{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T01:41:56Z","timestamp":1787794916779,"version":"build-2784847793"},"reference-count":161,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2019,7,1]],"date-time":"2019-07-01T00:00:00Z","timestamp":1561939200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,7,1]],"date-time":"2019-07-01T00:00:00Z","timestamp":1561939200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Materials Science and Engineering: C"],"published-print":{"date-parts":[[2019,7]]},"DOI":"10.1016\/j.msec.2019.02.082","type":"journal-article","created":{"date-parts":[[2019,2,22]],"date-time":"2019-02-22T18:33:14Z","timestamp":1550860394000},"page":"70-81","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":94,"special_numbering":"C","title":["Total knee arthroplasty application of polyetheretherketone and carbon-fiber-reinforced polyetheretherketone: A review"],"prefix":"10.1016","volume":"100","author":[{"given":"Yong-Gon","family":"Koh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyoung-Mi","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin-Ah","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji-Hoon","family":"Nam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hwa-Yong","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyoung-Tak","family":"Kang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"5","key":"10.1016\/j.msec.2019.02.082_bb0005","doi-asserted-by":"crossref","first-page":"963","DOI":"10.2106\/00004623-200405000-00012","article-title":"Health-related quality of life in total hip and total knee arthroplasty: a qualitative and systematic review of the literature","volume":"86","author":"Ethgen","year":"2004","journal-title":"J. Bone Joint Surg. Am."},{"issue":"8","key":"10.1016\/j.msec.2019.02.082_bb0010","first-page":"1719","article-title":"The functional outcomes of total knee arthroplasty","volume":"87","author":"Kane","year":"2005","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.msec.2019.02.082_bb0015","series-title":"Global Market","article-title":"Orthopedic devices [Hip, Knee, Other joint reconstruction] market, Global, 2007-2021, USD constant millions","year":"2007"},{"key":"10.1016\/j.msec.2019.02.082_bb0020","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/01.blo.0000229356.81749.11","article-title":"The Chitranjan Ranawat Award: long-term survivorship and failure modes of 1000 cemented condylar total knee arthroplasties","volume":"452","author":"Vessely","year":"2006","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0025","doi-asserted-by":"crossref","first-page":"89","DOI":"10.2106\/JBJS.E.00492","article-title":"Press-fit condylar design total knee arthroplasty. Fourteen to seventeen-year follow-up","volume":"89","author":"Rodricks","year":"2007","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.msec.2019.02.082_bb0030","series-title":"The Clinical Performance of UHMWPE in Knee Replacements","author":"Kurtz","year":"2009"},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0035","doi-asserted-by":"crossref","first-page":"313","DOI":"10.5124\/jkma.2011.54.3.313","article-title":"The evolution of total knee and hip joint arthroplasty","volume":"54","author":"Song","year":"2011","journal-title":"J. Korean Med. Assoc."},{"issue":"2 Suppl","key":"10.1016\/j.msec.2019.02.082_bb0040","first-page":"s207","article-title":"The clinical history and development of the low contact stress total knee arthroplasty","volume":"25","author":"Sorrells","year":"2002","journal-title":"Orthopedics"},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0045","first-page":"147","article-title":"New Jersey low contact stress knee replacement system. Ten-year evaluation of meniscal bearings","volume":"20","author":"Buechel","year":"1989","journal-title":"Orthop. Clin. North Am."},{"issue":"6","key":"10.1016\/j.msec.2019.02.082_bb0050","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1007\/s00167-014-2865-0","article-title":"Post-operative Oxford knee score can be used to indicate whether patient expectations have been achieved after primary total knee arthroplasty","volume":"23","author":"Clement","year":"2015","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0055","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1055\/s-0034-1374812","article-title":"Bicruciate-retaining total knee arthroplasty: a review","volume":"27","author":"Cherian","year":"2014","journal-title":"J. Knee Surg."},{"issue":"12","key":"10.1016\/j.msec.2019.02.082_bb0060","doi-asserted-by":"crossref","first-page":"2315","DOI":"10.1016\/j.arth.2015.06.021","article-title":"Anteroposterior laxity after bicruciate-retaining total knee arthroplasty is closer to the native knee than ACL-resecting TKA: a biomechanical cadaver study","volume":"30","author":"Halewood","year":"2015","journal-title":"J. Arthroplast."},{"key":"10.1016\/j.msec.2019.02.082_bb0065","series-title":"Vanguard XP Total Knee System","author":"Biomet","year":"2017"},{"issue":"9","key":"10.1016\/j.msec.2019.02.082_bb0070","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1302\/2046-3758.69.BJR-2016-0250.R1","article-title":"Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model","volume":"6","author":"Koh","year":"2017","journal-title":"Bone Joint Res."},{"issue":"5","key":"10.1016\/j.msec.2019.02.082_bb0075","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1054\/arth.2000.4638","article-title":"The cruciate ligaments in total knee arthroplasty: a kinematic analysis of 2 total knee arthroplasties","volume":"15","author":"Stiehl","year":"2000","journal-title":"J. Arthroplast."},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0080","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s00167-006-0134-6","article-title":"Comparing in vivo kinematics of anterior cruciate-retaining and posterior cruciate-retaining total knee arthroplasty","volume":"15","author":"Moro-oka","year":"2007","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0085","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0883-5403(97)90026-7","article-title":"In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties","volume":"12","author":"Banks","year":"1997","journal-title":"J. Arthroplast."},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0090","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.arth.2015.07.041","article-title":"Patient-specific total knees demonstrate a higher manipulation rate compared to \u201cOff-the-Shelf Implants\u201d","volume":"31","author":"White","year":"2016","journal-title":"J. Arthroplast."