{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T10:23:48Z","timestamp":1783592628462,"version":"3.55.0"},"reference-count":53,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2020,8,1]],"date-time":"2020-08-01T00:00:00Z","timestamp":1596240000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,8,1]],"date-time":"2020-08-01T00:00:00Z","timestamp":1596240000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","theclinics.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging Clinics of North America"],"published-print":{"date-parts":[[2020,8]]},"DOI":"10.1016\/j.mric.2020.03.005","type":"journal-article","created":{"date-parts":[[2020,6,3]],"date-time":"2020-06-03T07:42:16Z","timestamp":1591170136000},"page":"395-405","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Abdominal Magnetic Resonance Angiography"],"prefix":"10.1016","volume":"28","author":[{"given":"Christopher J.","family":"Fran\u00e7ois","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.mric.2020.03.005_bib1","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1002\/mrm.10171","article-title":"Generalized autocalibrating partially parallel acquisitions (GRAPPA)","volume":"47","author":"Griswold","year":"2002","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mric.2020.03.005_bib2","doi-asserted-by":"crossref","first-page":"1629","DOI":"10.1118\/1.1386778","article-title":"A\u00a0generalized approach to parallel magnetic resonance imaging","volume":"28","author":"Sodickson","year":"2001","journal-title":"Med Phys"},{"key":"10.1016\/j.mric.2020.03.005_bib3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1081\/JCMR-100000143","article-title":"Sensitivity encoded cardiac MRI","volume":"3","author":"Pruessmann","year":"2001","journal-title":"J\u00a0Cardiovasc Magn Reson"},{"key":"10.1016\/j.mric.2020.03.005_bib4","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1097\/01.rmr.0000134199.94874.70","article-title":"Parallel imaging in MR angiography","volume":"15","author":"Wilson","year":"2004","journal-title":"Top Magn Reson Imaging"},{"key":"10.1016\/j.mric.2020.03.005_bib5","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1002\/jmri.21964","article-title":"Increased volume of coverage for abdominal contrast-enhanced MR angiography with two-dimensional autocalibrating parallel imaging: initial experience at 3.0 Tesla","volume":"30","author":"Lum","year":"2009","journal-title":"J\u00a0Magn Reson Imaging"},{"key":"10.1016\/j.mric.2020.03.005_bib6","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1148\/radiol.2501080494","article-title":"Ultrafast whole-body MR angiography with two-dimensional parallel imaging at 3.0 T: feasibility study","volume":"250","author":"Fenchel","year":"2009","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib7","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.mric.2008.12.005","article-title":"Neurovascular imaging at 1.5 tesla versus 3.0 tesla","volume":"17","author":"Huang","year":"2009","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"10.1016\/j.mric.2020.03.005_bib8","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1148\/radiol.2493080209","article-title":"Supraaortic arteries: contrast material dose reduction at 3.0-T high-spatial-resolution MR angiography--feasibility study","volume":"249","author":"Tomasian","year":"2008","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib9","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1148\/radiol.2482071505","article-title":"High-spatial-resolution lower extremity MR angiography at 3.0 T: contrast agent dose comparison study","volume":"248","author":"Habibi","year":"2008","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib10","doi-asserted-by":"crossref","first-page":"1260","DOI":"10.1007\/s00330-008-0873-5","article-title":"Three-dimensional contrast-enhanced magnetic-resonance angiography of the renal arteries: interindividual comparison of 0.2 mmol\/kg gadobutrol at 1.5 T and 0.1 mmol\/kg gadobenate\u00a0dimeglumine at 3.0 T","volume":"18","author":"Attenberger","year":"2008","journal-title":"Eur Radiol"},{"key":"10.1016\/j.mric.2020.03.005_bib11","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1097\/01.rli.0000261937.77365.6a","article-title":"3.0 Tesla high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the pulmonary circulation: initial experience with a 32-channel phased array coil using a high relaxivity contrast agent","volume":"42","author":"Nael","year":"2007","journal-title":"Invest Radiol"},{"key":"10.1016\/j.mric.2020.03.005_bib12","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1148\/radiol.2471070565","article-title":"Isotropic high-spatial-resolution contrast-enhanced 