{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T03:46:07Z","timestamp":1775015167053,"version":"3.50.1"},"reference-count":26,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.es","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Archivos de la Sociedad Espa\u00f1ola de Oftalmolog\u00eda (English Edition)"],"published-print":{"date-parts":[[2026,4]]},"DOI":"10.1016\/j.oftale.2026.502519","type":"journal-article","created":{"date-parts":[[2026,2,22]],"date-time":"2026-02-22T15:22:16Z","timestamp":1771773736000},"page":"502519","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Static cyclotorsion registration during excimer laser surgery: reliability and repeatability"],"prefix":"10.1016","volume":"101","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4567-348X","authenticated-orcid":false,"given":"I.","family":"Almor\u00edn-Fern\u00e1ndez-Vigo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9220-8081","authenticated-orcid":false,"given":"I.","family":"S\u00e1nchez-Guill\u00e9n","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8745-3464","authenticated-orcid":false,"given":"J.I.","family":"Fern\u00e1ndez-Vigo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.B.","family":"Mart\u00edn-Polo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6952-4521","authenticated-orcid":false,"given":"L.","family":"De-Pablo-G\u00f3mez-de-Lia\u00f1o","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"G\u00f3mez-de-Lia\u00f1o","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Macarro-Merino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.A.","family":"Fern\u00e1ndez-Vigo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"8","key":"10.1016\/j.oftale.2026.502519_bib0005","doi-asserted-by":"crossref","first-page":"1752","DOI":"10.1016\/j.jcrs.2015.07.017","article-title":"Effects of torsional movements in refractive procedures","volume":"41","author":"Mosquera","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"10.1016\/j.oftale.2026.502519_bib0010","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1136\/bjophthalmol-2014-304975","article-title":"Cyclotorsional and non-cyclotorsional components of eye rotation observed from sitting to supine position","volume":"99","author":"Prickett","year":"2015","journal-title":"Br J Ophthalmol"},{"issue":"12","key":"10.1016\/j.oftale.2026.502519_bib0015","doi-asserted-by":"crossref","first-page":"2032","DOI":"10.1109\/TBME.2005.857674","article-title":"Iris-based cyclotorsional image alignment method for wavefront registration","volume":"52","author":"Chernyak","year":"2005","journal-title":"IEEE Trans Biomed Eng"},{"issue":"11","key":"10.1016\/j.oftale.2026.502519_bib0020","first-page":"985","article-title":"Outcomes of myopic LASIK with and without NIDEK active torsion error correction","volume":"25","author":"Venter","year":"2009","journal-title":"J Refract Surg Thorofare NJ 1995"},{"issue":"9","key":"10.1016\/j.oftale.2026.502519_bib0025","article-title":"Active cyclotorsion error correction during LASIK for myopia and myopic astigmatism with the NIDEK EC-5000 CX III laser","volume":"23","author":"Bharti","year":"2007","journal-title":"J Refract Surg"},{"issue":"10","key":"10.1016\/j.oftale.2026.502519_bib0030","doi-asserted-by":"crossref","first-page":"1720","DOI":"10.1016\/j.jcrs.2008.06.027","article-title":"Cyclotorsion during laser in situ keratomileusis","volume":"34","author":"Chang","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"10.1016\/j.oftale.2026.502519_bib0035","doi-asserted-by":"crossref","first-page":"106","DOI":"10.3928\/1081597X-20171128-02","article-title":"Factors influencing cyclotorsion during photorefractive keratectomy","volume":"34","author":"Alipour","year":"2018","journal-title":"J Refract Surg"},{"issue":"5","key":"10.1016\/j.oftale.2026.502519_bib0040","doi-asserted-by":"crossref","first-page":"458","DOI":"10.3341\/kjo.2019.0042","article-title":"Effects of cyclotorsion orientation and magnitude in eyes with compound myopic astigmatism on the compensation capacity of WaveLight EX500 photorefractive keratectomy","volume":"33","author":"Ozulken","year":"2019","journal-title":"Korean J Ophthalmol KJO"},{"issue":"2","key":"10.1016\/j.oftale.2026.502519_bib0045","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.ajo.2009.08.021","article-title":"Predictive factor analysis for successful performance of iris recognition-assisted dynamic rotational eye tracking during laser in situ keratomileusis","volume":"149","author":"Prakash","year":"2010","journal-title":"Am J Ophthalmol"},{"issue":"9","key":"10.1016\/j.oftale.2026.502519_bib0050","doi-asserted-by":"crossref","first-page":"1955","DOI":"10.1007\/s10792-018-1028-6","article-title":"Normative Pentacam anterior and posterior corneal elevation measurements: effects of age, sex, axial length and white-to-white","volume":"39","author":"Almor\u00edn-Fern\u00e1ndez-Vigo","year":"2019","journal-title":"Int Ophthalmol"},{"key":"10.1016\/j.oftale.2026.502519_bib0055","unstructured":"Alcon. Manual de usuario ALLEGRO Topolyzer VARIO 1028\/1029 es \/ Rev. 08 \/ 26-04-2018 C\u00f3digo: 6671 2001. Published online April 26, 2018."},{"key":"10.1016\/j.oftale.2026.502519_bib0060","unstructured":"Alcon. Manual de usuario WaveLight\u00ae EX500 1016 es \/ Rev.10 \/ 07-03-2022 C\u00f3digo: 6672 2001. Published online March 7, 2022."