{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T13:41:53Z","timestamp":1792676513874,"version":"4.5.0"},"reference-count":67,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T00:00:00Z","timestamp":1776384000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001665","name":"Agence Nationale de la Recherche","doi-asserted-by":"publisher","award":["ANR-23-CE17-0019"],"award-info":[{"award-number":["ANR-23-CE17-0019"]}],"id":[{"id":"10.13039\/501100001665","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100032449","name":"Fondation France Scl\u00e9rose en plaques","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100032449","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004794","name":"Centre National de la Recherche Scientifique","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004794","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Revue Neurologique"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1016\/j.neurol.2026.04.003","type":"journal-article","created":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T19:51:47Z","timestamp":1776973907000},"page":"358-372","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["7T magnetic resonance imaging of the human spinal cord in multiple sclerosis: Advances, insights and unmet needs"],"prefix":"10.1016","volume":"182","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0850-1742","authenticated-orcid":false,"given":"V.","family":"Callot","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Destruel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Demorti\u00e8re","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B.","family":"Testud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.neurol.2026.04.003_bib0340","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1016\/S1474-4422(25)00270-4","article-title":"Diagnosis of multiple sclerosis: 2024 revisions of the McDonald criteria","volume":"24","author":"Montalban","year":"2025","journal-title":"Lancet Neurol"},{"key":"10.1016\/j.neurol.2026.04.003_bib0345","doi-asserted-by":"crossref","first-page":"2131","DOI":"10.1002\/mrm.29391","article-title":"Magnetic field strength dependent SNR gain at the center of a spherical phantom and up to 11.7T","volume":"88","author":"Le Ster","year":"2022","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0350","doi-asserted-by":"crossref","first-page":"fcae359","DOI":"10.1093\/braincomms\/fcae359","article-title":"The use of 7T MRI in multiple sclerosis: review and consensus statement from the North American Imaging in Multiple Sclerosis Cooperative","volume":"6","author":"Harrison","year":"2024","journal-title":"Brain Commun"},{"key":"10.1016\/j.neurol.2026.04.003_bib0355","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.nic.2016.12.006","article-title":"Insights from ultrahigh field imaging in multiple sclerosis","volume":"27","author":"Schindler","year":"2017","journal-title":"Neuroimaging Clin N Am"},{"key":"10.1016\/j.neurol.2026.04.003_bib0360","doi-asserted-by":"crossref","first-page":"4995","DOI":"10.1007\/s00415-023-11829-5","article-title":"The added value of spinal cord lesions to disability accrual in multiple sclerosis","volume":"270","author":"Ruggieri","year":"2023","journal-title":"J Neurol"},{"key":"10.1016\/j.neurol.2026.04.003_bib0365","doi-asserted-by":"crossref","first-page":"e200333","DOI":"10.1212\/NXI.0000000000200333","article-title":"Microstructural damage and repair in the spinal cord of patients with early multiple sclerosis and association with disability at 5\u00a0years","volume":"12","author":"Gaubert","year":"2025","journal-title":"Neurol Neuroimmunol Neuroinflamm"},{"key":"10.1016\/j.neurol.2026.04.003_bib0370","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1038\/s41582-020-0314-x","article-title":"MAGNIMS consensus recommendations on the use of brain and spinal cord atrophy measures in clinical practice","volume":"16","author":"Sastre-Garriga","year":"2020","journal-title":"Nat Rev Neurol"},{"key":"10.1016\/j.neurol.2026.04.003_bib0375","doi-asserted-by":"crossref","DOI":"10.1177\/1756286419840593","article-title":"Advances in spinal cord imaging in multiple sclerosis","volume":"12","author":"Moccia","year":"2019","journal-title":"Ther Adv Neurol