3.0-T MR angiography in patients suspected of having renal artery stenosis","volume":"247","author":"Kramer","year":"2008","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib13","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1148\/rg.275065204","article-title":"Body MR imaging at 3.0 T: understanding the opportunities and challenges","volume":"27","author":"Barth","year":"2007","journal-title":"Radiographics"},{"key":"10.1016\/j.mric.2020.03.005_bib14","doi-asserted-by":"crossref","first-page":"896","DOI":"10.1148\/radiol.2243010984","article-title":"Thorax: low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution--initial results","volume":"224","author":"Finn","year":"2002","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib15","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1002\/jmri.1880030419","article-title":"\"Keyhole\" method for accelerating imaging of contrast agent uptake","volume":"3","author":"van Vaals","year":"1993","journal-title":"J\u00a0Magn Reson Imaging"},{"key":"10.1016\/j.mric.2020.03.005_bib16","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1002\/mrm.1910360304","article-title":"Time-resolved contrast-enhanced 3D MR angiography","volume":"36","author":"Korosec","year":"1996","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mric.2020.03.005_bib17","doi-asserted-by":"crossref","first-page":"1847","DOI":"10.3174\/ajnr.A1252","article-title":"3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA","volume":"29","author":"Lim","year":"2008","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.mric.2020.03.005_bib18","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1002\/mrm.21675","article-title":"3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain","volume":"60","author":"Haider","year":"2008","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mric.2020.03.005_bib19","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1148\/radiology.201.3.8939219","article-title":"Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector","volume":"201","author":"Earls","year":"1996","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib20","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1148\/radiology.205.1.9314975","article-title":"Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: application to the renal arteries","volume":"205","author":"Wilman","year":"1997","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib21","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1002\/jmri.1880060413","article-title":"The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality","volume":"6","author":"Maki","year":"1996","journal-title":"J\u00a0Magn Reson Imaging"},{"key":"10.1016\/j.mric.2020.03.005_bib22","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.2214\/AJR.08.1688","article-title":"Comparison of test performance characteristics of MRI, MR angiography, and CT angiography in the diagnosis of carotid and vertebral artery dissection: a review of the medical literature","volume":"193","author":"Provenzale","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.mric.2020.03.005_bib23","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1007\/s00330-008-1171-y","article-title":"Evaluation of angiographic computed tomography in the follow-up after endovascular treatment of cerebral aneurysms--a comparative study with DSA and TOF-MRA","volume":"19","author":"Buhk","year":"2009","journal-title":"Eur Radiol"},{"key":"10.1016\/j.mric.2020.03.005_bib24","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1148\/radiol.2481071497","article-title":"Nonenhanced MR angiography","volume":"248","author":"Miyazaki","year":"2008","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib25","doi-asserted-by":"crossref","first-page":"902","DOI":"10.2214\/AJR.07.2997","article-title":"Unenhanced MR angiography of the thoracic aorta: initial clinical evaluation","volume":"190","author":"Francois","year":"2008","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.mric.2020.03.005_bib26","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1148\/radiol.2502072137","article-title":"Pulmonary vein imaging with unenhanced three-dimensional balanced steady-state free precession MR angiography: initial clinical evaluation","volume":"250","author":"Francois","year":"2009","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib27","doi-asserted-by":"crossref","first-page":"1311","DOI":"10.1007\/s00330-009-1672-3","article-title":"Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases","volume":"20","author":"Krishnam","year":"2010","journal-title":"Eur Radiol"},{"key":"10.1016\/j.mric.2020.03.005_bib28","doi-asserted-by":"crossref","first-page":"36","DOI":"10.4103\/0974-2069.79621","article-title":"Comparison