{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T04:19:47Z","timestamp":1764562787312,"version":"3.46.0"},"reference-count":21,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.es","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Archivos de la Sociedad Espa\u00f1ola de Oftalmolog\u00eda (English Edition)"],"published-print":{"date-parts":[[2025,12]]},"DOI":"10.1016\/j.oftale.2025.10.009","type":"journal-article","created":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T00:47:14Z","timestamp":1761007634000},"page":"775-780","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Analysis of ocular biometric characteristics in a Mediterranean population"],"prefix":"10.1016","volume":"100","author":[{"given":"M.","family":"Martinez-de-la-Casa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Matilla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Garcia-Bella","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L.","family":"Morales","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Burgos-Blasco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"7","key":"10.1016\/j.oftale.2025.10.009_bib0005","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1136\/bjo.2009.163899","article-title":"Refractive error, axial length and anterior chamber depth of the eye in British adults: the EPIC-Norfolk Eye Study","volume":"94","author":"Foster","year":"2010","journal-title":"Br J Ophthalmol."},{"issue":"2","key":"10.1016\/j.oftale.2025.10.009_bib0010","first-page":"102","article-title":"Refractive error and ocular biometry in children and adults: a population study","volume":"25","author":"Mallen","year":"2005","journal-title":"Ophthalmic Physiol Opt."},{"issue":"3","key":"10.1016\/j.oftale.2025.10.009_bib0015","first-page":"523","article-title":"Refractive errors in an older population: the Blue Mountains Eye Study","volume":"106","author":"Attebo","year":"1999","journal-title":"Ophthalmology."},{"key":"10.1016\/j.oftale.2025.10.009_bib0020","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1111\/opo.12728","article-title":"Age-related axial length changes in adults: a review","volume":"40","author":"Rozema","year":"2020","journal-title":"Ophthalmic Physiol Opt"},{"issue":"4","key":"10.1016\/j.oftale.2025.10.009_bib0025","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1001\/archopht.123.4.527","article-title":"Anterior chamber depth and the risk of primary angle closure in 2 East Asian populations","volume":"123","author":"Aung","year":"2005","journal-title":"Arch Ophthalmol."},{"issue":"3","key":"10.1016\/j.oftale.2025.10.009_bib0030","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/j.ophtha.2010.07.025","article-title":"Lens vault, thickness, and position in Chinese subjects with angle closure","volume":"118","author":"Nongpiur","year":"2011","journal-title":"Ophthalmology."},{"key":"10.1016\/j.oftale.2025.10.009_bib0035","doi-asserted-by":"crossref","first-page":"421","DOI":"10.3341\/kjo.2013.27.6.421","article-title":"The correlation between angle kappa and ocular biometry in Koreans","volume":"27","author":"Choi","year":"2013","journal-title":"Korean J Ophthalmol"},{"issue":"3","key":"10.1016\/j.oftale.2025.10.009_bib0040","first-page":"447","article-title":"Laser peripheral iridotomy in primary angle-closure suspects: biometric and gonioscopic outcomes","volume":"113","author":"He","year":"2006","journal-title":"Ophthalmology."},{"issue":"6","key":"10.1016\/j.oftale.2025.10.009_bib0045","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1016\/S0886-3350(13)80339-2","article-title":"An improved universal theoretical formula for intraocular lens power prediction","volume":"19","author":"Barrett","year":"1993","journal-title":"J Cataract Refract Surg."},{"issue":"1","key":"10.1016\/j.oftale.2025.10.009_bib0050","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1186\/s12886-021-01932-4","article-title":"Distribution of ocular biometric parameters and optimal model of anterior chamber depth regression in 28,709 adult cataract patients in China using swept-source optical biometry","volume":"21","author":"Lei","year":"2021","journal-title":"BMC Ophthalmol."},{"key":"10.1016\/j.oftale.2025.10.009_bib0055","doi-asserted-by":"crossref","first-page":"1701","DOI":"10.1016\/j.jcrs.2007.05.040","article-title":"Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopia","volume":"33","author":"Hashemi","year":"2007","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"10.1016\/j.oftale.2025.10.009_bib0060","first-page":"429","article-title":"Evaluation of intraocular lens power prediction methods using a large cataract surgery database","volume":"44","author":"Melles","year":"2018","journal-title":"J Cataract Refract Surg."