{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T16:07:04Z","timestamp":1783786024181,"version":"3.55.0"},"reference-count":41,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2016,5,1]],"date-time":"2016-05-01T00:00:00Z","timestamp":1462060800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","oooojournal.net","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology"],"published-print":{"date-parts":[[2016,5]]},"DOI":"10.1016\/j.oooo.2016.01.013","type":"journal-article","created":{"date-parts":[[2016,1,28]],"date-time":"2016-01-28T12:17:25Z","timestamp":1453983445000},"page":"550-556","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":76,"title":["Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences"],"prefix":"10.1016","volume":"121","author":[{"given":"Sergio Lins","family":"de-Azevedo-Vaz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Priscila Dias","family":"Peyneau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura Ricardina","family":"Ramirez-Sotelo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karla de Faria","family":"Vasconcelos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paulo S\u00e9rgio Flores","family":"Campos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Haiter-Neto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.oooo.2016.01.013_bib1","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1097\/ID.0b013e3181676059","article-title":"Implant success, survival, and failure: the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference","volume":"17","author":"Misch","year":"2008","journal-title":"Implant Dent"},{"key":"10.1016\/j.oooo.2016.01.013_bib2","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1111\/j.1600-0501.2005.01106.x","article-title":"Long-term results and survival rate of implants treated with guided bone regeneration: a 5-year case series prospective study","volume":"16","author":"Blanco","year":"2005","journal-title":"Clin Oral Impl Res"},{"key":"10.1016\/j.oooo.2016.01.013_bib3","doi-asserted-by":"crossref","first-page":"S109","DOI":"10.1016\/j.ajodo.2009.07.013","article-title":"Accuracy and reliability of cone-beam computed tomography for measuring alveolar bone height and detecting bony dehiscences and fenestrations","volume":"137","author":"Leung","year":"2010","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.oooo.2016.01.013_bib4","first-page":"174","article-title":"Metal artifact reduction in cone beam computed tomography using forward projected reconstruction information","volume":"21","author":"Meilinger","year":"2011","journal-title":"Z\u00a0Med Phys"},{"key":"10.1016\/j.oooo.2016.01.013_bib5","doi-asserted-by":"crossref","first-page":"20120245","DOI":"10.1259\/dmfr.20120245","article-title":"Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth","volume":"42","author":"Bechara","year":"2013","journal-title":"Dentomaxillofac Radiol"},{"key":"10.1016\/j.oooo.2016.01.013_bib6","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1259\/dmfr\/30642039","article-title":"Artefacts in CBCT: a review","volume":"40","author":"Schulze","year":"2011","journal-title":"Dentomaxillofac Radiol"},{"key":"10.1016\/j.oooo.2016.01.013_bib7","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1111\/j.1600-0501.2009.01905.x","article-title":"Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography","volume":"21","author":"Razavi","year":"2010","journal-title":"Clin Oral Impl Res"},{"key":"10.1016\/j.oooo.2016.01.013_bib8","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.oooo.2012.10.003","article-title":"Detection of periimplant fenestration and dehiscence with the use of two scan modes and the smallest voxel sizes of a cone-beam computed tomography device","volume":"115","author":"de-Azevedo-Vaz","year":"2013","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"key":"10.1016\/j.oooo.2016.01.013_bib9","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"10.1016\/j.oooo.2016.01.013_bib10","unstructured":"Eng J. ROC analysis: web-based calculator for ROC curves; updated 2006. Baltimore, MD: Johns Hopkins University. Available at: http:\/\/www.jrocfit.org\/. Accessed November 4,\u00a02015."},{"key":"10.1016\/j.oooo.2016.01.013_bib11","doi-asserted-by":"crossref","first-page":"1679","DOI":"10.1148\/rg.246045065","article-title":"Artifacts in CT: recognition and avoidance","volume":"24","author":"Barrett","year":"2004","journal-title":"Radiographies"},{"key":"10.1016\/j.oooo.2016.01.013_bib12","first-page":"850","article-title":"Common orthodontic appliances cause artifacts that degrade the diagnostic quality of CBCT images","volume":"35","author":"Sanders","year":"2007","journal-title":"J\u00a0Calif Dent Assoc"},{"key":"10.1016\/j.oooo.2016.01.013_bib13","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1259\/dmfr\/32579161","article-title":"Beam hardening artefacts occur in dental implant scans with the NewTom\u00ae cone beam CT but not with the dental 4-row multidetector