{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T16:37:49Z","timestamp":1788885469090,"version":"build-2803163510"},"reference-count":34,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2012,10,1]],"date-time":"2012-10-01T00:00:00Z","timestamp":1349049600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2012,10,1]],"date-time":"2012-10-01T00:00:00Z","timestamp":1349049600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["aaojournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmology"],"published-print":{"date-parts":[[2012,10]]},"DOI":"10.1016\/j.ophtha.2012.03.051","type":"journal-article","created":{"date-parts":[[2012,6,15]],"date-time":"2012-06-15T22:04:33Z","timestamp":1339797873000},"page":"2014-2020","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":19,"title":["Visual Function after Correction of Distance Refractive Error with Ready-made and Custom Spectacles: A Randomized Clinical Trial"],"prefix":"10.1016","volume":"119","clinical-trial-number":[{"clinical-trial-number":"nct00657670","registry":"10.18810\/clinical-trials-gov"}],"author":[{"given":"Christopher J.","family":"Brady","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea C.","family":"Villanti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Monica","family":"Gandhi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David S.","family":"Friedman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lisa","family":"Keay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ophtha.2012.03.051_bib1","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1016\/S1474-4422(07)70290-9","article-title":"Rating scales as outcome measures for clinical trials in neurology: problems, solutions, and recommendations","volume":"6","author":"Hobart","year":"2007","journal-title":"Lancet Neurol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib2","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1186\/1477-7525-4-79","article-title":"Guidance for industry: patient-reported outcome measures: use in medical product development to support labeling claims: draft guidance","volume":"4","year":"2006","journal-title":"Health Qual Life Outcomes [serial online]"},{"key":"10.1016\/j.ophtha.2012.03.051_bib3","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1136\/bmj.324.7351.1417","article-title":"Quality of life measurement: bibliographic study of patient assessed health outcome measures [report online]","volume":"324","author":"Garratt","year":"2002","journal-title":"BMJ"},{"key":"10.1016\/j.ophtha.2012.03.051_bib4","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/ICU.0b013e3283414284","article-title":"The impact of cataract surgery on quality of life","volume":"22","author":"Lamoureux","year":"2011","journal-title":"Curr Opin Ophthalmol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib5","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1016\/j.ophtha.2010.08.003","article-title":"Severity of diabetic retinopathy and health-related quality of life: the Los Angeles Latino Eye Study","volume":"118","author":"Mazhar","year":"2011","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2012.03.051_bib6","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.ophtha.2004.06.036","article-title":"Vision-related quality of life in patients with bilateral severe age-related macular degeneration","volume":"112","author":"Cahill","year":"2005","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2012.03.051_bib7","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1016\/j.ophtha.2007.08.037","article-title":"Impact of visual field loss on health-related quality of life in glaucoma: the Los Angeles Latino Eye Study","volume":"115","author":"McKean-Cowdin","year":"2008","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2012.03.051_bib8","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1097\/00006324-200410000-00009","article-title":"The Quality of Life Impact of Refractive Correction (QIRC) Questionnaire: development and validation","volume":"81","author":"Pesudovs","year":"2004","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ophtha.2012.03.051_bib9","first-page":"6","article-title":"What is the global burden of visual impairment?","volume":"4","author":"Dandona","year":"2006","journal-title":"BMC Med [serial online]"},{"key":"10.1016\/j.ophtha.2012.03.051_bib10","doi-asserted-by":"crossref","first-page":"63","DOI":"10.2471\/BLT.07.041210","article-title":"Global magnitude of visual impairment caused by uncorrected refractive errors in 2004","volume":"86","author":"Resnikoff","year":"2008","journal-title":"Bull World Health Organ"},{"key":"10.1016\/j.ophtha.2012.03.051_bib11","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1016\/j.ophtha.2010.09.015","article-title":"Uncorrected refractive error in a Latino population: Proyecto VER","volume":"118","author":"Uribe","year":"2011","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2012.03.051_bib12","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1111\/j.1444-0938.2007.00193.x","article-title":"The rationale for shifting from a voluntary clinical approach to a public health approach in addressing refractive errors","volume":"90","author":"Vincent","year":"2007","journal-title":"Clin Exp Optom"},{"key":"10.1016\/j.ophtha.2012.03.051_bib13","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1136\/bjo.2004.047498","article-title":"Impact of unilateral and bilateral vision loss on quality of life","volume":"89","author":"Vu","year":"2005","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib14","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1001\/archopht.122.4.615","article-title":"VISION 2020: The Right to Sight: a global initiative to eliminate avoidable blindness","volume":"122","author":"Pizzarello","year":"2004","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib15","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1001\/archopht.126.10.1457","article-title":"Global blindness: VISION 2020: the Right to Sight","volume":"126","author":"Chandra","year":"2008","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib16","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1111\/j.1444-0938.2010.00455.x","article-title":"The challenge of uncorrected refractive error: driving the agenda of the Durban Declaration on refractive error and service development","volume":"93","author":"Naidoo","year":"2010","journal-title":"Clin Exp