uecker","year":"2008","journal-title":"Magn Reson Med"},{"issue":"4","key":"10.1016\/j.mri.2026.110643_bb0085","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1109\/MSP.2010.936726","article-title":"Model-based image reconstruction for MRI","volume":"27","author":"Fessler","year":"2010","journal-title":"IEEE Signal Process Mag"},{"issue":"6","key":"10.1016\/j.mri.2026.110643_bb0090","doi-asserted-by":"crossref","first-page":"1086","DOI":"10.1002\/mrm.21236","article-title":"Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint","volume":"57","author":"Block","year":"2007","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110643_bb0095","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/0167-2789(92)90242-F","article-title":"Nonlinear total variation noise removal algorithm","volume":"60","author":"Rudin","year":"1992","journal-title":"Phys D"},{"key":"10.1016\/j.mri.2026.110643_bb0100","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1002\/mrm.25240","article-title":"Low-rank plus sparse (L+S) decomposition for accelerated dynamic MRI","volume":"73","author":"Otazo","year":"2015","journal-title":"Magn Reson Med"},{"issue":"3","key":"10.1016\/j.mri.2026.110643_bb0105","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1002\/mrm.25240","article-title":"Low-rank plus sparse matrix decomposition for accelerated dynamic MRI with separation of background and dynamic components","volume":"73","author":"Otazo","year":"2015","journal-title":"Magn Reson Med"},{"issue":"2","key":"10.1016\/j.mri.2026.110643_bb0110","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1109\/TMI.2002.808360","article-title":"Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities","volume":"22","author":"Sutton","year":"2003","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.mri.2026.110643_bb0115","doi-asserted-by":"crossref","first-page":"1334","DOI":"10.1007\/s10851-020-00985-2","article-title":"Temporal Huber regularization for DCE-MRI","volume":"62","author":"Hanhela","year":"2020","journal-title":"J Math Imaging Vis"},{"issue":"4","key":"10.1016\/j.mri.2026.110643_bb0200","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1137\/090757617","article-title":"Global solutions of variational models with convex regularization","volume":"3","author":"Pock","year":"2010","journal-title":"SIAM J Imaging Sci"},{"issue":"9","key":"10.1016\/j.mri.2026.110643_bb0205","doi-asserted-by":"crossref","first-page":"1334","DOI":"10.1007\/s10851-020-00985-2","article-title":"Temporal Huber regularization for DCE-MRI","volume":"62","author":"Hanhela","year":"2020","journal-title":"J Math Imaging Vis"},{"key":"10.1016\/j.mri.2026.110643_bb0210","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6420\/aac3af","article-title":"Dynamic MRI reconstruction from undersampled data with an anatomical prescan","volume":"34","author":"Rasch","year":"2018","journal-title":"Inverse Probl"},{"key":"10.1016\/j.mri.2026.110643_bb0215","first-page":"11","article-title":"Quantitative Evaluation of Temporal Regularizers in Compressed Sensing Dynamic Contrast Enhanced MRI of the Breast","volume":"7835749","author":"Wang","year":"2017","journal-title":"Int J Biomed Imaging"},{"key":"10.1016\/j.mri.2026.110643_bb0220","first-page":"109","article-title":"Spatio-temporal constrained re-construction of sparse dynamic contrast enhanced radial MRI data","author":"Adluru","year":"2007","journal-title":"Proc IEEE Int Symp Biomed Imaging"},{"issue":"3","key":"10.1016\/j.mri.2026.110643_bb0120","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1109\/TMI.2010.2093536","article-title":"Parallel MR image reconstruction using augmented Lagrangian methods","volume":"30","author":"Ramani","year":"2011","journal-title":"IEEE Trans Med Imaging"},{"issue":"2","key":"10.1016\/j.mri.2026.110643_bb0125","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1137\/080725891","article-title":"The split Bregman method for L1-regularized problems","volume":"2","author":"Goldstein","year":"2009","journal-title":"SIAM J Imaging Sci"},{"key":"10.1016\/j.mri.2026.110643_bb0130","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1137\/0710036","article-title":"The differentiation of pseudoinverses and nonlinear least squares problems whose variables separate","volume":"10","author":"Golub","year":"1973","journal-title":"SIAM J Numer Anal"},{"issue":"2","key":"10.1016\/j.mri.2026.110643_bb0135","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0266-5611\/19\/2\/201","article-title":"Separable nonlinear least squares: the variable projection method and its applications","volume":"19","author":"Golub","year":"2003","journal-title":"Inverse Probl"},{"issue":"3","key":"10.1016\/j.mri.2026.110643_bb0140","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1002\/mrm.21522","article-title":"Joint estimation of water\/fat images and field inhomogeneity map","volume":"59","author":"Hernando","year":"2008","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110643_bb0145","first-page":"41","article-title":"Maximum likelihood estimation of T1 relaxation parameters using VARPRO","author":"Haldar","year":"2007","journal-title":"ISMRM"},{"key":"10.1016\/j.mri.2026.110643_bb0150","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/j.apnum.2023.06.015","article-title":"A variable projection method for large-scale inverse problems with \u21131 regularization","volume":"192","author":"Chung","year":"2023","journal-title":"Appl Numer Math"},{"issue":"6","key":"10.1016\/j.mri.2026.110643_bib292","doi-asserted-by":"crossref","first-page":"065014","DOI":"10.1088\/1361-6420\/addde4","article-title":"Renaut Rosemary Anne, Chung Matthias Fast \u21131-regularized EEG source localization using variable projection","volume":"41","author":"Solomon