CT","volume":"36","author":"Draenert","year":"2007","journal-title":"Dentomaxillofc Radiol"},{"key":"10.1016\/j.oooo.2016.01.013_bib14","doi-asserted-by":"crossref","first-page":"7042","DOI":"10.1118\/1.4762289","article-title":"A\u00a0fully 3 D approach for metal artifact reduction in computed tomography","volume":"39","author":"Kratz","year":"2012","journal-title":"Med Phys"},{"key":"10.1016\/j.oooo.2016.01.013_bib15","doi-asserted-by":"crossref","first-page":"20130176","DOI":"10.1259\/dmfr.20130176","article-title":"Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode","volume":"42","author":"Kamburo\u011flu","year":"2013","journal-title":"Dentomaxillofac Radiol"},{"key":"10.1016\/j.oooo.2016.01.013_bib16","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1118\/1.1339879","article-title":"Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter","volume":"28","author":"Siewerdsen","year":"2001","journal-title":"Med Phys"},{"key":"10.1016\/j.oooo.2016.01.013_bib17","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1118\/1.1357457","article-title":"Effect of scattered radiation on image noise in cone beam CT","volume":"28","author":"Endo","year":"2001","journal-title":"Med Phys"},{"key":"10.1016\/j.oooo.2016.01.013_bib18","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1117\/12.535387","article-title":"Performance of standard fluoroscopy antiscatter grids in flat-detector-based cone-beam CT","volume":"5368","author":"Wiegert","year":"2004","journal-title":"Proc SPIE Medical Imaging"},{"key":"10.1016\/j.oooo.2016.01.013_bib19","doi-asserted-by":"crossref","first-page":"3506","DOI":"10.1118\/1.1819789","article-title":"The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors","volume":"31","author":"Siewerdsen","year":"2004","journal-title":"Med Phys"},{"key":"10.1016\/j.oooo.2016.01.013_bib20","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1088\/0031-9155\/55\/3\/016","article-title":"An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements","volume":"55","author":"Kim","year":"2010","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.oooo.2016.01.013_bib21","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1097\/01.rli.0000086495.96457.54","article-title":"New algorithm for metal artifact reduction in computed tomography: in\u00a0vitro and in\u00a0vivo evaluation after total hip replacement","volume":"38","author":"Mahnken","year":"2003","journal-title":"Invest Radiol"},{"key":"10.1016\/j.oooo.2016.01.013_bib22","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1097\/00004728-198803000-00012","article-title":"Evaluation of CT techniques for reduction artifacts in the presence of metallic orthopedic implants","volume":"12","author":"Robertson","year":"1988","journal-title":"J\u00a0Comput Assist Tomogr"},{"key":"10.1016\/j.oooo.2016.01.013_bib23","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1259\/dmfr\/80899839","article-title":"Metal artefact reduction with cone beam CT: an in\u00a0vitro study","volume":"41","author":"Bechara","year":"2012","journal-title":"Dentomaxillofac Radiol"},{"key":"10.1016\/j.oooo.2016.01.013_bib24","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1016\/j.oooo.2013.01.026","article-title":"Number of basis images effect on detection of root fractures in endodontically treated teeth using a cone beam computed tomography machine: an in\u00a0vitro study","volume":"115","author":"Bechara","year":"2013","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"key":"10.1016\/j.oooo.2016.01.013_bib25","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1111\/iej.12395","article-title":"Artefact expression associated with several cone-beam computed tomographic machines when imaging root filled teeth","volume":"48","author":"Vasconcelos","year":"2015","journal-title":"Int Endod J"},{"key":"10.1016\/j.oooo.2016.01.013_bib26","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1109\/23.856534","article-title":"Reduction of metal streak artifacts in x ray computed tomography using a transmission maximum a posteriori algorithm","volume":"47","author":"Man","year":"2000","journal-title":"IEEE Trans Nucl Sci"},{"key":"10.1016\/j.oooo.2016.01.013_bib27","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1109\/42.538943","article-title":"Iterative deblurring for CT metal artifact reduction","volume":"15","author":"Wang","year":"1996","journal-title":"IEEE Trans Med Imag"},{"key":"10.1016\/j.oooo.2016.01.013_bib28","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1259\/dmfr\/25260548","article-title":"Dental CT metal artefact reduction based on sequential substitution","volume":"40","author":"Tohnak","year":"2011","journal-title":"Dentomaxillofac Radiol"},{"key":"10.1016\/j.oooo.2016.01.013_bib29","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1902\/jop.2006.050424","article-title":"Digital volume tomography in the diagnosis of peri-implant defects: an in\u00a0vitro study on native pig