{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T16:21:36Z","timestamp":1774974096976,"version":"3.50.1"},"reference-count":24,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2008,8,1]],"date-time":"2008-08-01T00:00:00Z","timestamp":1217548800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2008,8,1]],"date-time":"2008-08-01T00:00:00Z","timestamp":1217548800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100011434","name":"Pennsylvania Academy of Science","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100011434","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000053","name":"National Eye Institute","doi-asserted-by":"publisher","award":["EY08208"],"award-info":[{"award-number":["EY08208"]}],"id":[{"id":"10.13039\/100000053","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000053","name":"National Eye Institute","doi-asserted-by":"publisher","award":["EY11008"],"award-info":[{"award-number":["EY11008"]}],"id":[{"id":"10.13039\/100000053","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["aaojournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmology"],"published-print":{"date-parts":[[2008,8]]},"DOI":"10.1016\/j.ophtha.2007.11.008","type":"journal-article","created":{"date-parts":[[2008,1,24]],"date-time":"2008-01-24T15:57:31Z","timestamp":1201190251000},"page":"1340-1346","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":67,"title":["Comparison of Retinal Nerve Fiber Layer and Optic Disc Imaging for Diagnosing Glaucoma in Patients Suspected of Having the Disease"],"prefix":"10.1016","volume":"115","author":[{"given":"Felipe A.","family":"Medeiros","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gianmarco","family":"Vizzeri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Linda M.","family":"Zangwill","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luciana M.","family":"Alencar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pamela A.","family":"Sample","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert N.","family":"Weinreb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ophtha.2007.11.008_bib1","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1016\/S0002-9394(14)70221-1","article-title":"Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes","volume":"119","author":"Weinreb","year":"1995","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib2","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1001\/archopht.122.5.698","article-title":"Comparison of scanning laser polarimetry using variable corneal compensation and retinal nerve fiber layer photography for detection of glaucoma","volume":"122","author":"Medeiros","year":"2004","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib3","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1001\/archopht.116.9.1229","article-title":"Assessment of optic disc topography for diagnosing and monitoring glaucoma","volume":"116","author":"Weinreb","year":"1998","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib4","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1001\/archopht.122.6.827","article-title":"Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and Stratus OCT optical coherence tomograph for the detection of glaucoma","volume":"122","author":"Medeiros","year":"2004","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib5","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1167\/iovs.05-1133","article-title":"Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma","volume":"47","author":"Medeiros","year":"2006","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2007.11.008_bib6","doi-asserted-by":"crossref","first-page":"3374","DOI":"10.1167\/iovs.05-1239","article-title":"Discrimination between glaucomatous and nonglaucomatous eyes using quantitative imaging devices and subjective optic nerve head assessment","volume":"47","author":"Deleon-Ortega","year":"2006","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2007.11.008_bib7","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1136\/bjo.2006.096586","article-title":"Accuracy of GDx VCC, HRT I, and clinical assessment of stereoscopic optic nerve head photographs for diagnosing glaucoma","volume":"91","author":"Reus","year":"2007","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib8","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1007\/s00417-005-0029-0","article-title":"Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage","volume":"244","author":"Kanamori","year":"2006","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib9","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1136\/bjo.2006.107409","article-title":"How should diagnostic tests be evaluated in glaucoma?","volume":"91","author":"Medeiros","year":"2007","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib10","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1167\/iovs.06-0618","article-title":"The effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy in glaucoma","volume":"48","author":"Medeiros","year":"2007","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2007.11.008_bib11","doi-asserted-by":"crossref","first-page":"1010","DOI":"10.1016\/j.ajo.2005.01.003","article-title":"Use of progressive glaucomatous optic disk change as the reference standard for evaluation of diagnostic tests in glaucoma","volume":"139","author":"Medeiros","year":"2005","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib12","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1001\/archopht.1990.01070060105058","article-title":"Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness","volume":"108","author":"Weinreb","year":"1990","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib13","first-page":"2221","article-title":"Individualized compensation of anterior segment birefringence during scanning laser polarimetry","volume":"43","author":"Zhou","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2007.11.008_bib14","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1167\/iovs.06-0787","article-title":"The effect of atypical birefringence patterns on glaucoma detection using scanning laser polarimetry with variable corneal compensation","volume":"48","author":"Bowd","year":"2007","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2007.11.008_bib15","doi-asserted-by":"crossref","first-page":"1322","DOI":"10.1167\/iovs.04-1122","article-title":"Relevance vector machine and support vector machine classifier analysis of scanning laser polarimetry retinal nerve fiber layer measurements","volume":"46","author":"Bowd","year":"2005","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2007.11.008_bib16","first-page":"3","article-title":"Laser scanning tomography to diagnose and monitor glaucoma","volume":"4","author":"Weinreb","year":"1993","journal-title":"Curr Opin Ophthalmol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib17","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1097\/00061198-199508000-00005","article-title":"Ability of the Heidelberg retina tomograph to detect early glaucomatous visual field loss","volume":"4","author":"Mikelberg","year":"1995","journal-title":"J Glaucoma"},{"key":"10.1016\/j.ophtha.2007.11.008_bib18","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.1016\/S0161-6420(98)98047-2","article-title":"Identification of early glaucoma cases with the scanning laser ophthalmoscope","volume":"105","author":"Wollstein","year":"1998","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2007.11.008_bib19","first-page":"1730","article-title":"Automated analysis of normal and glaucomatous optic nerve head topography images","volume":"41","author":"Swindale","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2007.11.008_bib20","doi-asserted-by":"crossref","first-page":"364","DOI":"10.2214\/ajr.184.2.01840364","article-title":"ROC analysis","volume":"184","author":"Obuchowski","year":"2005","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib21","doi-asserted-by":"crossref","first-page":"837","DOI":"10.2307\/2531595","article-title":"Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach","volume":"44","author":"DeLong","year":"1988","journal-title":"Biometrics"},{"key":"10.1016\/j.ophtha.2007.11.008_bib22","doi-asserted-by":"crossref","first-page":"1798","DOI":"10.1161\/01.CIR.96.6.1798","article-title":"Acute myocardial infarction detected in the 12-lead ECG by artificial neural networks","volume":"96","author":"Heden","year":"1997","journal-title":"Circulation"},{"key":"10.1016\/j.ophtha.2007.11.008_bib23","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1016\/0002-9149(83)90508-8","article-title":"Electrocardiographic and clinical criteria for recognition of acute myocardial infarction based on analysis of 3,697 patients","volume":"52","author":"Rude","year":"1983","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.ophtha.2007.11.008_bib24","doi-asserted-by":"crossref","first-page":"3146","DOI":"10.1001\/jama.1993.03500240090032","article-title":"The accuracy of magnetic resonance imaging in patients with suspected multiple sclerosis","volume":"269","author":"Mushlin","year":"1993","journal-title":"JAMA"}],"container-title":["Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S016164200701233X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S016164200701233X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T13:56:00Z","timestamp":1758981360000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S016164200701233X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,8]]},"references-count":24,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2008,8]]}},"alternative-id":["S016164200701233X"],"URL":"https:\/\/doi.org\/10.1016\/j.ophtha.2007.11.008","relation":{},"ISSN":["0161-6420"],"issn-type":[{"value":"0161-6420","type":"print"}],"subject":[],"published":{"date-parts":[[2008,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of Retinal Nerve Fiber Layer and Optic Disc Imaging for Diagnosing Glaucoma in Patients Suspected of Having the Disease","name":"articletitle","label":"Article Title"},{"value":"Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ophtha.2007.11.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2008 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}