Jack","year":"2025","journal-title":"Inverse Probl"},{"issue":"9","key":"10.1016\/j.mri.2026.110643_bb0280","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","article-title":"3D slicer as an image computing platform for the quantitative imaging network","volume":"30","author":"Fedorov","year":"2012","journal-title":"Magn Reson Imaging"},{"key":"10.1016\/j.mri.2026.110643_bb0170","doi-asserted-by":"crossref","DOI":"10.3389\/fradi.2023.1144004","article-title":"Deep learning-based left ventricular segmentation demonstrates improved performance on respiratory motion-resolved whole-heart reconstructions","volume":"3","author":"Yang","year":"2023","journal-title":"Front Radiol"},{"issue":"7","key":"10.1016\/j.mri.2026.110643_bb0155","doi-asserted-by":"crossref","first-page":"3142","DOI":"10.1109\/TIP.2017.2662206","article-title":"Beyond a Gaussian denoiser: residual learning of deep CNN for image denoising","volume":"26","author":"Zhang","year":"2017","journal-title":"IEEE Trans Image Process"},{"key":"10.1016\/j.mri.2026.110643_bb0160","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1007\/s11600-021-00569-7","article-title":"Machine-learning-based prediction of regularization parameters for seismic inverse problems","volume":"69","author":"Liu","year":"2021","journal-title":"Acta Geophys"},{"issue":"3","key":"10.1016\/j.mri.2026.110643_bb0165","doi-asserted-by":"crossref","first-page":"S196","DOI":"10.1016\/j.ijrobp.2018.07.092","article-title":"Parameter tuning in regularization-based iterative CT reconstruction via deep reinforcement learning","volume":"102","author":"Shen","year":"2018","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"13","key":"10.1016\/j.mri.2026.110643_bb0225","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/aac71a","article-title":"Deep learning for undersampled MRI reconstruction","volume":"63","author":"Hyun","year":"2018","journal-title":"Phys Med Biol"},{"issue":"1","key":"10.1016\/j.mri.2026.110643_bb0230","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-025-23851-w","article-title":"Magnetic resonance image processing transformer for general accelerated image restoration","volume":"15","author":"Shen","year":"2025","journal-title":"Sci Rep"},{"key":"10.1016\/j.mri.2026.110643_bb0235","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/j.neucom.2022.04.051","article-title":"Swin transformer for fast MRI","volume":"493","author":"Huang","year":"2022","journal-title":"Neurocomputing"},{"issue":"6","key":"10.1016\/j.mri.2026.110643_bb0240","doi-asserted-by":"crossref","first-page":"3055","DOI":"10.1002\/mrm.26977","article-title":"Learning a variational network for reconstruction of accelerated MRI data","volume":"79","author":"Hammernik","year":"2018","journal-title":"Magn Reson Med"},{"issue":"2","key":"10.1016\/j.mri.2026.110643_bb0245","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1109\/TMI.2018.2865356","article-title":"MoDL: model-based deep learning architecture for inverse problems","volume":"38","author":"Aggarwal","year":"2018","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.mri.2026.110643_bb0250","doi-asserted-by":"crossref","DOI":"10.1016\/j.mri.2024.110244","article-title":"Deep plug-and-play MRI reconstruction based on multiple complementary priors","volume":"115","author":"Wang","year":"2025","journal-title":"Magn Reson Imaging"},{"issue":"1","key":"10.1016\/j.mri.2026.110643_bb0255","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1109\/MSP.2019.2949470","article-title":"Plug-and-play methods for magnetic resonance imaging: using denoisers for image recovery","volume":"37","author":"Ahmad","year":"2020","journal-title":"IEEE Signal Process Mag"},{"key":"10.1016\/j.mri.2026.110643_bb0260","series-title":"International Conference on Medical Image Computing and Computer-Assisted Intervention","first-page":"484","article-title":"Multi-GPU reconstruction of dynamic compressed sensing MRI","author":"Quan","year":"2015"},{"key":"10.1016\/j.mri.2026.110643_bb0265","series-title":"Proceedings of the 5th Conference on Computing Frontiers","first-page":"261","article-title":"Accelerating advanced MRI reconstructions on GPUs","author":"Stone","year":"2008"},{"key":"10.1016\/j.mri.2026.110643_bb0270","series-title":"2020 IEEE High Performance Extreme Computing Conference (HPEC)","first-page":"1","article-title":"Accelerating mri reconstruction on tpus","author":"Lu","year":"2020"},{"key":"10.1016\/j.mri.2026.110643_bb0285","article-title":"Deep ADMM-net for compressive sensing MRI","volume":"29","author":"Sun","year":"2016","journal-title":"Adv Neural Inf Process Syst"},{"key":"10.1016\/j.mri.2026.110643_bb0290","series-title":"2013 IEEE Global Conference on Signal and Information Processing","first-page":"945","article-title":"Plug-and-play priors for model based reconstruction","author":"Venkatakrishnan","year":"2013"}],"container-title":["Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0730725X26000366?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0730725X26000366?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T18:06:23Z","timestamp":1777572383000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0730725X26000366"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":59,"alternative-id":["S0730725X26000366"],"URL":"https:\/\/doi.org\/10.1016\/j.mri.2026.110643","relation":{},"ISSN":["0730-725X"],"issn-type":[{"value":"0730-725X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accelerated reconstruction of 5D free-running MRI with variable projection-augmented Lagrangian (VPAL)","name":"articletitle","label":"Article Title"},{"value":"Magnetic Resonance Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.mri.2026.110643","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"110643"}}