mandibles","volume":"77","author":"Mengel","year":"2006","journal-title":"J\u00a0Periodontol"},{"key":"10.1016\/j.oooo.2016.01.013_bib30","doi-asserted-by":"crossref","first-page":"3 S","DOI":"10.14219\/jada.archive.2010.0359","article-title":"Operational principles for cone-beam computed tomography","volume":"141","author":"Hatcher","year":"2010","journal-title":"J\u00a0Am Dent Assoc"},{"key":"10.1016\/j.oooo.2016.01.013_bib31","doi-asserted-by":"crossref","first-page":"e117","DOI":"10.1016\/j.ajodo.2010.08.016","article-title":"Effect of bone thickness on alveolar bone-height measurements from cone beam computed tomography images","volume":"139","author":"Sun","year":"2011","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.oooo.2016.01.013_bib32","first-page":"233","article-title":"Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption","volume":"35","author":"Liedke","year":"2009","journal-title":"J\u00a0Endod"},{"key":"10.1016\/j.oooo.2016.01.013_bib33","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1111\/j.1365-2591.2011.01966.x","article-title":"Evaluation of reconstructed images with different voxel sizes of acquisition in the diagnosis of simulated external root resorption using cone beam computed tomography","volume":"45","author":"Neves","year":"2012","journal-title":"Int Endod J"},{"key":"10.1016\/j.oooo.2016.01.013_bib34","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1111\/j.1365-2591.2010.01749.x","article-title":"A\u00a0comparison of the diagnostic accuracy of CBCT images of different voxel resolutions used to detect simulated small internal resorption cavities","volume":"43","author":"Kamburo\u011flu","year":"2010","journal-title":"Int Endod J"},{"key":"10.1016\/j.oooo.2016.01.013_bib35","doi-asserted-by":"crossref","first-page":"e63","DOI":"10.1016\/j.tripleo.2009.12.048","article-title":"Occlusal caries detection by using a cone-beam CT with different voxel resolutions and a digital intraoral sensor","volume":"109","author":"Kamburo\u011flu","year":"2010","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.oooo.2016.01.013_bib36","first-page":"1879","article-title":"Diagnostic ability of a cone-beam computed tomography scan to assess longitudinal root fractures in prosthetically treated teeth","volume":"36","author":"Melo","year":"2010","journal-title":"J\u00a0Endod"},{"key":"10.1016\/j.oooo.2016.01.013_bib37","first-page":"75","article-title":"Detection of vertical root fractures by using cone beam computed tomography with variable voxel sizes in an in\u00a0vitro model","volume":"37","author":"\u00d6zer","year":"2011","journal-title":"J\u00a0Endod"},{"key":"10.1016\/j.oooo.2016.01.013_bib38","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1902\/jop.2012.110524","article-title":"Accuracy of linear measurements and visibility of the mandibular canal on cone-beam computed tomography images with different voxel sizes: an in\u00a0vitro study","volume":"84","author":"Waltrick","year":"2013","journal-title":"J\u00a0Periodontol"},{"key":"10.1016\/j.oooo.2016.01.013_bib39","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1097\/ID.0b013e31824bf93c","article-title":"Accuracy of linear measurements in cone beam computed tomography with different voxel sizes","volume":"21","author":"Torres","year":"2012","journal-title":"Implant Dent"},{"key":"10.1016\/j.oooo.2016.01.013_bib40","doi-asserted-by":"crossref","first-page":"20130332","DOI":"10.1259\/dmfr.20130332","article-title":"Accuracy of CBCT images in the assessment of buccal marginal alveolar peri-implant defects: effect of field of view","volume":"43","author":"Kamburo\u011flu","year":"2014","journal-title":"Dentomaxillofac Radiol"},{"key":"10.1016\/j.oooo.2016.01.013_bib41","doi-asserted-by":"crossref","first-page":"133.e1-e7","DOI":"10.1016\/j.ajodo.2010.02.021","article-title":"Dehiscence and fenestration in patients with Class I and Class II Division 1 malocclusion assessed with cone-beam computed tomography","volume":"138","author":"Evangelista","year":"2010","journal-title":"Am J Orthod Dentofacial Orthop"}],"container-title":["Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212440316000158?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212440316000158?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,15]],"date-time":"2018-09-15T22:56:18Z","timestamp":1537052178000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2212440316000158"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5]]},"references-count":41,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2016,5]]}},"alternative-id":["S2212440316000158"],"URL":"https:\/\/doi.org\/10.1016\/j.oooo.2016.01.013","relation":{},"ISSN":["2212-4403"],"issn-type":[{"value":"2212-4403","type":"print"}],"subject":[],"published":{"date-parts":[[2016,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences","name":"articletitle","label":"Article Title"},{"value":"Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.oooo.2016.01.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2016 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}