Disord"},{"key":"10.1016\/j.neurol.2026.04.003_bib0380","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1002\/nbm.1809","article-title":"High-resolution human cervical spinal cord imaging at 7T","volume":"25","author":"Sigmund","year":"2012","journal-title":"NMR Biomed"},{"key":"10.1016\/j.neurol.2026.04.003_bib0385","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.neuroimage.2016.08.055","article-title":"High-resolution multi-parametric quantitative magnetic resonance imaging of the human cervical spinal cord at 7T","volume":"143","author":"Massire","year":"2016","journal-title":"Neuroimage"},{"key":"10.1016\/j.neurol.2026.04.003_bib0390","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1177\/1352458515591070","article-title":"Magnetic resonance imaging of the cervical spinal cord in multiple sclerosis at 7T","volume":"22","author":"Dula","year":"2016","journal-title":"Mult Scler"},{"key":"10.1016\/j.neurol.2026.04.003_bib0395","series-title":"MRI of the thoracic spinal cord in multiple sclerosis at 7T","author":"Lefeuvre","year":"2016"},{"key":"10.1016\/j.neurol.2026.04.003_bib0400","doi-asserted-by":"crossref","first-page":"2973","DOI":"10.1093\/brain\/awaa249","article-title":"7T imaging reveals a gradient in spinal cord lesion distribution in multiple sclerosis","volume":"143","author":"Ouellette","year":"2020","journal-title":"Brain"},{"key":"10.1016\/j.neurol.2026.04.003_bib0405","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1093\/brain\/awv011","article-title":"A gradient in cortical pathology in multiple sclerosis by in vivo quantitative 7T imaging","volume":"138","author":"Mainero","year":"2015","journal-title":"Brain"},{"key":"10.1016\/j.neurol.2026.04.003_bib0410","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s00401-024-02700-6","article-title":"The prevalence and topography of spinal cord demyelination in multiple sclerosis: a retrospective study","volume":"147","author":"Waldman","year":"2024","journal-title":"Acta Neuropathol"},{"key":"10.1016\/j.neurol.2026.04.003_bib0415","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.3174\/ajnr.A7964","article-title":"Contribution of the MP2RAGE 7T sequence in MS lesions of the cervical spinal cord","volume":"44","author":"Testud","year":"2023","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.neurol.2026.04.003_bib0420","doi-asserted-by":"crossref","first-page":"116275","DOI":"10.1016\/j.neuroimage.2019.116275","article-title":"Anterior fissure, central canal, posterior septum and more: new insights into the cervical spinal cord gray and white matter regional organization using T1 mapping at 7T","volume":"205","author":"Massire","year":"2020","journal-title":"NeuroImage"},{"key":"10.1016\/j.neurol.2026.04.003_bib0425","doi-asserted-by":"crossref","DOI":"10.1097\/RLI.0000000000001288","article-title":"White and gray matter multiple sclerosis spinal cord lesion characteristics and individualized tissue damage assessment using 7T T1 mapping","author":"Laines Medina","year":"2026","journal-title":"Invest Radiol"},{"key":"10.1016\/j.neurol.2026.04.003_bib0430","series-title":"Spinal cord lesions in MS: Insights from combined ultra-high-resolution postmortem MRI and histology","author":"Tsagkas","year":"2025"},{"key":"10.1016\/j.neurol.2026.04.003_bib0435","series-title":"Automatic multi-contrast MRI segmentation of spinal cord lesions. Multiple Sclerosis Journal, vol. 31","author":"Benveniste","year":"2025"},{"key":"10.1016\/j.neurol.2026.04.003_bib0440","series-title":"Automatic multiple sclerosis lesion segmentation in the spinal cord on 3T and 7T MP2RAGE images","author":"Laines Medina","year":"2025"},{"key":"10.1016\/j.neurol.2026.04.003_bib0445","series-title":"Automatic spinal cord gray matter segmentation across multiple contrasts, magnetic fields, regions and pathologies","author":"Laines Medina","year":"2025"},{"key":"10.1016\/j.neurol.2026.04.003_bib0450","unstructured":"Laines Medina N, Gros C, Cohen-Adad J, Callot V, Le Troter A. 2D Multi-class model for gray and white matter segmentation of the cervical spinal cord at 7T\u20132021. https:\/\/doi.org\/arXiv:2110.06516."