of contrast and noncontrast magnetic resonance angiography for quantitative analysis of thoracic arteries in young patients with congenital heart defects","volume":"4","author":"Pasqua","year":"2011","journal-title":"Ann Pediatr Cardiol"},{"key":"10.1016\/j.mric.2020.03.005_bib29","doi-asserted-by":"crossref","first-page":"966","DOI":"10.1002\/jmri.21134","article-title":"Steady-state free precession MRA of the renal arteries: breath-hold and navigator-gated techniques vs. CE-MRA","volume":"26","author":"Maki","year":"2007","journal-title":"J\u00a0Magn Reson Imaging"},{"key":"10.1016\/j.mric.2020.03.005_bib30","doi-asserted-by":"crossref","first-page":"W540","DOI":"10.2214\/AJR.06.1138","article-title":"Navigator-gated MR angiography of the renal arteries: a potential screening tool for renal artery stenosis","volume":"188","author":"Maki","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.mric.2020.03.005_bib31","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1148\/radiol.2443061769","article-title":"Renal artery assessment with nonenhanced steady-state free precession versus contrast-enhanced MR angiography","volume":"245","author":"Wyttenbach","year":"2007","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib32","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.1002\/jmri.22194","article-title":"Non-contrast renal artery MRA using an inflow inversion recovery steady state free precession technique (Inhance): comparison with 3D contrast-enhanced MRA","volume":"31","author":"Glockner","year":"2010","journal-title":"J\u00a0Magn Reson Imaging"},{"key":"10.1016\/j.mric.2020.03.005_bib33","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1002\/mrm.1910040214","article-title":"MR angiography by selective inversion recovery","volume":"4","author":"Nishimura","year":"1987","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.mric.2020.03.005_bib34","first-page":"229","article-title":"Phase contrast cine magnetic resonance imaging","volume":"7","author":"Pelc","year":"1991","journal-title":"Magn Reson Q"},{"key":"10.1016\/j.mric.2020.03.005_bib35","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1081\/JCMR-200065639","article-title":"How we perform cardiovascular magnetic resonance flow assessment using phase-contrast velocity mapping","volume":"7","author":"Chai","year":"2005","journal-title":"J\u00a0Cardiovasc Magn Reson"},{"key":"10.1016\/j.mric.2020.03.005_bib36","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1148\/radiology.201.3.8939218","article-title":"Renal artery stenosis: value of screening with three-dimensional phase-contrast MR angiography with a phased-array multicoil","volume":"201","author":"De Cobelli","year":"1996","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib37","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1148\/radiology.203.1.9122415","article-title":"Renal artery stenosis: grading of hemodynamic changes with cine phase-contrast MR blood flow measurements","volume":"203","author":"Schoenberg","year":"1997","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib38","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1002\/jmri.23632","article-title":"4D flow MRI","volume":"36","author":"Markl","year":"2012","journal-title":"J\u00a0Magn Reson Imaging"},{"key":"10.1016\/j.mric.2020.03.005_bib39","first-page":"743","article-title":"VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography","volume":"26","author":"Gu","year":"2005","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.mric.2020.03.005_bib40","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1002\/jmri.20871","article-title":"Time-resolved 3D MR velocity mapping at 3T: improved navigator-gated assessment of vascular anatomy and blood flow","volume":"25","author":"Markl","year":"2007","journal-title":"J\u00a0Magn Reson Imaging"},{"key":"10.1016\/j.mric.2020.03.005_bib41","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1148\/radiol.10100443","article-title":"Renal arteries: isotropic, high-spatial-resolution, unenhanced MR angiography with three-dimensional radial phase contrast","volume":"258","author":"Francois","year":"2011","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib42","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1002\/jmri.1880070126","article-title":"Gadolinium-enhanced MR angiography of visceral arteries in patients with suspected chronic mesenteric ischemia","volume":"7","author":"Meaney","year":"1997","journal-title":"J\u00a0Magn Reson Imaging"},{"key":"10.1016\/j.mric.2020.03.005_bib43","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1148\/radiology.194.3.7862982","article-title":"MR