},{"issue":"5","key":"10.1016\/j.msec.2019.02.082_bb0095","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.2106\/JBJS.H.00434","article-title":"Overhang of the femoral component in total knee arthroplasty: risk factors and clinical consequences","volume":"92","author":"Mahoney","year":"2010","journal-title":"J. Bone Joint Surg. Am."},{"issue":"6","key":"10.1016\/j.msec.2019.02.082_bb0100","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.knee.2016.07.002","article-title":"Morphometry of femoral rotation for total knee prosthesis according to gender in a Korean population using three-dimensional magnetic resonance imaging","volume":"23","author":"Kang","year":"2016","journal-title":"Knee"},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0105","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.knee.2016.09.012","article-title":"Effects of measurement methods for tibial rotation axis on the morphometry in Korean populations by gender","volume":"24","author":"Kang","year":"2017","journal-title":"Knee"},{"issue":"4","key":"10.1016\/j.msec.2019.02.082_bb0110","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1016\/j.arth.2016.09.034","article-title":"Customized versus patient-sized cruciate-retaining total knee arthroplasty: an in vivo kinematics study using mobile fluoroscopy","volume":"32","author":"Zeller","year":"2017","journal-title":"J. Arthroplast."},{"key":"10.1016\/j.msec.2019.02.082_bb0115","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1097\/00003086-199712000-00012","article-title":"Survivorship of cemented total knee arthroplasty","volume":"345","author":"Font-Rodriguez","year":"1997","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.msec.2019.02.082_bb0120","first-page":"136","article-title":"Long-term survival analysis of a posterior cruciate-retaining total condylar total knee arthroplasty","volume":"309","author":"Ritter","year":"1994","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"6","key":"10.1016\/j.msec.2019.02.082_bb0125","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1302\/0301-620X.78B6.0780907","article-title":"Kinematic condylar total knee arthroplasty. 14-year survivorship analysis of 208 consecutive cases","volume":"78","author":"Weir","year":"1996","journal-title":"J. Bone Joint Surg."},{"issue":"22","key":"10.1016\/j.msec.2019.02.082_bb0130","doi-asserted-by":"crossref","first-page":"2072","DOI":"10.2106\/JBJS.J.01143","article-title":"Increased long-term survival of posterior cruciate-retaining versus posterior cruciate-stabilizing total knee replacements","volume":"93","author":"Abdel","year":"2011","journal-title":"J. Bone Joint Surg. Am."},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0135","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1093\/rheumatology\/kem308","article-title":"The epidemiology of total knee replacement in South Korea: national registry data","volume":"47","author":"Kim","year":"2008","journal-title":"Rheumatology (Oxford, England)"},{"issue":"10","key":"10.1016\/j.msec.2019.02.082_bb0140","doi-asserted-by":"crossref","first-page":"898","DOI":"10.4065\/mcp.2010.0115","article-title":"A population-based study of trends in the use of total hip and total knee arthroplasty, 1969\u20132008","volume":"85","author":"Singh","year":"2010","journal-title":"Mayo Clin. Proc."},{"key":"10.1016\/j.msec.2019.02.082_bb0145","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/00003086-200211000-00003","article-title":"Insall Award paper. Why are total knee arthroplasties failing today?","volume":"404","author":"Sharkey","year":"2002","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0150","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1007\/s11999-009-0945-0","article-title":"The epidemiology of revision total knee arthroplasty in the United States","volume":"468","author":"Bozic","year":"2010","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.msec.2019.02.082_bb0155","first-page":"26","year":"2016","journal-title":"American Joint Replacement Registry"},{"issue":"1s","key":"10.1016\/j.msec.2019.02.082_bb0160","doi-asserted-by":"crossref","first-page":"S21","DOI":"10.1016\/j.otsr.2016.06.024","article-title":"How does total knee replacement technique influence polyethylene wear?","volume":"103","author":"Massin","year":"2017","journal-title":"Orthop. Traumatol. Surg. Res."},{"issue":"8 Suppl","key":"10.1016\/j.msec.2019.02.082_bb0165","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.arth.2013.04.056","article-title":"Why are total knees failing today? Etiology of total knee revision in 2010 and 2011","volume":"28","author":"Schroer","year":"2013","journal-title":"J. Arthroplast."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0170","doi-asserted-by":"crossref","first-page":"143","DOI":"10.5435\/00124635-201103000-00003","article-title":"The use of highly cross-linked polyethylene in total knee arthroplasty","volume":"19","author":"Lachiewicz","year":"2011","journal-title":"J. Am. Acad. Orthop. Surg."},{"issue":"8 Suppl","key":"10.1016\/j.msec.2019.02.082_bb0175","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.arth.2013.04.051","article-title":"Why are total knee arthroplasties being revised?","volume":"28","author":"Dalury","year":"2013","journal-title":"J. Arthroplast."},{"issue":"4","key":"10.1016\/j.msec.2019.02.082_bb0180","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1007\/s11999-008-0628-2","article-title":"Cross-linked compared with historical polyethylene in THA: an 8-year clinical study","volume":"467","author":"Geerdink","year":"2009","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.msec.2019.02.082_bb0185","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1097\/BLO.0b013e31815760b1","article-title":"Minimum 6-year followup of highly cross-linked polyethylene in THA","volume":"465","author":"Bragdon","year":"2007","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0190","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1016\/j.arth.2013.07.034","article-title":"10-year follow-up wear analysis of first-generation highly crosslinked polyethylene in primary total hip arthroplasty","volume":"29","author":"Snir","year":"2014","journal-title":"J. Arthroplast."