},{"key":"10.1016\/j.neurol.2026.04.003_bib0455","series-title":"Ultra-high field cervical spinal cord quantitative MRI: a 7T multi-center study of traveling spines","author":"Callot","year":"2025"},{"key":"10.1016\/j.neurol.2026.04.003_bib0460","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1093\/brain\/awy296","article-title":"Quantitative susceptibility mapping identifies inflammation in a subset of chronic multiple sclerosis lesions","volume":"142","author":"Kaunzner","year":"2019","journal-title":"Brain"},{"key":"10.1016\/j.neurol.2026.04.003_bib0465","doi-asserted-by":"crossref","first-page":"120460","DOI":"10.1016\/j.neuroimage.2023.120460","article-title":"Cervical spinal cord susceptibility-weighted MRI at 7T: application to multiple sclerosis","volume":"284","author":"Clarke","year":"2023","journal-title":"Neuroimage"},{"key":"10.1016\/j.neurol.2026.04.003_bib0470","series-title":"7T MRI shows enlarged anterior vein in the spinal cord of multiple sclerosis patients","author":"Witt","year":"2019"},{"key":"10.1016\/j.neurol.2026.04.003_bib0475","doi-asserted-by":"crossref","first-page":"120517","DOI":"10.1016\/j.neuroimage.2024.120517","article-title":"The dilated veins surrounding the cord in multiple sclerosis suggest elevated pressure and obstruction of the glymphatic system","volume":"286","author":"Bateman","year":"2024","journal-title":"NeuroImage"},{"key":"10.1016\/j.neurol.2026.04.003_bib0480","series-title":"Quantitative susceptibility mapping and phase imaging for the study of multiple sclerosis in the spinal cord at 7T","author":"Destruel","year":"2026"},{"key":"10.1016\/j.neurol.2026.04.003_bib0485","doi-asserted-by":"crossref","unstructured":"Robison R, Witt A, Combes A, O\u2019Grady K, Prock L, Houston D, et al. In pursuit of the central vein sign in multiple sclerosis in the cervical spinal cord at 7T. Proceedings of the ISMRM meeting, London, England, UK: n.d., p.\u00a00198. https:\/\/doi.org\/10.58530\/2022\/0198.","DOI":"10.58530\/2022\/0198"},{"key":"10.1016\/j.neurol.2026.04.003_bib0490","series-title":"Quantitative susceptibility mapping of the cervical spinal cord at 7 Tesla","author":"\u00d8fstaas","year":"2025"},{"key":"10.1016\/j.neurol.2026.04.003_bib0495","article-title":"Topographical variation of iron-rimmed lesions in the multiple sclerosis brain and spinal cord: a neuropathological study","author":"Pisa","year":"2025","journal-title":"Ann Neurol"},{"key":"10.1016\/j.neurol.2026.04.003_bib0500","series-title":"Quantitative magnetization transfer imaging of human cervical spinal cord at 7 Tesla","author":"Dortch","year":"2012"},{"key":"10.1016\/j.neurol.2026.04.003_bib0505","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1002\/mrm.27087","article-title":"Feasibility of single-shot multi-level multi-angle diffusion tensor imaging of the human cervical spinal cord at 7T","volume":"80","author":"Massire","year":"2018","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0510","series-title":"High-resolution multiparametric quantitative MRI of the cervical spinal cord at 7T: preliminary results at the early stage of multiple sclerosis","author":"Massire","year":"2019"},{"key":"10.1016\/j.neurol.2026.04.003_bib0515","series-title":"The good, the bad and the ugly: a retrospective study of image quality in human cervical spinal cord MRI at 7T","author":"Frebourg","year":"2021"},{"key":"10.1016\/j.neurol.2026.04.003_bib0520","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1002\/ana.26194","article-title":"7T MRI differentiates remyelinated from demyelinated multiple sclerosis lesions","volume":"90","author":"Kolb","year":"2021","journal-title":"Ann Neurol"},{"key":"10.1016\/j.neurol.2026.04.003_bib0525","doi-asserted-by":"crossref","first-page":"e210259","DOI":"10.1212\/WNL.0000000000210259","article-title":"Neurodegeneration and demyelination in the multiple sclerosis spinal cord: clinical, pathological, and 7T MRI perspectives","volume":"104","author":"Mahajan","year":"2025","journal-title":"Neurology"},{"key":"10.1016\/j.neurol.2026.04.003_bib0530","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.neuroimage.2017.11.031","article-title":"Spatiotemporal characterization of breathing-induced B0 field fluctuations in the cervical spinal cord at 7T","volume":"167","author":"Vannesjo","year":"2018","journal-title":"Neuroimage"},{"key":"10.1016\/j.neurol.2026.04.003_bib0535","doi-asserted-by":"crossref","first-page":"e02812","DOI":"10.7554\/eLife.02812","article-title":"Resting