measurements of mesenteric venous flow: prospective evaluation in healthy volunteers and patients with suspected chronic mesenteric ischemia","volume":"194","author":"Burkart","year":"1995","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib44","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1148\/radiology.194.2.7824706","article-title":"Simultaneous measurement of flow in the superior mesenteric vein and artery with cine phase-contrast MR imaging: value in diagnosis of chronic mesenteric ischemia. Work in progress","volume":"194","author":"Li","year":"1995","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib45","doi-asserted-by":"crossref","first-page":"401","DOI":"10.7326\/0003-4819-135-6-200109180-00009","article-title":"Diagnostic tests for renal artery stenosis in patients suspected of having renovascular hypertension: a meta-analysis","volume":"135","author":"Vasbinder","year":"2001","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.mric.2020.03.005_bib46","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1148\/radiology.218.2.r01fe36481","article-title":"High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: a prospective comparison with digital subtraction angiography","volume":"218","author":"Fain","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib47","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1148\/radiol.2383050058","article-title":"Renal arteries: comparison of steady-state free precession MR angiography and contrast-enhanced MR angiography","volume":"239","author":"Herborn","year":"2006","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib48","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1023\/A:1006329032742","article-title":"Stenosis quantification from post-stenotic signal loss in phase-contrast MRA datasets of flow phantoms and renal arteries","volume":"15","author":"Westenberg","year":"1999","journal-title":"Int J Card Imaging"},{"key":"10.1016\/j.mric.2020.03.005_bib49","first-page":"H2477","article-title":"Noninvasive analysis of renal artery blood flow dynamics with MR cine phase-contrast flow measurements","volume":"272","author":"Schoenberg","year":"1997","journal-title":"Am J Physiol"},{"key":"10.1016\/j.mric.2020.03.005_bib50","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1148\/radiol.11101175","article-title":"Noninvasive assessment of transstenotic pressure gradients in porcine renal artery stenoses by using vastly undersampled phase-contrast MR angiography","volume":"261","author":"Bley","year":"2011","journal-title":"Radiology"},{"key":"10.1016\/j.mric.2020.03.005_bib51","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1007\/s00270-007-9160-0","article-title":"Chronic pelvic pain due to pelvic congestion syndrome: the role of diagnostic and interventional radiology","volume":"30","author":"Ganeshan","year":"2007","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.mric.2020.03.005_bib52","doi-asserted-by":"crossref","first-page":"e203","DOI":"10.1542\/peds.2014-3673","article-title":"Vascular anomalies classification: recommendations from the international society for the study of vascular anomalies","volume":"136","author":"Wassef","year":"2015","journal-title":"Pediatrics"},{"key":"10.1016\/j.mric.2020.03.005_bib53","doi-asserted-by":"crossref","first-page":"1494","DOI":"10.1148\/rg.2016150197","article-title":"2014 Revised classification of vascular lesions from the international society for the study of vascular anomalies: radiologic-pathologic update","volume":"36","author":"Merrow","year":"2016","journal-title":"Radiographics"}],"container-title":["Magnetic Resonance Imaging Clinics of North America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1064968920300180?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1064968920300180?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T04:37:26Z","timestamp":1761021446000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1064968920300180"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8]]},"references-count":53,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,8]]}},"alternative-id":["S1064968920300180"],"URL":"https:\/\/doi.org\/10.1016\/j.mric.2020.03.005","relation":{},"ISSN":["1064-9689"],"issn-type":[{"value":"1064-9689","type":"print"}],"subject":[],"published":{"date-parts":[[2020,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Abdominal Magnetic Resonance Angiography","name":"articletitle","label":"Article Title"},{"value":"Magnetic Resonance Imaging Clinics of North America","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.mric.2020.03.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}