{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T01:38:58Z","timestamp":1789090738979,"version":"build-2803163510"},"reference-count":36,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2009,9,1]],"date-time":"2009-09-01T00:00:00Z","timestamp":1251763200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2009,9,1]],"date-time":"2009-09-01T00:00:00Z","timestamp":1251763200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["aaojournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmology"],"published-print":{"date-parts":[[2009,9]]},"DOI":"10.1016\/j.ophtha.2009.03.052","type":"journal-article","created":{"date-parts":[[2009,7,30]],"date-time":"2009-07-30T10:56:36Z","timestamp":1248951396000},"page":"1697-1706","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":76,"title":["Effect of Intraocular Lens Asphericity on Quality of Vision after Cataract Removal"],"prefix":"10.1016","volume":"116","author":[{"given":"Thomas","family":"Kohnen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oliver K.","family":"Klaproth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens","family":"B\u00fchren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ophtha.2009.03.052_bib1","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1001\/archopht.1994.01090140115033","article-title":"Synthesis of the literature on visual acuity and complications following cataract extraction with intraocular lens implantation","volume":"112","author":"Powe","year":"1994","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2009.03.052_bib3","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.ophtha.2004.06.030","article-title":"Incision sizes before and after implantation of 6-mm optic foldable intraocular lenses using Monarch and Unfolder injector systems","volume":"112","author":"Kohnen","year":"2005","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2009.03.052_bib4","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1016\/j.ophtha.2008.01.002","article-title":"Optic edge design as long-term factor for posterior capsular opacification rates","volume":"115","author":"Kohnen","year":"2008","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2009.03.052_bib5","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1097\/01.opx.0000216100.93302.2d","article-title":"Measuring contrast sensitivity under different lighting conditions: comparison of three tests","volume":"83","author":"B\u00fchren","year":"2006","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ophtha.2009.03.052_bib6","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1007\/s00347-004-1125-y","article-title":"[Frankfurt-Freiburg Contrast and Acuity Test System (FF-CATS)","volume":"102","author":"Terzi","year":"2005","journal-title":"Ophthalmologe"},{"key":"10.1016\/j.ophtha.2009.03.052_bib7","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1016\/j.ajo.2006.06.031","article-title":"Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study","volume":"142","author":"Rocha","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ophtha.2009.03.052_bib8","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1097\/01.OPX.0000162647.80768.7F","article-title":"Image metrics for predicting subjective image quality","volume":"82","author":"Chen","year":"2005","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ophtha.2009.03.052_bib9","doi-asserted-by":"crossref","first-page":"579","DOI":"10.3928\/1081-597X-20030901-14","article-title":"Estimating visual quality from wavefront aberration measurement","volume":"19","author":"Cheng","year":"2003","journal-title":"J Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib10","series-title":"Cataract and Refractive Surgery","first-page":"303","article-title":"Quality of vision after refractive surgery","author":"Kohnen","year":"2004"},{"key":"10.1016\/j.ophtha.2009.03.052_bib11","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.1016\/S0886-3350(03)00467-X","article-title":"Optical aberrations of the human anterior cornea","volume":"29","author":"Wang","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib12","doi-asserted-by":"crossref","first-page":"1512","DOI":"10.1016\/j.jcrs.2004.01.048","article-title":"Higher-order aberrations from the internal optics of the eye","volume":"31","author":"Wang","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib13","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1016\/j.jcrs.2003.10.022","article-title":"Improved functional vision with a modified prolate intraocular lens","volume":"30","author":"Packer","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib14","doi-asserted-by":"crossref","first-page":"692","DOI":"10.3928\/1081-597X-20021101-05","article-title":"Prospective randomized trial of an anterior surface modified prolate intraocular lens","volume":"18","author":"Packer","year":"2002","journal-title":"J Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib15","doi-asserted-by":"crossref","first-page":"683","DOI":"10.3928\/1081-597X-20021101-04","article-title":"A new intraocular lens design to reduce spherical aberration of pseudophakic eyes","volume":"18","author":"Holladay","year":"2002","journal-title":"J Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib16","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1007\/s00347-008-1718-y","article-title":"[Aspheric intraocular lenses]","volume":"105","author":"Kohnen","year":"2008","journal-title":"Ophthalmologe"},{"key":"10.1016\/j.ophtha.2009.03.052_bib17","doi-asserted-by":"crossref","first-page":"1409","DOI":"10.1016\/j.jcrs.2007.04.022","article-title":"Rate of posterior capsule opacification in eyes with the Akreos intraocular lens","volume":"33","author":"Khandwala","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib18","doi-asserted-by":"crossref","first-page":"2022","DOI":"10.1016\/j.jcrs.2006.07.029","article-title":"Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations","volume":"32","author":"Kasper","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib19","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.jcrs.2005.11.018","article-title":"Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter","volume":"32","author":"Kasper","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib20","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1016\/S0886-3350(02)01983-1","article-title":"Impact