{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T18:07:27Z","timestamp":1788890847709,"version":"build-2803163510"},"reference-count":27,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2027,1]]},"DOI":"10.1016\/j.mri.2026.110787","type":"journal-article","created":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T23:05:18Z","timestamp":1788390318000},"page":"110787","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Acceleration-dependent variability in simultaneous T1\/T2 mapping with a hybrid (mixed) sequence: a phantom comparison of SENSE, compressed sensing, and deep learning reconstructions"],"prefix":"10.1016","volume":"135","author":[{"given":"Masayuki","family":"Kanamoto","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuki","family":"Matta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiki","family":"Tateishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Tsushima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuya","family":"Tsujikawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.mri.2026.110787_bb0005","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1002\/mrm.20110","article-title":"Modified look-locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart","volume":"52","author":"Messroghli","year":"2004","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0010","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1148\/radiol.211519","article-title":"Primary multiparametric quantitative brain MRI: state-of-the-art relaxometric and proton density mapping techniques","volume":"305","author":"Jara","year":"2022","journal-title":"Radiology"},{"key":"10.1016\/j.mri.2026.110787_bb0015","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1097\/RLI.0b013e318200f67d","article-title":"Estimation of liver function using T1 mapping on Gd-EOB-DTPA-enhanced magnetic resonance imaging","volume":"46","author":"Katsube","year":"2011","journal-title":"Invest Radiol"},{"key":"10.1016\/j.mri.2026.110787_bb0020","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1002\/mrm.1910050602","article-title":"RLSQ: T1, T2, and rho calculations, combining ratios and least squares","volume":"5","author":"In den Kleef","year":"1987","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0025","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1002\/mrm.21165","article-title":"Novel method for rapid, simultaneous T1, T2*, and proton density quantification","volume":"57","author":"Warntjes","year":"2007","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0030","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1002\/mrm.21635","article-title":"Rapid magnetic resonance quantification on the brain: optimization for clinical usage","volume":"60","author":"Warntjes","year":"2008","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0035","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","article-title":"SENSE: sensitivity encoding for fast MRI","volume":"42","author":"Pruessmann","year":"1999","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0040","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1002\/mrm.10171","article-title":"Generalized autocalibrating partially parallel acquisitions (GRAPPA)","volume":"47","author":"Griswold","year":"2002","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0045","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1002\/mrm.21391","article-title":"Sparse MRI: the application of compressed sensing for rapid MR imaging","volume":"58","author":"Lustig","year":"2007","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0050","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1002\/mrm.24751","article-title":"ESPIRiT\u2014an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA","volume":"71","author":"Uecker","year":"2014","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0055","doi-asserted-by":"crossref","first-page":"3055","DOI":"10.1002\/mrm.26977","article-title":"Learning a variational network for reconstruction of accelerated MRI data","volume":"79","author":"Hammernik","year":"2018","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0060","doi-asserted-by":"crossref","first-page":"17","DOI":"10.3389\/fcvm.2020.00017","article-title":"From compressed-sensing to artificial intelligence-based cardiac MRI reconstruction","volume":"7","author":"Bustin","year":"2020","journal-title":"Front Cardiovasc Med"},{"key":"10.1016\/j.mri.2026.110787_bb0065","doi-asserted-by":"crossref","first-page":"3211","DOI":"10.1002\/mrm.28659","article-title":"Magnetic resonance parameter mapping using model-guided self-supervised deep learning","volume":"85","author":"Liu","year":"2021","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0070","doi-asserted-by":"crossref","DOI":"10.1016\/j.media.2021.102017","article-title":"Deep model-based magnetic resonance parameter mapping network (DOPAMINE) for fast T1 mapping using variable flip angle method","volume":"70","author":"Jun","year":"2021","journal-title":"Med Image