{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T04:01:19Z","timestamp":1793505679834,"version":"4.5.0"},"reference-count":42,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,6,1]],"date-time":"2025-06-01T00:00:00Z","timestamp":1748736000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,6,1]],"date-time":"2025-06-01T00:00:00Z","timestamp":1748736000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T00:00:00Z","timestamp":1743206400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["hardware-x.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["HardwareX"],"published-print":{"date-parts":[[2025,6]]},"DOI":"10.1016\/j.ohx.2025.e00647","type":"journal-article","created":{"date-parts":[[2025,4,10]],"date-time":"2025-04-10T11:44:31Z","timestamp":1744285471000},"page":"e00647","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"special_numbering":"C","title":["Design and evaluation of a voltage-controlled current source for galvanic vestibular stimulation research"],"prefix":"10.1016","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8706-6269","authenticated-orcid":false,"given":"Zhi","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shieru","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatsuki","family":"Fushimi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoichi","family":"Ochiai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ohx.2025.e00647_b1","doi-asserted-by":"crossref","first-page":"117","DOI":"10.3389\/fneur.2012.00117","article-title":"What galvanic vestibular stimulation actually activates","volume":"3","author":"Curthoys","year":"2012","journal-title":"Front. Neurol."},{"key":"10.1016\/j.ohx.2025.e00647_b2","series-title":"Electrified Minds: Transcranial Direct Current Stimulation (tDCS) and Galvanic Vestibular Stimulation (GVS) as Methods of Non-Invasive Brain Stimulation in Neuropsychology\u2013A Review of Current Data and Future Implications","author":"Utz","year":"2010"},{"issue":"6","key":"10.1016\/j.ohx.2025.e00647_b3","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1152\/jn.1984.51.6.1236","article-title":"Relation between discharge regularity and responses to externally applied galvanic currents in vestibular nerve afferents of the squirrel monkey","volume":"51","author":"Goldberg","year":"1984","journal-title":"J. Neurophysiol."},{"key":"10.1016\/j.ohx.2025.e00647_b4","series-title":"Vestibular-Nerve Inputs to the Vestibulo-Ocular Reflex: a Functional- Ablation Study in the Squirrel Monkey","author":"Minor","year":"1991"},{"key":"10.1016\/j.ohx.2025.e00647_b5","doi-asserted-by":"crossref","first-page":"S202","DOI":"10.1016\/j.bjorl.2022.05.010","article-title":"Galvanic vestibular stimulation and its applications: a systematic review","volume":"88","author":"de \u00c1vila Pires","year":"2022","journal-title":"Braz. J. Otorhinolaryngol."},{"issue":"1","key":"10.1016\/j.ohx.2025.e00647_b6","doi-asserted-by":"crossref","DOI":"10.1038\/srep10168","article-title":"Four-pole galvanic vestibular stimulation causes body sway about three axes","volume":"5","author":"Aoyama","year":"2015","journal-title":"Sci. Rep."},{"issue":"3","key":"10.1016\/j.ohx.2025.e00647_b7","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1113\/jphysiol.2003.045971","article-title":"Effects of galvanic vestibular stimulation on human posture and perception while standing","volume":"551","author":"Wardman","year":"2003","journal-title":"J. Physiol."},{"key":"10.1016\/j.ohx.2025.e00647_b8","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/s11055-008-0029-8","article-title":"Effects of artificial feedback to the vestibular input on postural instability induced by asymmetric proprioceptive stimulation","volume":"38","author":"Orlov","year":"2008","journal-title":"Neurosci. Behav. Physiol."},{"issue":"9","key":"10.1016\/j.ohx.2025.e00647_b9","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1080\/00016480410015730","article-title":"Galvanic-induced body sway in vestibular Schwannoma patients: evidence for stimulation of the central vestibular system","volume":"124","author":"Balter","year":"2004","journal-title":"Acta Oto- Laryngol."},{"key":"10.1016\/j.ohx.2025.e00647_b10","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1007\/PL00007991","article-title":"Enhancing human balance control with galvanic vestibular stimulation","volume":"84","author":"Scinicariello","year":"2001","journal-title":"Biol. Cybernet."},{"key":"10.1016\/j.ohx.2025.e00647_b11","doi-asserted-by":"crossref","DOI":"10.3389\/fnhum.2020.591671","article-title":"The effects of stochastic galvanic vestibular stimulation on body sway and muscle activity","volume":"14","author":"Matsugi","year":"2020","journal-title":"Front. Hum. Neurosci."