},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0195","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1007\/s11999-014-3735-2","article-title":"The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial","volume":"473","author":"Glyn-Jones","year":"2015","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"8","key":"10.1016\/j.msec.2019.02.082_bb0200","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.arth.2012.03.048","article-title":"A prospective, randomized study of cross-linked and non\u2013cross-linked polyethylene for total hip arthroplasty at 10-year follow-up","volume":"27","author":"Engh","year":"2012","journal-title":"J. Arthroplast"},{"issue":"5","key":"10.1016\/j.msec.2019.02.082_bb0205","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.arth.2012.12.005","article-title":"Total hip arthroplasty using highly cross-linked polyethylene in patients younger than 50 years with minimum 10-year follow-up","volume":"28","author":"Babovic","year":"2013","journal-title":"J. Arthroplast."},{"issue":"8","key":"10.1016\/j.msec.2019.02.082_bb0210","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1302\/0301-620X.99B8.BJJ-2017-0028.R1","article-title":"j journal, The use of highly crosslinked polyethylene in total knee arthroplasty","volume":"99","author":"Brown","year":"2017","journal-title":"Bone Joint J."},{"key":"10.1016\/j.msec.2019.02.082_bb0215","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/01.blo.0000185310.59202.e5","article-title":"Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene","volume":"440","author":"Ries","year":"2005","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0220","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1002\/jor.1100170203","article-title":"Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements","volume":"17","author":"McKellop","year":"1999","journal-title":"J. Orthop. Res."},{"issue":"Suppl 2(Pt 1)","key":"10.1016\/j.msec.2019.02.082_bb0225","doi-asserted-by":"crossref","first-page":"27","DOI":"10.2106\/00004623-200100021-00007","article-title":"New polys for old: contribution or caveat?","volume":"83-A","author":"Greenwald","year":"2001","journal-title":"J. Bone Joint Surg. Am."},{"issue":"7 Suppl","key":"10.1016\/j.msec.2019.02.082_bb0230","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.arth.2008.06.017","article-title":"Highly cross-linked polyethylene in total knee arthroplasty: in the affirmative","volume":"23","author":"Jacofsky","year":"2008","journal-title":"J. Arthroplast."},{"issue":"10","key":"10.1016\/j.msec.2019.02.082_bb0235","doi-asserted-by":"crossref","first-page":"2021","DOI":"10.1002\/jor.20223","article-title":"Wear and toughness of crosslinked polyethylene for total knee replacements: a study using a simulator and small-punch testing","volume":"24","author":"Akagi","year":"2006","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.msec.2019.02.082_bb0240","first-page":"329","article-title":"Can sequentially-irradiated and annealed highly cross-linked polyethylene inserts thinner than eight-millimeters be utilized in total knee arthroplasty?","volume":"26","author":"Sayeed","year":"2015","journal-title":"Surg. Technol. Int."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0245","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1002\/jbm.a.33297","article-title":"In vitro wear performance of standard, crosslinked, and vitamin-E-blended UHMWPE","volume":"100","author":"Affatato","year":"2012","journal-title":"J. Biomed. Mater. Res. A"},{"key":"10.1016\/j.msec.2019.02.082_bb0250","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.jmbbm.2012.12.006","article-title":"The antioxidant and non-antioxidant contributions of vitamin E in vitamin E blended ultra-high molecular weight polyethylene for total knee replacement","volume":"31","author":"Turner","year":"2014","journal-title":"J. Mech. Behav. Biomed. Mater."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0255","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1002\/jbm.b.32904","article-title":"Analysis of wear, wear particles, and reduced inflammatory potential of vitamin E ultrahigh-molecular-weight polyethylene for use in total joint replacement","volume":"101","author":"Bladen","year":"2013","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0260","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1002\/jbm.b.32887","article-title":"Clinical trade-offs in cross-linked ultrahigh-molecular-weight polyethylene used in total joint arthroplasty","volume":"101","author":"Pruitt","year":"2013","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"issue":"7","key":"10.1016\/j.msec.2019.02.082_bb0265","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/j.jmbbm.2011.03.012","article-title":"Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene","volume":"4","author":"Atwood","year":"2011","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.msec.2019.02.082_bb0270","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/01.blo.0000148576.70780.13","article-title":"Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator","volume":"428","author":"Ezzet","year":"2004","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"32","key":"10.1016\/j.msec.2019.02.082_bb0275","doi-asserted-by":"crossref","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","article-title":"PEEK biomaterials in trauma, orthopedic, and spinal implants","volume":"28","author":"Kurtz","year":"2007","journal-title":"Biomaterials"},{"key":"10.1016\/j.msec.2019.02.082_bb0280","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1186\/1471-2482-10-10","article-title":"Anterior cervical discectomy with fusion in patients with cervical disc degeneration: a prospective outcome study of 258 patients (181 fused with autologous bone graft and 77 fused with a PEEK cage)","volume":"10","author":"Lied","year":"2010","journal-title":"BMC Surg."},{"issue":"5","key":"10.1016\/j.msec.2019.02.082_bb0285","first-page":"310","article-title":"Outcomes of interbody fusion cages used in 1 and 2-levels anterior cervical discectomy and fusion: titanium cages versus polyetheretherketone (PEEK) cages","volume":"23","author":"Niu","year":"2010","journal-title":"Clinical Spine Surgery"},{"issue":"4","key":"10.1016\/j.msec.2019.02.082_bb0290","doi-asserted-by":"crossref","first-page":"E208","DOI":"10.1097\/BSD.0b013e31826851a4","article-title":"PEEK versus Ti interbody fusion devices: resultant fusion, bone apposition, initial and 26-week biomechanics","volume":"29","author":"Pelletier","year":"2016","journal-title":"Clin. Spine Surg."},{"key":"10.1016\/j.msec.2019.02.082_bb0295","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.compositesb.2017.07.052","article-title":"Biomechanical evaluation of pedicle screw fixation system in spinal adjacent levels using polyetheretherketone, carbon-fiber-reinforced polyetheretherketone, and traditional titanium as rod materials","volume":"130","author":"Kang","year":"2017","journal-title":"Compos. Part B."