{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T16:43:11Z","timestamp":1793724191408,"version":"4.6.1"},"reference-count":26,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001079","name":"AuDA Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001079","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmology Glaucoma"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1016\/j.ogla.2025.10.008","type":"journal-article","created":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T12:00:42Z","timestamp":1763640042000},"page":"185-192","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"title":["Melbourne Rapid Fields Online Perimeter Home Visual Field Study for Glaucoma"],"prefix":"10.1016","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0522-3046","authenticated-orcid":false,"given":"George Y.X.","family":"Kong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed","family":"Dirani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joyce","family":"Tiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1056-4470","authenticated-orcid":false,"given":"Selwyn M.","family":"Prea","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5144-3694","authenticated-orcid":false,"given":"Phillip","family":"Bedggood","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5920-4604","authenticated-orcid":false,"given":"Algis J.","family":"Vingrys","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ogla.2025.10.008_bib1","doi-asserted-by":"crossref","first-page":"1788","DOI":"10.1016\/S0140-6736(23)01289-8","article-title":"Glaucoma: now and beyond","volume":"402","author":"Jayaram","year":"2023","journal-title":"Lancet"},{"key":"10.1016\/j.ogla.2025.10.008_bib2","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1136\/bjo.2007.135012","article-title":"Practical recommendations for measuring rates of visual field change in glaucoma","volume":"92","author":"Chauhan","year":"2008","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ogla.2025.10.008_bib3","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1136\/bjophthalmol-2012-302903","article-title":"Are practical recommendations practiced? A national multi-centre cross-sectional study on frequency of visual field testing in glaucoma","volume":"97","author":"Fung","year":"2013","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ogla.2025.10.008_bib4","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1007\/s11606-009-0955-3","article-title":"Not perfect, but better: primary care providers\u2019 experiences with electronic referrals in a safety net health system","volume":"24","author":"Kim","year":"2009","journal-title":"J Gen Intern Med"},{"key":"10.1016\/j.ogla.2025.10.008_bib5","doi-asserted-by":"crossref","first-page":"1735","DOI":"10.1016\/j.ophtha.2017.06.028","article-title":"Can home monitoring allow earlier detection of rapid visual field progression in glaucoma?","volume":"124","author":"Anderson","year":"2017","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ogla.2025.10.008_bib6","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0161974","article-title":"Visual field testing with head-mounted perimeter \u2018imo\u2019","volume":"11","author":"Matsumoto","year":"2016","journal-title":"PLoS One"},{"key":"10.1016\/j.ogla.2025.10.008_bib7","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1167\/tvst.13.8.7","article-title":"Glaucoma home self-testing using VR visual fields and rebound tonometry versus in-clinic perimetry and Goldmann applanation tonometry: a pilot study","volume":"13","author":"Berneshawi","year":"2024","journal-title":"Transl Vis Sci Technol"},{"key":"10.1016\/j.ogla.2025.10.008_bib8","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1167\/tvst.5.6.2","article-title":"A comparison of perimetric results from a tablet perimeter and Humphrey field analyzer in glaucoma patients","volume":"5","author":"Kong","year":"2016","journal-title":"Transl Vis Sci Technol"},{"key":"10.1016\/j.ogla.2025.10.008_bib9","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.ogla.2021.09.002","article-title":"Glaucoma screening using an iPad-based visual field test in a West African population","volume":"5","author":"Prince","year":"2022","journal-title":"Ophthalmol Glaucoma"},{"key":"10.1016\/j.ogla.2025.10.008_bib10","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1167\/tvst.5.4.3","article-title":"Validation of a tablet as a tangent perimeter","volume":"5","author":"Vingrys","year":"2016","journal-title":"Transl Vis Sci Technol"},{"key":"10.1016\/j.ogla.2025.10.008_bib11","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.ajo.2020.08.039","article-title":"Glaucoma home monitoring using a tablet-based visual field test (eyecatcher): an assessment of accuracy and adherence over 6 months","volume":"223","author":"Jones","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ogla.2025.10.008_bib12","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1167\/tvst.7.5.32","article-title":"Home monitoring of retinal sensitivity on a tablet device in intermediate age-related macular degeneration","volume":"7","author":"Adams","year":"2018","journal-title":"Transl Vis Sci