},{"issue":"1","key":"10.1016\/j.ohx.2025.e00647_b12","doi-asserted-by":"crossref","first-page":"37575","DOI":"10.1038\/srep37575","article-title":"Noisy galvanic vestibular stimulation induces a sustained improvement in body balance in elderly adults","volume":"6","author":"Fujimoto","year":"2016","journal-title":"Sci. Rep."},{"issue":"2","key":"10.1016\/j.ohx.2025.e00647_b13","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1007\/s00221-021-06263-w","article-title":"Galvanic vestibular stimulation as a novel treatment for seasickness","volume":"240","author":"Gutkovich","year":"2022","journal-title":"Exp. Brain Res."},{"key":"10.1016\/j.ohx.2025.e00647_b14","doi-asserted-by":"crossref","first-page":"900","DOI":"10.3389\/fneur.2018.00900","article-title":"Noisy galvanic vestibular stimulation sustainably improves posture in bilateral vestibulopathy","volume":"9","author":"Fujimoto","year":"2018","journal-title":"Front. Neurol."},{"key":"10.1016\/j.ohx.2025.e00647_b15","doi-asserted-by":"crossref","DOI":"10.3389\/fresc.2022.779846","article-title":"Case report: Galvanic vestibular stimulation in the chronic spinal cord injury patient","volume":"3","author":"Nascimento","year":"2022","journal-title":"Front. Rehabil. Sci."},{"key":"10.1016\/j.ohx.2025.e00647_b16","doi-asserted-by":"crossref","DOI":"10.3389\/fnrgo.2022.883962","article-title":"Generating flight illusions using galvanic vestibular stimulation in virtual reality flight simulations","volume":"3","author":"Pradhan","year":"2022","journal-title":"Front. Neuroergonomics"},{"issue":"11","key":"10.1016\/j.ohx.2025.e00647_b17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1371\/journal.pone.0112131","article-title":"Central adaptation to repeated galvanic vestibular stimulation: Implications for pre-flight astronaut training","volume":"9","author":"Dilda","year":"2014","journal-title":"PLOS ONE"},{"issue":"8","key":"10.1016\/j.ohx.2025.e00647_b18","doi-asserted-by":"crossref","first-page":"770","DOI":"10.3357\/ASEM.3051.2011","article-title":"Tolerance to extended galvanic vestibular stimulation: optimal exposure for astronaut training","volume":"82","author":"Dilda","year":"2011","journal-title":"Aviat. Space Environ. Med."},{"issue":"1","key":"10.1016\/j.ohx.2025.e00647_b19","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.neulet.2004.05.015","article-title":"Habituation to galvanic vestibular stimulation for analysis of postural control abilities in gymnasts","volume":"366","author":"Balter","year":"2004","journal-title":"Neurosci. Lett."},{"key":"10.1016\/j.ohx.2025.e00647_b20","doi-asserted-by":"crossref","DOI":"10.11648\/j.ajss.20140202.12","article-title":"The effect of vestibular stimulation on eye-hand coordination and postural control in elite basketball players","author":"Tsang","year":"2014","journal-title":"Am. J. Sport. Sci."},{"issue":"5","key":"10.1016\/j.ohx.2025.e00647_b21","doi-asserted-by":"crossref","first-page":"535","DOI":"10.3357\/ASEM.2942.2011","article-title":"Galvanic vestibular stimulation as an analogue of spatial disorientation after spaceflight","volume":"82","author":"Moore","year":"2011","journal-title":"Aviat. Space, Environ. Med."},{"key":"10.1016\/j.ohx.2025.e00647_b22","series-title":"Motion Sickness","author":"Reason","year":"1975"},{"issue":"5","key":"10.1016\/j.ohx.2025.e00647_b23","doi-asserted-by":"crossref","first-page":"2234","DOI":"10.1109\/TVCG.2022.3150506","article-title":"Omnidirectional galvanic vestibular stimulation in virtual reality","volume":"28","author":"Groth","year":"2022","journal-title":"IEEE Trans. Vis. Comput. Graphics"},{"key":"10.1016\/j.ohx.2025.e00647_b24","series-title":"Effects of Galvanic Vestibular Stimulation During Human Walking","author":"Fitzpatrick","year":"1999"},{"key":"10.1016\/j.ohx.2025.e00647_b25","series-title":"Proceedings of the 2023 CHI Conference on Human Factors in Computing Systems","article-title":"Electrical, vibrational, and cooling stimuli-based redirected walking: Comparison of various vestibular stimulation-based redirected walking systems","author":"Hwang","year":"2023"},{"key":"10.1016\/j.ohx.2025.e00647_b26","series-title":"Proceedings of the Virtual Reality International Conference - Laval Virtual","article-title":"How to use multi-pole galvanic vestibular stimulation for virtual reality application","author":"Nakayama","year":"2018"},{"issue":"2","key":"10.1016\/j.ohx.2025.e00647_b27","first-page":"82","article-title":"Sensory presentation using vestibular sensory electrical stimulation (Japanese title)","volume":"31","author":"Maeda","year":"2007","journal-title":"Soc. Biomech. Jpn."