},{"key":"10.1016\/j.msec.2019.02.082_bb0300","article-title":"PEEK usage climbs for devices","author":"Kostecki","year":"2011","journal-title":"Med. Des."},{"key":"10.1016\/j.msec.2019.02.082_bb0305","series-title":"Manufacturing Processes for Advanced Composites","author":"Campbell","year":"2003"},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0310","first-page":"3","article-title":"Composite materials for biomedical applications: a review","volume":"1","author":"Salernitano","year":"2003","journal-title":"J. Appl. Biomater. Biomech."},{"issue":"11","key":"10.1016\/j.msec.2019.02.082_bb0315","doi-asserted-by":"crossref","first-page":"2362","DOI":"10.1007\/s11999-016-4960-7","article-title":"Editorial comment: advances in PEEK technology","volume":"474","author":"Kurtz","year":"2016","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.msec.2019.02.082_bb0320","doi-asserted-by":"crossref","first-page":"33","DOI":"10.4137\/CMAMD.S20354","article-title":"The use of carbon-fiber-reinforced (CFR) PEEK material in orthopedic implants: a systematic review","volume":"8","author":"Li","year":"2015","journal-title":"Clin. Med. Insights Arthritis Musculoskelet. Disord."},{"key":"10.1016\/j.msec.2019.02.082_bb0325","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/j.compositesb.2015.07.019","article-title":"Advanced biomaterials in hip joint arthroplasty. A review on polymer and ceramics composites as alternative bearings","volume":"83","author":"Affatato","year":"2015","journal-title":"J. Compos. Part B."},{"issue":"4","key":"10.1016\/j.msec.2019.02.082_bb0330","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/S0883-5403(08)80093-9","article-title":"Tissue response in relation to type of wear particles around failed hip arthroplasties","volume":"5","author":"Howie","year":"1990","journal-title":"J. Arthroplast."},{"issue":"5","key":"10.1016\/j.msec.2019.02.082_bb0335","first-page":"1","volume":"12","year":"1994","journal-title":"NIH Consens. Statement"},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0340","doi-asserted-by":"crossref","first-page":"113","DOI":"10.3109\/17453679408993734","article-title":"Osteolysis and particle disease in hip replacement. A review","volume":"65","author":"Harris","year":"1994","journal-title":"Acta Orthop. Scand."},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0345","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1002\/jbm.b.31974","article-title":"Macrophage reactivity to different polymers demonstrates particle size- and material-specific reactivity: PEEK-OPTIMA((R)) particles versus UHMWPE particles in the submicron, micron, and 10 micron size ranges","volume":"100","author":"Hallab","year":"2012","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"issue":"11","key":"10.1016\/j.msec.2019.02.082_bb0350","doi-asserted-by":"crossref","first-page":"4296","DOI":"10.1016\/j.actbio.2010.06.002","article-title":"Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo","volume":"6","author":"Utzschneider","year":"2010","journal-title":"Acta Biomater."},{"issue":"Suppl. 4","key":"10.1016\/j.msec.2019.02.082_bb0355","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/S0020-1383(00)80019-4","article-title":"Nonresorbable polymers in bone surgery","volume":"31","author":"Eschbach","year":"2000","journal-title":"Injury."},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0360","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1007\/s10856-013-5037-8","article-title":"Elevated cytokine expression of different PEEK wear particles compared to UHMWPE in vivo","volume":"25","author":"Lorber","year":"2014","journal-title":"J. Mater. Sci. Mater. Med."},{"issue":"11","key":"10.1016\/j.msec.2019.02.082_bb0365","doi-asserted-by":"crossref","first-page":"3689","DOI":"10.1002\/jbm.a.35480","article-title":"Biomechanical and bioactivity concepts of polyetheretherketone composites for use in orthopedic implants-a review","volume":"103","author":"Abdullah","year":"2015","journal-title":"J. Biomed. Mater. Res. A"},{"issue":"11","key":"10.1016\/j.msec.2019.02.082_bb0370","doi-asserted-by":"crossref","first-page":"2394","DOI":"10.1007\/s11999-016-4976-z","article-title":"The biologic response to polyetheretherketone (PEEK) wear particles in total joint replacement: a systematic review","volume":"474","author":"Stratton-Powell","year":"2016","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"11","key":"10.1016\/j.msec.2019.02.082_bb0375","doi-asserted-by":"crossref","first-page":"2428","DOI":"10.1007\/s11999-016-5041-7","article-title":"Are PEEK-on-ceramic bearings an option for total disc arthroplasty? an in vitro tribology study","volume":"474","author":"Siskey","year":"2016","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.msec.2019.02.082_bb0380","series-title":"14th Annual Report 2017, National Joint Registry for England, Wales, Northern Ireland and the Isle of Man","year":"2016"},{"key":"10.1016\/j.msec.2019.02.082_bb0385","series-title":"Inc., AS Advanced Surface 7 Layers to Protect You","author":"Braun","year":"2019"},{"issue":"3\u20134","key":"10.1016\/j.msec.2019.02.082_bb0390","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.wear.2007.03.020","article-title":"UHMWPE wear against roughened oxidized zirconium and CoCr femoral knee components during force-controlled simulation","volume":"264","author":"DesJardins","year":"2008","journal-title":"Wear."},{"key":"10.1016\/j.msec.2019.02.082_bb0395","series-title":"Inc., 30 Year Wear Performance of LEGION Primary Knees With VERILAST Technology","author":"Smith","year":"2010"},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0400","first-page":"1","article-title":"Wear-reduction technology in total knee arthroplasty","volume":"1","author":"Haas","year":"2010","journal-title":"Bone & Joint Science"},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0405","doi-asserted-by":"crossref","first-page":"475","DOI":"10.3390\/lubricants3020475","article-title":"Design of an advanced bearing system for total knee arthroplasty","volume":"3","author":"Morrison","year":"2015","journal-title":"Lubricants"},{"key":"10.1016\/j.msec.2019.02.082_bb0410","series-title":"ORS 2011 Annual Meeting","article-title":"Long-term wear performance of an advanced bearing technology for TKA","author":"Papannagari","year":"2011"},{"issue":"7","key":"10.1016\/j.msec.2019.02.082_bb0415","doi-asserted-by":"crossref","first-page":"2434","DOI":"10.1016\/j.actbio.2012.03.029","article-title":"What's next? Alternative materials for articulation in total joint replacement","volume":"8","author":"Sonntag","year":"2012","journal-title":"Acta Biomater."