of a modified optic design on visual function: clinical comparative study","volume":"29","author":"Mester","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib21","doi-asserted-by":"crossref","first-page":"1841","DOI":"10.1364\/JOSAA.20.001841","article-title":"Optical aberrations of intraocular lenses measured in vivo and in vitro","volume":"20","author":"Barbero","year":"2003","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"10.1016\/j.ophtha.2009.03.052_bib22","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/01.opx.0000195563.82891.3b","article-title":"Computational aspects of the visual Strehl ratio","volume":"83","author":"Iskander","year":"2006","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ophtha.2009.03.052_bib23","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1007\/s00417-006-0474-4","article-title":"The Freiburg Visual Acuity Test-variability unchanged by post-hoc re-analysis","volume":"245","author":"Bach","year":"2007","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"10.1016\/j.ophtha.2009.03.052_bib24","doi-asserted-by":"crossref","first-page":"1633","DOI":"10.1016\/j.visres.2005.06.009","article-title":"Accommodation stimulus-response function and retinal image quality","volume":"46","author":"B\u00fchren","year":"2006","journal-title":"Vision Res"},{"key":"10.1016\/j.ophtha.2009.03.052_bib25","doi-asserted-by":"crossref","first-page":"1684","DOI":"10.1016\/S0886-3350(03)00523-6","article-title":"Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses; prospective evaluation","volume":"29","author":"Kershner","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib26","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.jcrs.2004.08.049","article-title":"Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study","volume":"31","author":"Bellucci","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib27","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1016\/j.jcrs.2006.02.055","article-title":"Spherical aberration and contrast sensitivity after cataract surgery with the Tecnis Z9000 intraocular lens","volume":"32","author":"Munoz","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib28","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.jcrs.2004.09.028","article-title":"Effect of cataract surgery incision location and intraocular lens type on ocular aberrations","volume":"31","author":"Pesudovs","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib29","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1007\/s00347-004-1058-5","article-title":"[Higher order aberrations after implantation of an iris claw pIOL (Ophtec Artisan) in the phakic eye]","volume":"101","author":"B\u00fchren","year":"2004","journal-title":"Ophthalmologe"},{"key":"10.1016\/j.ophtha.2009.03.052_bib30","doi-asserted-by":"crossref","first-page":"2064","DOI":"10.1016\/j.jcrs.2006.07.022","article-title":"Normal-eye Zernike coefficients and root-mean-square wavefront errors","volume":"32","author":"Salmon","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib31","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.jcrs.2006.10.068","article-title":"Spherical aberration and coma with an aspherical and a spherical intraocular lens in normal age-matched eyes","volume":"33","author":"Bellucci","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib32","doi-asserted-by":"crossref","first-page":"1611","DOI":"10.1016\/S0042-6989(02)00085-8","article-title":"Ocular wave-front aberration statistics in a normal young population","volume":"42","author":"Castejon-Mochon","year":"2002","journal-title":"Vision Res"},{"key":"10.1016\/j.ophtha.2009.03.052_bib33","unstructured":"Baumeister M, B\u00fchren J, Kohnen T. Effect of tilt and decentration on higher-order aberrations in spherical and aspherical intraocular lenses. J Cataract Refract Surg. In press."},{"key":"10.1016\/j.ophtha.2009.03.052_bib34","doi-asserted-by":"crossref","first-page":"50814","DOI":"10.3928\/1081-597X-20040901-20","article-title":"Measuring Visual acuity\u2014mesopic or photopic conditions, and high or low contrast letters?","volume":"20","author":"Pesudovs","year":"2004","journal-title":"J Refractive Surgery"},{"key":"10.1016\/j.ophtha.2009.03.052_bib35","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1007\/s00347-007-1545-6","article-title":"[Wavefront aberrations and subjective quality of vision after wavefront-guided LASIK: first results]","volume":"104","author":"B\u00fchren","year":"2007","journal-title":"Ophthalmologe"},{"key":"10.1016\/j.ophtha.2009.03.052_bib36","doi-asserted-by":"crossref","first-page":"2073","DOI":"10.1016\/j.jcrs.2003.07.007","article-title":"Effect of intraocular lens implantation on visual acuity, contrast sensitivity, and depth of focus","volume":"29","author":"Nio","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.ophtha.2009.03.052_bib37","doi-asserted-by":"crossref","first-page":"2050","DOI":"10.1016\/j.ophtha.2007.01.024","article-title":"Spherical aberration and depth of focus in eyes implanted with aspheric and spherical intraocular lenses: a prospective randomized study","volume":"114","author":"Rocha","year":"2007","journal-title":"Ophthalmology"}],"container-title":["Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0161642009003492?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0161642009003492?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T13:58:55Z","timestamp":1758981535000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0161642009003492"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,9]]},"references-count":36,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2009,9]]}},"alternative-id":["S0161642009003492"],"URL":"https:\/\/doi.org\/10.1016\/j.ophtha.2009.03.052","relation":{},"ISSN":["0161-6420"],"issn-type":[{"value":"0161-6420","type":"print"}],"subject":[],"published":{"date-parts":[[2009,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of Intraocular Lens Asphericity on Quality of Vision after Cataract Removal","name":"articletitle","label":"Article Title"},{"value":"Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ophtha.2009.03.052","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2009 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}