},{"issue":"9","key":"10.1016\/j.oftale.2026.502519_bib0065","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1097\/ICO.0b013e318207eac2","article-title":"Three-month clinical outcomes with static and dynamic cyclotorsion correction using the SCHWIND AMARIS","volume":"30","author":"Arba-Mosquera","year":"2011","journal-title":"Cornea"},{"key":"10.1016\/j.oftale.2026.502519_bib0070","first-page":"1","article-title":"Image-guided marking versus manual marking in phacoemulsification with Toric Intraocular Lens (IOL) implantation: a systematic review and meta-analysis of randomized clinical trials","author":"Yao","year":"2023","journal-title":"Semin Ophthalmol"},{"issue":"2","key":"10.1016\/j.oftale.2026.502519_bib0075","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0171851","article-title":"Comparative evaluation of visual outcomes and corneal asphericity after laser-assisted in situ keratomileusis with the six-dimension Amaris excimer laser system. Malik RA, ed","volume":"12","author":"Piao","year":"2017","journal-title":"PLoS One"},{"issue":"4","key":"10.1016\/j.oftale.2026.502519_bib0080","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.jcrs.2007.11.030","article-title":"Ocular cyclotorsion according to body position and flap creation before laser in situ keratomileusis","volume":"34","author":"Kim","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"10.1016\/j.oftale.2026.502519_bib0085","doi-asserted-by":"crossref","first-page":"159","DOI":"10.5935\/0004-2749.20140041","article-title":"Static cyclotorsion measurements using the Schwind Amaris laser","volume":"77","author":"Fahd","year":"2014","journal-title":"Arq Bras Oftalmol"},{"issue":"10","key":"10.1016\/j.oftale.2026.502519_bib0090","doi-asserted-by":"crossref","DOI":"10.1523\/ENEURO.0005-23.2023","article-title":"Pupil size is sensitive to low-level stimulus features, independent of arousal-related modulation","volume":"10","author":"Kim","year":"2023","journal-title":"eNeuro"},{"key":"10.1016\/j.oftale.2026.502519_bib0095","doi-asserted-by":"crossref","DOI":"10.3389\/fcell.2023.1174122","article-title":"Using a smartphone app in the measurement of posture-related pupil center shift on centration during corneal refractive surgery","volume":"11","author":"Cheng","year":"2023","journal-title":"Front Cell Dev Biol"},{"issue":"4","key":"10.1016\/j.oftale.2026.502519_bib0100","doi-asserted-by":"crossref","first-page":"371","DOI":"10.3928\/1081-597X-20040701-11","article-title":"Limitations of pupil tracking in refractive surgery: systematic error in determination of corneal locations","volume":"20","author":"Bueeler","year":"2004","journal-title":"J Refract Surg"},{"issue":"5","key":"10.1016\/j.oftale.2026.502519_bib0105","doi-asserted-by":"crossref","first-page":"463","DOI":"10.3928\/1081-597X-20050901-07","article-title":"From wavefront device to laser: an alignment method for complete registration of the ablation to the cornea","volume":"21","author":"Chernyak","year":"2005","journal-title":"J Refract Surg"},{"key":"10.1016\/j.oftale.2026.502519_bib0110","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.compbiomed.2017.05.030","article-title":"Cyclotorsion measurement using scleral blood vessels","volume":"87","author":"Kaya","year":"2017","journal-title":"Comput Biol Med"},{"issue":"5","key":"10.1016\/j.oftale.2026.502519_bib0115","doi-asserted-by":"crossref","first-page":"353","DOI":"10.3928\/1081597X-20120124-03","article-title":"Intraoperative cyclorotation and pupil centroid shift during LASIK and PRK","volume":"28","author":"Narv\u00e1ez","year":"2012","journal-title":"J Refract Surg"},{"issue":"10","key":"10.1016\/j.oftale.2026.502519_bib0120","doi-asserted-by":"crossref","first-page":"1718","DOI":"10.1016\/j.jcrs.2010.05.019","article-title":"Detection of static cyclotorsion and compensation for dynamic cyclotorsion in laser in situ keratomileusis","volume":"36","author":"Febbraro","year":"2010","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"10.1016\/j.oftale.2026.502519_bib0125","doi-asserted-by":"crossref","first-page":"582","DOI":"10.3928\/1081597X-20110120-02","article-title":"Use of a six-dimensional eye-tracker in corneal laser refractive surgery with the SCHWIND AMARIS TotalTech laser","volume":"27","author":"Arba-Mosquera","year":"2011","journal-title":"J Refract Surg"},{"issue":"5","key":"10.1016\/j.oftale.2026.502519_bib0130","first-page":"358","article-title":"Effect of limbal marking prior to laser ablation on the magnitude of cyclotorsional error","volume":"28","author":"Chen","year":"2012","journal-title":"J Refract Surg Thorofare NJ 1995"}],"container-title":["Archivos de la Sociedad Espa\u00f1ola de Oftalmolog\u00eda (English Edition)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2173579426000265?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2173579426000265?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T02:25:11Z","timestamp":1775010311000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2173579426000265"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,4]]}},"alternative-id":["S2173579426000265"],"URL":"https:\/\/doi.org\/10.1016\/j.oftale.2026.502519","relation":{},"ISSN":["2173-5794"],"issn-type":[{"value":"2173-5794","type":"print"}],"subject":[],"published":{"date-parts":[[2026,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Static cyclotorsion registration during excimer laser surgery: reliability and repeatability","name":"articletitle","label":"Article Title"},{"value":"Archivos de la Sociedad Espa\u00f1ola de Oftalmolog\u00eda (English Edition)","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.oftale.2026.502519","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"https:\/\/doi.org\/10.1016\/j.oftal.2026.502519","name":"associatedlink","label":"CrossRef DOI link to the associated document"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Sociedad Espa\u00f1ola de Oftalmolog\u00eda. Published by Elsevier Espa\u00f1a, S.L.U. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"502519"}}