},{"issue":"9\u201310","key":"10.1016\/j.msec.2019.02.082_bb0420","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1016\/j.wear.2004.07.010","article-title":"Tribological behaviour of carbon-nanofibre-reinforced poly (ether ether ketone)","volume":"257","author":"Werner","year":"2004","journal-title":"Wear."},{"issue":"8","key":"10.1016\/j.msec.2019.02.082_bb0425","doi-asserted-by":"crossref","first-page":"1430","DOI":"10.1016\/j.triboint.2010.01.020","article-title":"A correlation between the tribological and mechanical properties of short carbon fibers reinforced PEEK materials with different fiber orientations","volume":"43","author":"Rasheva","year":"2010","journal-title":"Tribol. Int."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0430","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1243\/09544119JEIM224","article-title":"The wear properties of CFR-PEEK-OPTIMA articulating against ceramic assessed on a multidirectional pin-on-plate machine","volume":"221","author":"Scholes","year":"2007","journal-title":"Proc. Inst. Mech. Eng. H J. Eng. Med."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0435","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1177\/0954411915576353","article-title":"Wear of PEEK-OPTIMA(R) and PEEK-OPTIMA(R)-Wear Performance articulating against highly cross-linked polyethylene","volume":"229","author":"East","year":"2015","journal-title":"Proc. Inst. Mech. Eng. H J. Eng. Med."},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0440","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/s10856-008-3558-3","article-title":"Wear studies on the likely performance of CFR-PEEK\/CoCrMo for use as artificial joint bearing materials","volume":"20","author":"Scholes","year":"2009","journal-title":"J. Mater. Sci. Mater. Med."},{"key":"10.1016\/j.msec.2019.02.082_bb0445","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.jmbbm.2016.06.005","article-title":"Influence of contact pressure, cross-shear and counterface material on the wear of PEEK and CFR-PEEK for orthopaedic applications","volume":"63","author":"Brockett","year":"2016","journal-title":"J. Mech. Behav. Biomed. Mater."},{"issue":"3\u20134","key":"10.1016\/j.msec.2019.02.082_bb0450","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1016\/j.wear.2009.08.023","article-title":"The wear performance of PEEK-OPTIMA based self-mating couples","volume":"268","author":"Scholes","year":"2010","journal-title":"Wear."},{"issue":"3\u20134","key":"10.1016\/j.msec.2019.02.082_bb0455","first-page":"241","article-title":"A multi-directional wear screening device and preliminary results of UHMWPE articulating against stainless steel","volume":"10","author":"Joyce","year":"2000","journal-title":"Biomed. Mater. Eng."},{"issue":"6","key":"10.1016\/j.msec.2019.02.082_bb0460","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1177\/0954411914538783","article-title":"The influence of nominal stress on wear factors of carbon fibre-reinforced polyetheretherketone (PEEK-OPTIMA(R) Wear Performance) against zirconia toughened alumina (Biolox(R) delta ceramic)","volume":"228","author":"Evans","year":"2014","journal-title":"Proc. Inst. Mech. Eng. H J. Eng. Med."},{"issue":"6","key":"10.1016\/j.msec.2019.02.082_bb0465","doi-asserted-by":"crossref","first-page":"1459","DOI":"10.1002\/jbm.b.32664","article-title":"Wear of ceramic-on-carbon fiber-reinforced poly-ether ether ketone hip replacements","volume":"100","author":"Brockett","year":"2012","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"issue":"7","key":"10.1016\/j.msec.2019.02.082_bb0470","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1243\/09544119JEIM733","article-title":"In vitro friction and lubrication of large bearing hip prostheses","volume":"224","author":"Flanagan","year":"2010","journal-title":"Proc. Inst. Mech. Eng. H J. Eng. Med."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0475","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1243\/09544119JEIM334","article-title":"Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head","volume":"222","author":"Scholes","year":"2008","journal-title":"Proc. Inst. Mech. Eng. H J. Eng. Med."},{"issue":"9","key":"10.1016\/j.msec.2019.02.082_bb0480","doi-asserted-by":"crossref","first-page":"3601","DOI":"10.1016\/j.actbio.2010.04.003","article-title":"Biotribology of alternative bearing materials for unicompartmental knee arthroplasty","volume":"6","author":"Grupp","year":"2010","journal-title":"Acta Biomater."},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0485","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1243\/09544119JEIM471","article-title":"Pitch-based carbon-fibre-reinforced poly (ether\u2014ether\u2014ketone) OPTIMA\u00ae assessed as a bearing material in a mobile bearing unicondylar knee joint","volume":"223","author":"Scholes","year":"2009","journal-title":"Proc. Inst. Mech. Eng. H J. Eng. Med."},{"key":"10.1016\/j.msec.2019.02.082_bb0490","series-title":"ORS Annual Meeting","article-title":"PEEK and CFR PEEK as an alternative to UHMWPE in total knee replacement","author":"Carbone","year":"2015"},{"key":"10.1016\/j.msec.2019.02.082_bb0495","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.wear.2016.12.010","article-title":"PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: An experimental wear study","volume":"374\u2013375","author":"Brockett","year":"2017","journal-title":"Wear."},{"issue":"4","key":"10.1016\/j.msec.2019.02.082_bb0505","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1007\/s10856-007-3256-6","article-title":"Pre-clinical studies to validate the MITCH PCR Cup: a flexible and anatomically shaped acetabular component with novel bearing characteristics","volume":"19","author":"Latif","year":"2008","journal-title":"J. Mater. Sci. Mater. Med."},{"issue":"11","key":"10.1016\/j.msec.2019.02.082_bb0510","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/S0301-679X(98)00088-7","article-title":"Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement","volume":"31","author":"Wang","year":"1998","journal-title":"Tribol. Int."},{"key":"10.1016\/j.msec.2019.02.082_bb0515","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1016\/S0043-1648(99)00026-5","article-title":"Suitability and limitations of carbon fiber reinforced PEEK composites as bearing surfaces for total joint replacements","volume":"225","author":"Wang","year":"1999","journal-title":"J. Wear."