state functional connectivity in the human spinal cord","volume":"3","author":"Barry","year":"2014","journal-title":"Elife"},{"key":"10.1016\/j.neurol.2026.04.003_bib0540","author":"Horn","year":"2025","journal-title":"Ultra-high-field fMRI reveals layer-specific responses in the human spinal cord"},{"key":"10.1016\/j.neurol.2026.04.003_bib0545","doi-asserted-by":"crossref","first-page":"1650","DOI":"10.1093\/brain\/awy083","article-title":"Multiple sclerosis lesions affect intrinsic functional connectivity of the spinal cord","volume":"141","author":"Conrad","year":"2018","journal-title":"Brain"},{"key":"10.1016\/j.neurol.2026.04.003_bib0550","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1002\/nbm.3541","article-title":"(1) H MRS in the human spinal cord at 7\u00a0T using a dielectric waveguide transmitter, RF shimming and a high density receive array","volume":"29","author":"Henning","year":"2016","journal-title":"NMR Biomed"},{"key":"10.1016\/j.neurol.2026.04.003_bib0555","doi-asserted-by":"crossref","first-page":"2600","DOI":"10.1002\/mrm.29182","article-title":"Respiratory-triggered quantitative MR spectroscopy of the human cervical spinal cord at 7T","volume":"87","author":"Roussel","year":"2022","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0560","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1002\/nbm.3581","article-title":"Chemical exchange saturation transfer of the cervical spinal cord at 7T","volume":"29","author":"Dula","year":"2016","journal-title":"NMR Biomed"},{"key":"10.1016\/j.neurol.2026.04.003_bib0565","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.neuroimage.2013.03.072","article-title":"Imaging of glutamate in the spinal cord using GluCEST","volume":"77","author":"Kogan","year":"2013","journal-title":"Neuroimage"},{"key":"10.1016\/j.neurol.2026.04.003_bib0570","first-page":"1539","article-title":"Dynamic susceptibility contrast perfusion MR Imaging of multiple sclerosis lesions: characterizing hemodynamic impairment and inflammatory activity","volume":"26","author":"Ge","year":"2005","journal-title":"Am J Neuroradiol"},{"key":"10.1016\/j.neurol.2026.04.003_bib0575","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1002\/mrm.28559","article-title":"Feasibility of human spinal cord perfusion mapping using dynamic susceptibility contrast imaging at 7T: Preliminary results and identified guidelines","volume":"85","author":"L\u00e9vy","year":"2021","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0580","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1002\/mrm.28195","article-title":"Intravoxel Incoherent Motion at 7 Tesla to quantify human spinal cord perfusion: limitations and promises","volume":"84","author":"L\u00e9vy","year":"2020","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0585","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.neuroimage.2017.07.003","article-title":"Spinal cord MRI at 7T","volume":"168","author":"Barry","year":"2018","journal-title":"Neuroimage"},{"key":"10.1016\/j.neurol.2026.04.003_bib0590","series-title":"Ultra-high field spinal cord MRI. Advances in magnetic resonance technology and applications, vol. 10","author":"Callot","year":"2023"},{"key":"10.1016\/j.neurol.2026.04.003_bib0595","doi-asserted-by":"crossref","first-page":"e5002","DOI":"10.1002\/nbm.5002","article-title":"An 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7\u00a0Tesla","volume":"36","author":"Lopez-Rios","year":"2023","journal-title":"NMR Biomed"},{"key":"10.1016\/j.neurol.2026.04.003_bib0600","series-title":"Performance characterization of three coils for whole brain and\/or cervical spinal cord MRI at 7T","author":"Rangaprakash","year":"2022"},{"key":"10.1016\/j.neurol.2026.04.003_bib0605","series-title":"A self-decoupled 20\/32-channel Tx\/Rx array for simultaneous brain and spinal cord MRI at 7T","author":"Chai","year":"2024"},{"key":"10.1016\/j.neurol.2026.04.003_bib0610","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1002\/mrm.30551","article-title":"Multi-center benchmarking of cervical spinal cord RF coils for 7\u00a0T MRI: a traveling spines study","volume":"94","author":"Alonso-Ortiz","year":"2025","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0615","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1002\/mrm.29708","article-title":"Optimized