Technol"},{"key":"10.1016\/j.ogla.2025.10.008_bib13","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1016\/j.ajo.2020.10.023","article-title":"Uptake, persistence, and performance of weekly home monitoring of visual field in a large cohort of patients with glaucoma","volume":"223","author":"Prea","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ogla.2025.10.008_bib14","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1097\/OPX.0000000000001889","article-title":"Evaluation of the Melbourne rapid fields test procedure","volume":"99","author":"Harris","year":"2022","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ogla.2025.10.008_bib15","series-title":"Short-term reliability of home-based visual field assessment with Melbourne rapid dields (MRF) device-independent online perimetry for patients with Glaucoma","author":"Montesano","year":"2023"},{"key":"10.1016\/j.ogla.2025.10.008_bib16","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/j.ogla.2023.03.001","article-title":"Comparison of perimetric outcomes from a tablet perimeter, smart visual function analyzer, and Humphrey field analyzer","volume":"6","author":"Kang","year":"2023","journal-title":"Ophthalmol Glaucoma"},{"key":"10.1016\/j.ogla.2025.10.008_bib17","doi-asserted-by":"crossref","DOI":"10.3389\/fopht.2025.1485950","article-title":"Multi-centre comparison between device-independent web-browser perimetry (Melbourne Rapid Fields-web) and SITA-Faster for glaucoma","volume":"5","author":"Tiang","year":"2025","journal-title":"Front Ophthalmol"},{"key":"10.1016\/j.ogla.2025.10.008_bib18","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1097\/IJG.0000000000002059","article-title":"An objective and easy-to-use glaucoma functional severity staging system based on artificial intelligence","volume":"31","author":"Huang","year":"2022","journal-title":"J Glaucoma"},{"issue":"S1","key":"10.1016\/j.ogla.2025.10.008_bib19","doi-asserted-by":"crossref","first-page":"S29","DOI":"10.1038\/sj.eye.6702885","article-title":"Correlation of visual changes with disc morphology","volume":"21","author":"Garway-Heath","year":"2007","journal-title":"Eye"},{"key":"10.1016\/j.ogla.2025.10.008_bib20","series-title":"An Introduction to the Bootstrap","author":"Efron","year":"1994"},{"key":"10.1016\/j.ogla.2025.10.008_bib21","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.ajo.2018.03.009","article-title":"Six-month longitudinal comparison of a portable tablet perimeter with the Humphrey field analyzer","volume":"190","author":"Prea","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ogla.2025.10.008_bib22","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1097\/OPX.0b013e31818b9b40","article-title":"Is there evidence for continued learning over multiple years in perimetry?","volume":"85","author":"Gardiner","year":"2008","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ogla.2025.10.008_bib23","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.ajo.2019.08.013","article-title":"Clinical evaluation of Swedish interactive thresholding algorithm-faster compared with Swedish interactive thresholding algorithm-standard in normal subjects, glaucoma suspects, and patients with glaucoma","volume":"208","author":"Phu","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ogla.2025.10.008_bib24","doi-asserted-by":"crossref","first-page":"4317","DOI":"10.3390\/jcm11154317","article-title":"Test reliability and compliance to a twelve-month visual field telemedicine study in glaucoma patients","volume":"11","author":"Prea","year":"2022","journal-title":"J Clin Med"},{"key":"10.1016\/j.ogla.2025.10.008_bib25","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.ogla.2023.03.006","article-title":"Frontloading SITA-Faster can increase frequency and reliability of visual field testing at minimal time cost","volume":"6","author":"Tan","year":"2023","journal-title":"Ophthalmol Glaucoma"},{"key":"10.1016\/j.ogla.2025.10.008_bib26","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1111\/opo.13006","article-title":"Gaze tracker parameters have little association with visual field metrics of intrasession frontloaded SITA-Faster 24-2 visual field results","volume":"42","author":"Phu","year":"2022","journal-title":"Ophthalmic Physiol Opt"}],"container-title":["Ophthalmology Glaucoma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2589419625002406?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2589419625002406?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T23:39:14Z","timestamp":1773963554000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2589419625002406"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["S2589419625002406"],"URL":"https:\/\/doi.org\/10.1016\/j.ogla.2025.10.008","relation":{},"ISSN":["2589-4196"],"issn-type":[{"value":"2589-4196","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Melbourne Rapid Fields Online Perimeter Home Visual Field Study for Glaucoma","name":"articletitle","label":"Article Title"},{"value":"Ophthalmology Glaucoma","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ogla.2025.10.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 by the American Academy of Ophthalmology","name":"copyright","label":"Copyright"}]}}