},{"key":"10.1016\/j.msec.2019.02.082_bb0520","series-title":"Proceedings of the Transactions of the AAOS Meeting","article-title":"Revisiting the clinical and wear performance of poly II tibial inserts after long-term implantation","author":"Medel","year":"2009"},{"key":"10.1016\/j.msec.2019.02.082_bb0525","first-page":"119","article-title":"An improved bearing material for joint replacement prostheses: carbon fiber-reinforced UHMW polyethylene","volume":"3","author":"Ainsworth","year":"1977","journal-title":"Transactions of Society for Biomaterials"},{"issue":"5","key":"10.1016\/j.msec.2019.02.082_bb0530","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1002\/jbm.820150508","article-title":"The effect of carbon fiber reinforcement on contact area, contact pressure, and time-dependent deformation in polyethylene tibial components","volume":"15","author":"Wright","year":"1981","journal-title":"J. Biomed. Mater. Res."},{"key":"10.1016\/j.msec.2019.02.082_bb0535","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1097\/00003086-198509000-00033","article-title":"Granulomatous reaction and cystic bony destruction associated with high wear rate in a total knee prosthesis","volume":"198","author":"Dannenmaier","year":"1985","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.msec.2019.02.082_bb0540","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/00003086-199402000-00005","article-title":"Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty","volume":"299","author":"Wasielewski","year":"1994","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"31","key":"10.1016\/j.msec.2019.02.082_bb0545","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/S0021-9290(98)80098-5","article-title":"Composites as bearing partner in total knee replacement: failure analysis of POLY-II components with respect to the material design","volume":"1001","author":"Birken","year":"1998","journal-title":"J. Biomech."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0550","first-page":"263","article-title":"Wear in carbon fiber-reinforced polyethylene (poly-two) knee prostheses","volume":"81","author":"Busanelli","year":"1996","journal-title":"Chir. Organi Mov."},{"issue":"5","key":"10.1016\/j.msec.2019.02.082_bb0555","first-page":"915","article-title":"Radiophosphate visualization of the foreign body reaction to wear debris from total knee prosthesis","volume":"28","author":"Rosenthall","year":"1987","journal-title":"J. Nucl. Med."},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0560","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1002\/jor.1100020202","article-title":"Fatigue crack propagation behavior of ultrahigh molecular weight polyethylene","volume":"2","author":"Connelly","year":"1984","journal-title":"J. Orthop. Res."},{"issue":"6","key":"10.1016\/j.msec.2019.02.082_bb0565","doi-asserted-by":"crossref","first-page":"926","DOI":"10.2106\/00004623-198870060-00019","article-title":"Failure of carbon fiber-reinforced polyethylene total knee-replacement components. A report of two cases","volume":"70","author":"Wright","year":"1988","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.msec.2019.02.082_bb0570","series-title":"International Biomaterials Symposium","first-page":"285","article-title":"Fiber reinforcement of ultrahigh molecular weight polyethylene,Transactions of the annual meeting of the society for biomaterials","volume":"1991","author":"Meyer","year":"1991"},{"issue":"10","key":"10.1016\/j.msec.2019.02.082_bb0575","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1002\/jbm.820281012","article-title":"Long-term durability of the interface in FRP composites after exposure to simulated physiologic saline environments","volume":"28","author":"Meyer","year":"1994","journal-title":"J. Biomed. Mater. Res."},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0580","first-page":"162","article-title":"Water absorption and fiber-matrix interface durability in carbon-PEEK","volume":"13","author":"Zhang","year":"2000","journal-title":"Sage."},{"issue":"10","key":"10.1016\/j.msec.2019.02.082_bb0585","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1023\/A:1018515318630","article-title":"The influence of stress conditions on the wear of UHMWPE for total joint replacements","volume":"8","author":"Barbour","year":"1997","journal-title":"J. Mater. Sci. Mater. Med."},{"issue":"12","key":"10.1016\/j.msec.2019.02.082_bb0590","doi-asserted-by":"crossref","first-page":"1898","DOI":"10.1016\/j.jbiomech.2009.05.010","article-title":"Effect of conformity and contact stress on wear in fixed-bearing total knee prostheses","volume":"42","author":"Galvin","year":"2009","journal-title":"J. Biomech."},{"issue":"7","key":"10.1016\/j.msec.2019.02.082_bb0595","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1007\/s10856-017-5916-5","article-title":"Wear predictions for UHMWPE material with various surface properties used on the femoral component in total knee arthroplasty: a computational simulation study","volume":"28","author":"Kang","year":"2017","journal-title":"J. Mater. Sci. Mater. Med."},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0600","doi-asserted-by":"crossref","DOI":"10.1115\/1.2838030","article-title":"Predicting knee replacement damage in a simulator machine using a computational model with a consistent wear factor","volume":"130","author":"Zhao","year":"2008","journal-title":"J. Biomech. Eng."},{"issue":"8","key":"10.1016\/j.msec.2019.02.082_bb0605","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1063\/1.1721448","article-title":"Contact and rubbing of flat surfaces","volume":"24","author":"Archard","year":"1953","journal-title":"J. Appl. Phys."},{"issue":"7","key":"10.1016\/j.msec.2019.02.082_bb0610","doi-asserted-by":"crossref","first-page":"1550","DOI":"10.1016\/j.jbiomech.2006.07.027","article-title":"Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading","volume":"40","author":"Knight","year":"2007","journal-title":"J. Biomech."},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0615","doi-asserted-by":"crossref","first-page":"381","DOI":"10.3390\/lubricants3020381","article-title":"Prediction of wear in crosslinked polyethylene unicompartmental knee arthroplasty","volume":"3","author":"Netter","year":"2015","journal-title":"Lubricants."},{"issue":"7\u20138","key":"10.1016\/j.msec.2019.02.082_bb0620","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1016\/j.wear.2007.06.010","article-title":"Probabilistic computational modeling of total knee replacement wear","volume":"264","author":"Pal","year":"2008","journal-title":"Wear."