interferometric encoding of presaturated TurboFLASH B1 mapping for parallel transmission MRI at 7\u00a0T: preliminary application for quantitative T1 mapping in the spinal cord","volume":"90","author":"Destruel","year":"2023","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0620","first-page":"2392","article-title":"RF shimming in the cervical spinal cord at 7T","volume":"92","author":"Papp","year":"2024","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0625","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1002\/mrm.30137","article-title":"Calibration-free parallel transmission of the cervical, thoracic, and lumbar spinal cord at 7T","volume":"92","author":"Aigner","year":"2024","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0630","doi-asserted-by":"crossref","DOI":"10.1002\/mrm.27664","article-title":"A method for correcting breathing-induced field fluctuations in T2*-weighted spinal cord imaging using a respiratory trace","volume":"81","author":"Vannesjo","year":"2019","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0635","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1002\/mrm.30475","article-title":"Optimized navigator-based correction of breathing-induced B0 field fluctuations in multi-echo gradient-echo imaging of the spinal cord","volume":"94","author":"Beghini","year":"2025","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0640","doi-asserted-by":"crossref","first-page":"8777","DOI":"10.1038\/s41598-023-35853-7","article-title":"Feasibility of spinal cord imaging at 7T using rosette trajectory with magnetization transfer preparation and compressed sensing","volume":"13","author":"Mahmud","year":"2023","journal-title":"Sci Rep"},{"key":"10.1016\/j.neurol.2026.04.003_bib0645","series-title":"Spatial specificity of BOLD signal in the spinal cord at 7T using a noxious thermal stimulus","author":"Seifert","year":"2020"},{"key":"10.1016\/j.neurol.2026.04.003_bib0650","series-title":"Repeatability and reproducibility of ultra high-field cervical spinal cord quantitative MRI: a dual-center study at 7T","author":"Seif","year":"2024"},{"key":"10.1016\/j.neurol.2026.04.003_bib0655","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1002\/mrm.24911","article-title":"Nineteen-channel receive array and four-channel transmit array coil for cervical spinal cord imaging at 7T: RF Coil for Spinal Cord MRI at 7T","volume":"72","author":"Zhao","year":"2014","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.neurol.2026.04.003_bib0660","series-title":"AMU7T: a 3D qT1 and T2*w high-resolution in vivo template with refined white and gray matter parcellation dedicated to 7T spinal cord MR analyses","author":"Le Troter","year":"2023"},{"key":"10.1016\/j.neurol.2026.04.003_bib0665","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1016\/j.neuroimage.2016.10.009","article-title":"SCT: Spinal Cord Toolbox, an open-source software for processing spinal cord MRI data","volume":"145","author":"De Leener","year":"2017","journal-title":"Neuroimage"},{"key":"10.1016\/j.neurol.2026.04.003_bib0670","series-title":"Spinal cord MS lesion detection at 7T: Added value of MP2RAGE imaging and requirement for automatic lesion segmentation","author":"Laines Medina","year":"2023"}],"container-title":["Revue Neurologique"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0035378726005096?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0035378726005096?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T13:15:05Z","timestamp":1792674905000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0035378726005096"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":67,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["S0035378726005096"],"URL":"https:\/\/doi.org\/10.1016\/j.neurol.2026.04.003","relation":{},"ISSN":["0035-3787"],"issn-type":[{"value":"0035-3787","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"7T magnetic resonance imaging of the human spinal cord in multiple sclerosis: Advances, insights and unmet needs","name":"articletitle","label":"Article Title"},{"value":"Revue Neurologique","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.neurol.2026.04.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Masson SAS.","name":"copyright","label":"Copyright"}]}}