},{"key":"10.1016\/j.oftale.2025.10.009_bib0065","doi-asserted-by":"crossref","DOI":"10.1016\/j.exer.2021.108653","article-title":"Relationship of the cornea and globe dimensions to the changes in adult human crystalline lens diameter, thickness and power with age","volume":"209","author":"Mohamed","year":"2021","journal-title":"Exp Eye Res."},{"issue":"8","key":"10.1016\/j.oftale.2025.10.009_bib0070","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1016\/j.ophtha.2004.01.025","article-title":"Prevalence of open-angle glaucoma and ocular hypertension in Latinos: the Los Angeles Latino Eye Study","volume":"111","author":"Varma","year":"2004","journal-title":"Ophthalmology."},{"issue":"3","key":"10.1016\/j.oftale.2025.10.009_bib0075","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1097\/01.ico.0000148312.01805.53","article-title":"White-to-white corneal diameter: normal values in healthy humans obtained with the Orbscan II topography system","volume":"24","author":"R\u00fcfer","year":"2005","journal-title":"Cornea."},{"key":"10.1016\/j.oftale.2025.10.009_bib0080","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.jcrs.2003.06.004","article-title":"Comparison of manual and automated methods to determine horizontal corneal diameter","volume":"30","author":"Baumeister","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.oftale.2025.10.009_bib0085","doi-asserted-by":"crossref","first-page":"53","DOI":"10.5301\/ejo.5000332","article-title":"Effect of pharmacologic pupil dilation on OLCR optical biometry measurements for IOL predictions","volume":"24","author":"Arriola-Villalobos","year":"2014","journal-title":"Eur J Ophthalmol"},{"issue":"1","key":"10.1016\/j.oftale.2025.10.009_bib0090","doi-asserted-by":"crossref","first-page":"74","DOI":"10.18240\/ijo.2025.01.08","article-title":"Risk factors for biometry prediction error by Barrett Universal II intraocular lens formula in Chinese patients","volume":"18","author":"Chen","year":"2025","journal-title":"Int J Ophthalmol."},{"issue":"1","key":"10.1016\/j.oftale.2025.10.009_bib0095","first-page":"324","article-title":"Ocular axial length and its associations in a rural population in North India: the Central India Eye and Medical Study","volume":"56","author":"Nangia","year":"2015","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"10.1016\/j.oftale.2025.10.009_bib0100","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.ajo.2022.09.022","article-title":"Optical biometry and IOL calculation in a commercially available optical coherence tomography device and comparison with pentacam AXL","volume":"246","author":"Kanclerz","year":"2023","journal-title":"Am J Ophthalmol."},{"issue":"2","key":"10.1016\/j.oftale.2025.10.009_bib0105","first-page":"183","article-title":"Ocular biometric values and prevalence of corneal astigmatism in patients candidate for cataract surgery","volume":"49","author":"Hashemian","year":"2023","journal-title":"J Cataract Refract Surg."}],"container-title":["Archivos de la Sociedad Espa\u00f1ola de Oftalmolog\u00eda (English Edition)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2173579425002002?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2173579425002002?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T03:48:42Z","timestamp":1764560922000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2173579425002002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":21,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["S2173579425002002"],"URL":"https:\/\/doi.org\/10.1016\/j.oftale.2025.10.009","relation":{},"ISSN":["2173-5794"],"issn-type":[{"type":"print","value":"2173-5794"}],"subject":[],"published":{"date-parts":[[2025,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Analysis of ocular biometric characteristics in a Mediterranean population","name":"articletitle","label":"Article Title"},{"value":"Archivos de la Sociedad Espa\u00f1ola de Oftalmolog\u00eda (English Edition)","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.oftale.2025.10.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"https:\/\/doi.org\/10.1016\/j.oftal.2025.07.010","name":"associatedlink","label":"CrossRef DOI link to the associated document"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Sociedad Espa\u00f1ola de Oftalmolog\u00eda. Published by Elsevier Espa\u00f1a, S.L.U. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}