},{"key":"10.1016\/j.msec.2019.02.082_bb0625","series-title":"ISTA Seoul","article-title":"Comparison of wear with respect to different materials for tibial insert: UHMWPE, PEEK and CFR-PEEK in total knee arthroplasty using finite-element analysis","author":"Kang","year":"2017"},{"issue":"9","key":"10.1016\/j.msec.2019.02.082_bb0630","doi-asserted-by":"crossref","first-page":"2219","DOI":"10.1016\/j.carbon.2009.04.012","article-title":"Numerical simulation of wear in a C\/C composite multidisk clutch","volume":"47","author":"Zhao","year":"2009","journal-title":"J. Carbon."},{"issue":"4","key":"10.1016\/j.msec.2019.02.082_bb0635","doi-asserted-by":"crossref","first-page":"193","DOI":"10.3390\/lubricants2040193","article-title":"Development and validation of a wear model to predict polyethylene wear in a total knee arthroplasty: a finite element analysis","volume":"2","author":"Innocenti","year":"2014","journal-title":"Lubricants."},{"key":"10.1016\/j.msec.2019.02.082_bb0640","series-title":"Friction and Wear","author":"Sarkar","year":"1980"},{"key":"10.1016\/j.msec.2019.02.082_bb0645","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/j.triboint.2016.10.050","article-title":"A patient-specific wear prediction framework for an artificial knee joint with coupled musculoskeletal multibody-dynamics and finite element analysis","volume":"109","author":"Zhang","year":"2017","journal-title":"Tribol. Int."},{"key":"10.1016\/j.msec.2019.02.082_bb0650","series-title":"52nd Annual Meeting of the Orthopaedic Research Society","first-page":"19","article-title":"Influence of cross shear on the wear of TKA under various kinematic conditions","author":"Knight","year":"2006"},{"key":"10.1016\/j.msec.2019.02.082_bb0655","series-title":"Australian Orthopaedic Association National Joint Replacement Registry","author":"Graves","year":"2014"},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0660","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s40634-017-0078-4","article-title":"A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait","volume":"4","author":"de Ruiter","year":"2017","journal-title":"J. Exp. Orthop."},{"issue":"8","key":"10.1016\/j.msec.2019.02.082_bb0665","doi-asserted-by":"crossref","first-page":"1681","DOI":"10.1016\/j.arth.2014.03.010","article-title":"Bone mineral density of the femur in autopsy retrieved total knee arthroplasties","volume":"29","author":"Lavernia","year":"2014","journal-title":"J. Arthroplast."},{"issue":"6","key":"10.1016\/j.msec.2019.02.082_bb0670","doi-asserted-by":"crossref","first-page":"630","DOI":"10.3109\/17453670209178027","article-title":"Stemmed femoral knee prostheses: effects of prosthetic design and fixation on bone loss","volume":"73","author":"van Lenthe","year":"2002","journal-title":"Acta Orthop. Scand."},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0675","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/0267-6605(93)90034-5","article-title":"Evaluation of wear in an all-polymer total knee replacement. Part 2: clinical evaluation of wear in a polyethylene on polyacetal total knee","volume":"14","author":"Bradley","year":"1993","journal-title":"Clin. Mater."},{"issue":"4","key":"10.1016\/j.msec.2019.02.082_bb0680","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/S0883-5403(98)90003-1","article-title":"Can a total knee replacement prosthesis be made entirely of polymers?","volume":"13","author":"Moore","year":"1998","journal-title":"J. Arthroplast."},{"issue":"11","key":"10.1016\/j.msec.2019.02.082_bb0685","doi-asserted-by":"crossref","first-page":"2405","DOI":"10.1007\/s11999-016-4801-8","article-title":"Does a PEEK femoral TKA implant preserve intact femoral surface strains compared with CoCr? A preliminary laboratory study","volume":"474","author":"Rankin","year":"2016","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"8","key":"10.1016\/j.msec.2019.02.082_bb0690","doi-asserted-by":"crossref","DOI":"10.1111\/aor.13101","article-title":"Feasibility and safety of a cemented PEEK-on-PE knee replacement in a goat model: a preliminary study","volume":"42","author":"Du","year":"2018","journal-title":"Artif. Organs"},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0695","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1111\/j.1525-1594.2011.01275.x","article-title":"Novel surface modifications of carbon fiber-reinforced polyetheretherketone hip stem in an ovine model","volume":"36","author":"Nakahara","year":"2012","journal-title":"Artif. Organs"},{"issue":"9","key":"10.1016\/j.msec.2019.02.082_bb0700","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1016\/j.arth.2014.04.014","article-title":"The distribution of implant fixation for femoral components of TKA: a postmortem retrieval study","volume":"29","author":"Howard","year":"2014","journal-title":"J. Arthroplast."},{"issue":"1","key":"10.1016\/j.msec.2019.02.082_bb0705","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1007\/s11999-013-3248-4","article-title":"Loss of cement-bone interlock in retrieved tibial components from total knee arthroplasties","volume":"472","author":"Miller","year":"2014","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"4","key":"10.1016\/j.msec.2019.02.082_bb0710","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/j.jbiomech.2011.12.008","article-title":"A new approach to quantify trabecular resorption adjacent to cemented knee arthroplasty","volume":"45","author":"Mann","year":"2012","journal-title":"J. Biomech."},{"issue":"6","key":"10.1016\/j.msec.2019.02.082_bb0715","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.2106\/00004623-200306000-00019","article-title":"A biomechanical analysis of polyethylene liner cementation into a fixed metal acetabular shell","volume":"85","author":"Haft","year":"2003","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.msec.2019.02.082_bb0720","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.medengphy.2017.06.039","article-title":"Fixation strength of a polyetheretherketone femoral component in total knee arthroplasty","volume":"49","author":"de Ruiter","year":"2017","journal-title":"Med. Eng. Phys."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0725","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1515\/bmt-2014-0090","article-title":"Adhesive strength of total knee endoprostheses to bone cement - analysis of metallic and ceramic femoral components under worst-case conditions Biomedizinische Technik","volume":"61","author":"Bergschmidt","year":"2016","journal-title":"Biomed. Eng."