},{"issue":"9","key":"10.1016\/j.ohx.2025.e00647_b28","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1016\/j.clinph.2017.06.001","article-title":"Low intensity transcranial electric stimulation: Safety, ethical, legal regulatory and application guidelines","volume":"128","author":"Antal","year":"2017","journal-title":"Clin. Neurophysiol."},{"issue":"8","key":"10.1016\/j.ohx.2025.e00647_b29","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1109\/10.4599","article-title":"Skin impedance from 1 Hz to 1 MHz","volume":"35","author":"Rosell","year":"1988","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.ohx.2025.e00647_b30","first-page":"3081","article-title":"Reduction of skin impedance by the improvement of the blood circulation","volume":"vol. 3","author":"Bau","year":"2001"},{"issue":"3","key":"10.1016\/j.ohx.2025.e00647_b31","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.clinph.2012.07.028","article-title":"Methods for extra-low voltage transcranial direct current stimulation: Current and time dependent impedance decreases","volume":"124","author":"Hahn","year":"2013","journal-title":"Clin. Neurophysiol."},{"issue":"6","key":"10.1016\/j.ohx.2025.e00647_b32","doi-asserted-by":"crossref","first-page":"2237","DOI":"10.1152\/jn.00035.2019","article-title":"Galvanic vestibular stimulation: from basic concepts to clinical applications","volume":"121","author":"Dlugaiczyk","year":"2019","journal-title":"J. Neurophysiol."},{"key":"10.1016\/j.ohx.2025.e00647_b33","series-title":"2008 IEEE Biomedical Circuits and Systems Conference","first-page":"33","article-title":"Practical considerations for the use of a howland current source for neuro-stimulation","author":"Pouliquen","year":"2008"},{"issue":"1","key":"10.1016\/j.ohx.2025.e00647_b34","first-page":"1","article-title":"Impedance & admittance transformations using operational amplifiers","volume":"12","author":"Sheingold","year":"1964","journal-title":"Light. Empiricist"},{"key":"10.1016\/j.ohx.2025.e00647_b35","series-title":"2010 17th Iranian Conference of Biomedical Engineering","first-page":"1","article-title":"Design and implementation of an ultra low power wireless neuro-stimulator system","author":"Samani","year":"2010"},{"key":"10.1016\/j.ohx.2025.e00647_b36","series-title":"A Comprehensive Study of the Howland Current Pump","author":"Texas Instruments","year":"2008"},{"key":"10.1016\/j.ohx.2025.e00647_b37","series-title":"A large current source with high accuracy and fast settling","author":"Jiang","year":"2018"},{"key":"10.1016\/j.ohx.2025.e00647_b38","doi-asserted-by":"crossref","first-page":"2443","DOI":"10.1007\/s00221-024-06908-6","article-title":"Exploring GVS as a display modality: signal amplitude and polarity, in various environments, impacts on posture, and with dual-tasking","volume":"242","author":"Temple","year":"2024","journal-title":"Exp. Brain Res."},{"key":"10.1016\/j.ohx.2025.e00647_b39","series-title":"LT1013 Low Power Precision Operational Amplifier Datasheet","author":"Texas Instruments","year":"2024"},{"key":"10.1016\/j.ohx.2025.e00647_b40","unstructured":"Marc Teyssier, Uduino, https:\/\/marcteyssier.com\/uduino\/."},{"key":"10.1016\/j.ohx.2025.e00647_b41","doi-asserted-by":"crossref","DOI":"10.1093\/oso\/9780198568131.001.0001","article-title":"Stochastic processes and models","author":"Stirzaker","year":"2005"},{"key":"10.1016\/j.ohx.2025.e00647_b42","doi-asserted-by":"crossref","DOI":"10.3389\/fnins.2023.1156796","article-title":"Scoping out noisy galvanic vestibular stimulation: a review of the parameters used to improve postural control","volume":"17","author":"McLaren","year":"2023","journal-title":"Front. Neurosci."}],"container-title":["HardwareX"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468067225000252?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468067225000252?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T18:53:34Z","timestamp":1762628014000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2468067225000252"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6]]},"references-count":42,"alternative-id":["S2468067225000252"],"URL":"https:\/\/doi.org\/10.1016\/j.ohx.2025.e00647","relation":{},"ISSN":["2468-0672"],"issn-type":[{"value":"2468-0672","type":"print"}],"subject":[],"published":{"date-parts":[[2025,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Design and evaluation of a voltage-controlled current source for galvanic vestibular stimulation research","name":"articletitle","label":"Article Title"},{"value":"HardwareX","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ohx.2025.e00647","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"e00647"}}