{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T20:07:33Z","timestamp":1762632453196,"version":"build-2065373602"},"reference-count":14,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T00:00:00Z","timestamp":1740787200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T00:00:00Z","timestamp":1740787200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100002977","name":"Dalhousie University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002977","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmology Glaucoma"],"published-print":{"date-parts":[[2025,3]]},"DOI":"10.1016\/j.ogla.2024.10.008","type":"journal-article","created":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T19:57:25Z","timestamp":1730491045000},"page":"152-156","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Comparative Study of the Handheld IC200 and Slit Lamp-mounted ST500 Rebound Tonometers with Goldmann Applanation Tonometry"],"prefix":"10.1016","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3935-9283","authenticated-orcid":false,"given":"Ryo","family":"Tomita","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Glen P.","family":"Sharpe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Devin","family":"Betsch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9912-2582","authenticated-orcid":false,"given":"Rodolfo","family":"Bonatti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Balwantray C.","family":"Chauhan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ogla.2024.10.008_bib1","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/S0002-9394(98)00272-4","article-title":"The effectiveness of intraocular pressure reduction in the treatment of normal-tension glaucoma. Collaborative Normal-Tension Glaucoma Study Group","volume":"126","year":"1998","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ogla.2024.10.008_bib2","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/S0002-9394(00)00538-9","article-title":"The relationship between control of intraocular pressure and visual field deterioration.The AGIS Investigators","volume":"130","year":"2000","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ogla.2024.10.008_bib3","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/S0161-6420(96)30741-0","article-title":"Standardizing the measurement of intraocular pressure for clinical research. Guidelines from the Eye Care Technology Forum","volume":"103","author":"Kass","year":"1996","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ogla.2024.10.008_bib4","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/IJG.0b013e318133fb32","article-title":"Clinical comparison of the Icare tonometer and Goldmann applanation tonometry","volume":"17","author":"Pakrou","year":"2008","journal-title":"J\u00a0Glaucoma"},{"key":"10.1016\/j.ogla.2024.10.008_bib5","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/j.jcjo.2022.06.002","article-title":"Comparison of intraocular pressure measured by iCare tonometers and Goldmann applanation tonometer","volume":"58","author":"Sachdeva","year":"2023","journal-title":"Can J Ophthalmol"},{"key":"10.1016\/j.ogla.2024.10.008_bib6","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1136\/bjo.85.7.792","article-title":"Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension","volume":"85","author":"Ventura","year":"2001","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ogla.2024.10.008_bib7","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1111\/j.1755-3768.1993.tb04988.x","article-title":"Accuracy of Goldmann tonometry in clinical practice","volume":"71","author":"Sudesh","year":"1993","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.ogla.2024.10.008_bib8","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/IJG.0b013e31802fc6bc","article-title":"Reproducibility and tolerability of the ICare rebound tonometer in school children","volume":"16","author":"Sahin","year":"2007","journal-title":"J\u00a0Glaucoma"},{"key":"10.1016\/j.ogla.2024.10.008_bib9","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.3892\/etm.2017.4164","article-title":"Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer","volume":"13","author":"Gao","year":"2017","journal-title":"Exp Ther Med"},{"key":"10.1016\/j.ogla.2024.10.008_bib10","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/s40662-021-00249-z","article-title":"Evaluation of rebound tonometer iCare IC200 as compared with IcarePRO and Goldmann applanation tonometer in patients with glaucoma","volume":"8","author":"Nakakura","year":"2021","journal-title":"Eye Vis (Lond)"},{"key":"10.1016\/j.ogla.2024.10.008_bib11","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.ogla.2020.08.004","article-title":"Agreement of intraocular pressure measurement of Icare ic200 with Goldmann applanation tonometer in adult eyes with normal cornea","volume":"4","author":"Badakere","year":"2021","journal-title":"Ophthalmol Glaucoma"},{"key":"10.1016\/j.ogla.2024.10.008_bib12","doi-asserted-by":"crossref","first-page":"1572","DOI":"10.1136\/bjo.2005.075580","article-title":"The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry","volume":"89","author":"Kotecha","year":"2005","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ogla.2024.10.008_bib13","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0039-6257(93)90053-A","article-title":"Sources of error with use of Goldmann-type tonometers","volume":"38","author":"Whitacre","year":"1993","journal-title":"Surv Ophthalmol"},{"key":"10.1016\/j.ogla.2024.10.008_bib15","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1016\/j.ophtha.2009.09.020","article-title":"Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers","volume":"117","author":"Kotecha","year":"2010","journal-title":"Ophthalmology"}],"container-title":["Ophthalmology Glaucoma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2589419624001868?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2589419624001868?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T20:04:31Z","timestamp":1762632271000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2589419624001868"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3]]},"references-count":14,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,3]]}},"alternative-id":["S2589419624001868"],"URL":"https:\/\/doi.org\/10.1016\/j.ogla.2024.10.008","relation":{},"ISSN":["2589-4196"],"issn-type":[{"type":"print","value":"2589-4196"}],"subject":[],"published":{"date-parts":[[2025,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A Comparative Study of the Handheld IC200 and Slit Lamp-mounted ST500 Rebound Tonometers with Goldmann Applanation Tonometry","name":"articletitle","label":"Article Title"},{"value":"Ophthalmology Glaucoma","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ogla.2024.10.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 by the American Academy of Ophthalmology","name":"copyright","label":"Copyright"}]}}