},{"issue":"11","key":"10.1016\/j.msec.2019.02.082_bb0730","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1177\/0954411916667410","article-title":"PEEK-OPTIMA\u2122 as an alternative to cobalt chrome in the femoral component of total knee replacement: a preliminary study","volume":"230","author":"Cowie","year":"2016","journal-title":"Proc. Inst. Mech. Eng. H J. Eng. Med."},{"key":"10.1016\/j.msec.2019.02.082_bb0735","doi-asserted-by":"crossref","first-page":"948520","DOI":"10.1155\/2014\/948520","article-title":"Early results of a new rotating hinge knee implant","volume":"2014","author":"Giurea","year":"2014","journal-title":"Biomed. Res. Int."},{"key":"10.1016\/j.msec.2019.02.082_bb0740","doi-asserted-by":"crossref","DOI":"10.1155\/2016\/7032830","article-title":"Analysis of carbon fiber reinforced PEEK hinge mechanism articulation components in a rotating hinge knee design: a comparison of in vitro and retrieval findings","volume":"2016","author":"Schierjott","year":"2016","journal-title":"Biomed. Res. Int."},{"key":"10.1016\/j.msec.2019.02.082_bb0745","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1097\/00003086-200111000-00038","article-title":"Evolution of the rotating hinge for complex total knee arthroplasty","volume":"392","author":"Barrack","year":"2001","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"10","key":"10.1016\/j.msec.2019.02.082_bb0750","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.3928\/0147-7447-20021001-11","article-title":"Rise of the rotating hinge in revision total knee arthroplasty","volume":"25","author":"Barrack","year":"2002","journal-title":"Orthopedics."},{"issue":"11","key":"10.1016\/j.msec.2019.02.082_bb0755","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1007\/s00402-011-1330-5","article-title":"Implant survival and outcome after rotating-hinge total knee revision arthroplasty: a minimum 6-year follow-up","volume":"131","author":"Gudnason","year":"2011","journal-title":"Arch. Orthop. Trauma Surg."},{"issue":"6","key":"10.1016\/j.msec.2019.02.082_bb0760","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/S0883-5403(99)90231-0","article-title":"The effects of the rotating-hinge total knee replacement on gait and stair stepping","volume":"14","author":"Draganich","year":"1999","journal-title":"J. Arthroplast."},{"key":"10.1016\/j.msec.2019.02.082_bb0765","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/00003086-198911000-00003","article-title":"The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system","volume":"248","author":"Ewald","year":"1989","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0770","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1007\/s00167-003-0401-8","article-title":"Quality of life and clinical outcome in salvage revision total knee replacement: hinged vs total condylar design","volume":"12","author":"Fuchs","year":"2004","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"issue":"8","key":"10.1016\/j.msec.2019.02.082_bb0775","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1016\/S0883-5403(96)80132-X","article-title":"Clinical and radiographic results of the Total Condylar III and Constrained Condylar total knee arthroplasty","volume":"11","author":"Lachiewicz","year":"1996","journal-title":"J. Arthroplast."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0780","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s00167-011-1590-1","article-title":"Primary total knee arthroplasty using rotating-hinge prosthesis in severely affected knees","volume":"20","author":"Yang","year":"2012","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0785","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.arth.2006.11.020","article-title":"Dislocation of rotating-hinge knee prostheses with antidislocation mechanism","volume":"23","author":"Pacha-Vicente","year":"2008","journal-title":"J. Arthroplast."},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0790","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.arth.2012.04.029","article-title":"Repeated early failure of a newly designed hinged knee system","volume":"28","author":"Lee","year":"2013","journal-title":"J. Arthroplast."},{"issue":"3","key":"10.1016\/j.msec.2019.02.082_bb0795","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/S0883-5403(00)90877-5","article-title":"Early catastrophic failure of rotating hinge total knee prosthesis","volume":"15","author":"Wang","year":"2000","journal-title":"J. Arthroplast."},{"issue":"6","key":"10.1016\/j.msec.2019.02.082_bb0800","doi-asserted-by":"crossref","first-page":"7054","DOI":"10.1016\/j.actbio.2013.02.030","article-title":"Biotribology of a new bearing material combination in a rotating hinge knee articulation","volume":"9","author":"Grupp","year":"2013","journal-title":"Acta Biomater."},{"key":"10.1016\/j.msec.2019.02.082_bb0805","series-title":"Orthopaedic Proceedings","first-page":"223","article-title":"Evaluation of carbon-fibre-reinforced PEEK as material for intervertebral disc replacement","author":"Grupp","year":"2014"},{"issue":"2","key":"10.1016\/j.msec.2019.02.082_bb0810","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.arth.2017.09.025","article-title":"Influence of increased posterior tibial slope in total knee arthroplasty on knee joint biomechanics: a computational simulation study","volume":"33","author":"Kang","year":"2018","journal-title":"J. Arthroplast."}],"container-title":["Materials Science and Engineering: C"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S092849311831837X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S092849311831837X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,15]],"date-time":"2025-10-15T12:30:23Z","timestamp":1760531423000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S092849311831837X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7]]},"references-count":161,"alternative-id":["S092849311831837X"],"URL":"https:\/\/doi.org\/10.1016\/j.msec.2019.02.082","relation":{},"ISSN":["0928-4931"],"issn-type":[{"value":"0928-4931","type":"print"}],"subject":[],"published":{"date-parts":[[2019,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Total knee arthroplasty application of polyetheretherketone and carbon-fiber-reinforced polyetheretherketone: A review","name":"articletitle","label":"Article Title"},{"value":"Materials Science and Engineering: C","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.msec.2019.02.082","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}