Anal"},{"key":"10.1016\/j.mri.2026.110787_bb0075","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.1002\/mrm.28793","article-title":"Deep learning-enhanced T1 mapping with spatial-temporal and physical constraint","volume":"86","author":"Li","year":"2021","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0080","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1002\/mrm.28526","article-title":"Accelerating T2 mapping of the brain by integrating deep learning priors with low-rank and sparse modeling","volume":"85","author":"Meng","year":"2021","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0085","doi-asserted-by":"crossref","first-page":"2127","DOI":"10.1002\/mrm.28568","article-title":"Deep learning reconstruction for cardiac magnetic resonance fingerprinting T1 and T2 mapping","volume":"85","author":"Hamilton","year":"2021","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0090","doi-asserted-by":"crossref","first-page":"2294","DOI":"10.1002\/mrm.29989","article-title":"Joint MAPLE: accelerated joint T1 and T2\u204e mapping with scan-specific self-supervised networks","volume":"91","author":"Heydari","year":"2024","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0095","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1002\/mrm.30045","article-title":"Improving quantitative MRI using self-supervised deep learning with model reinforcement: demonstration for rapid T1 mapping","volume":"92","author":"Bian","year":"2024","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0100","first-page":"2683","article-title":"Physics-guided self-supervised learning for retrospective T1 and T2 mapping from conventional weighted brain MRI: technical developments and initial validation in glioblastoma","volume":"92","author":"Qiu","year":"2024","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mri.2026.110787_bb0105","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1109\/TIP.2003.819861","article-title":"Image quality assessment: from error visibility to structural similarity","volume":"13","author":"Wang","year":"2004","journal-title":"IEEE Trans Image Process"},{"key":"10.1016\/j.mri.2026.110787_bb0110","doi-asserted-by":"crossref","DOI":"10.1118\/1.4790023","article-title":"Development of MRI phantom equivalent to human tissues for 3.0\u2212TMRI","volume":"40","author":"Hattori","year":"2013","journal-title":"Med Phys"},{"key":"10.1016\/j.mri.2026.110787_bb0115","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1097\/RLI.0000000000000365","article-title":"SyMRI of the brain: rapid quantification of relaxation rates and proton density, with synthetic MRI, automatic brain segmentation, and myelin measurement","volume":"52","author":"Hagiwara","year":"2017","journal-title":"Invest Radiol"},{"key":"10.1016\/j.mri.2026.110787_bb0130","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1038\/nature11971","article-title":"Magnetic resonance fingerprinting","volume":"495","author":"Ma","year":"2013","journal-title":"Nature"},{"key":"10.1016\/j.mri.2026.110787_bb0120","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1002\/mrm.27198","article-title":"MR fingerprinting Deep RecOnstruction NEtwork (DRONE)","volume":"80","author":"Cohen","year":"2018","journal-title":"Magn Reson Med"},{"issue":"4","key":"10.1016\/j.mri.2026.110787_bb0135","doi-asserted-by":"crossref","DOI":"10.2463\/mrms.mp.2024-0025","article-title":"High resolution TOF-MRA using compressed sensing-based deep learning image reconstruction for the visualization of lenticulostriate arteries: a preliminary study","volume":"24","author":"Hirano","year":"2025","journal-title":"Magn Reson Med Sci"},{"key":"10.1016\/j.mri.2026.110787_bb0140","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.mri.2021.06.014","article-title":"Single-breath-hold T2WI liver MRI with deep learning-based reconstruction: a clinical feasibility study in comparison to conventional multi-breath-hold T2WI liver MRI","volume":"81","author":"Sheng","year":"2021","journal-title":"Magn Reson Imaging"}],"container-title":["Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0730725X26001803?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0730725X26001803?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T17:17:07Z","timestamp":1788887827000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0730725X26001803"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2027,1]]},"references-count":27,"alternative-id":["S0730725X26001803"],"URL":"https:\/\/doi.org\/10.1016\/j.mri.2026.110787","relation":{},"ISSN":["0730-725X"],"issn-type":[{"value":"0730-725X","type":"print"}],"subject":[],"published":{"date-parts":[[2027,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Acceleration-dependent variability in simultaneous T1\/T2 mapping with a hybrid (mixed) sequence: a phantom comparison of SENSE, compressed sensing, and deep learning reconstructions","name":"articletitle","label":"Article Title"},{"value":"Magnetic Resonance Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.mri.2026.110787","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"110787"}}