Optom"},{"key":"10.1016\/j.ophtha.2012.03.051_bib17","doi-asserted-by":"crossref","first-page":"431","DOI":"10.2471\/BLT.08.055673","article-title":"Potential lost productivity resulting from the global burden of uncorrected refractive error","volume":"87","author":"Smith","year":"2009","journal-title":"Bull World Health Organ"},{"key":"10.1016\/j.ophtha.2012.03.051_bib18","doi-asserted-by":"crossref","first-page":"1731","DOI":"10.1001\/archopht.126.12.1731","article-title":"Global vision impairment due to uncorrected presbyopia","volume":"126","author":"Holden","year":"2008","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib19","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/1471-2415-10-12","article-title":"Refractive ocular conditions and reasons for spectacles renewal in a resource-limited economy","volume":"10","author":"Ayanniyi","year":"2010","journal-title":"BMC Ophthalmol [serial online]"},{"key":"10.1016\/j.ophtha.2012.03.051_bib20","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1111\/j.1442-9071.2008.01768.x","article-title":"Public sector refraction and spectacle dispensing in low-resource countries of the Western Pacific","volume":"36","author":"Ramke","year":"2008","journal-title":"Clin Experiment Ophthalmol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib21","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1136\/bjo.2007.122192","article-title":"Using assessment of willingness to pay to improve a Cambodian spectacle service","volume":"92","author":"Ramke","year":"2008","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib22","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1097\/OPX.0b013e3181b487f6","article-title":"Applying standards to readymade spectacles used in low-resource countries","volume":"86","author":"Ramke","year":"2009","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ophtha.2012.03.051_bib23","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1097\/01.opx.0000239126.46172.80","article-title":"Simple spectacles for adult refugees on the Thailand-Burma border","volume":"83","author":"Vincent","year":"2006","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ophtha.2012.03.051_bib24","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1093\/ije\/dyp384","article-title":"A randomized clinical trial to evaluate ready-made spectacles in an adult population in India","volume":"39","author":"Keay","year":"2010","journal-title":"Int J Epidemiol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib25","doi-asserted-by":"crossref","first-page":"1839","DOI":"10.1016\/j.ophtha.2009.04.004","article-title":"A randomized, clinical trial evaluating ready-made and custom spectacles delivered via a school-based screening program in China","volume":"116","author":"Zeng","year":"2009","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2012.03.051_bib26","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1136\/bjo.85.11.1283","article-title":"Correction of refractive error in the Victorian population: the feasibility of \u201coff the shelf\u201d spectacles","volume":"85","author":"Maini","year":"2001","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib27","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1097\/OPX.0b013e318159aa69","article-title":"Tolerance to prism induced by readymade spectacles: setting and using a standard","volume":"84","author":"du Toit","year":"2007","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ophtha.2012.03.051_bib28","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1167\/iovs.03-0129","article-title":"Correction of refractive error in the adult population of Bangladesh: meeting the unmet need","volume":"45","author":"Bourne","year":"2004","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2012.03.051_bib29","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1001\/archophthalmol.2010.215","article-title":"Predictors of early acceptance of free spectacles provided to junior high school students in China","volume":"128","author":"Keay","year":"2010","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib30","doi-asserted-by":"crossref","first-page":"282","DOI":"10.3109\/09286586.2010.511756","article-title":"Validation of a visual function and quality of life instrument in an urban Indian population with uncorrected refractive error using Rasch analysis","volume":"17","author":"Brady","year":"2010","journal-title":"Ophthalmic Epidemiol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib31","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1016\/j.visres.2005.07.007","article-title":"The Refractive Status and Vision Profile: evaluation of psychometric properties and comparison of Rasch and summated Likert-scaling","volume":"46","author":"Garamendi","year":"2006","journal-title":"Vision Res"},{"key":"10.1016\/j.ophtha.2012.03.051_bib32","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1001\/archopht.1997.01100150769013","article-title":"Measurements of vision function and quality of life in patients with cataracts in southern India: report of instrument development","volume":"115","author":"Fletcher","year":"1997","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2012.03.051_bib33","doi-asserted-by":"crossref","first-page":"5449","DOI":"10.1167\/iovs.10-6770","article-title":"Refractive error in Nigerian adults: prevalence, type, and spectacle coverage","volume":"52","author":"Ezelum","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2012.03.051_bib34","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1097\/OPX.0b013e3181fef3a9","article-title":"Reported wearing compliance of ready-made spectacles at 6 and 12 months","volume":"87","author":"Vincent","year":"2010","journal-title":"Optom Vis Sci"}],"container-title":["Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0161642012003193?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0161642012003193?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T14:03:09Z","timestamp":1758981789000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0161642012003193"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,10]]},"references-count":34,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2012,10]]}},"alternative-id":["S0161642012003193"],"URL":"https:\/\/doi.org\/10.1016\/j.ophtha.2012.03.051","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.717952669.793458085","asserted-by":"object"}]},"ISSN":["0161-6420"],"issn-type":[{"value":"0161-6420","type":"print"}],"subject":[],"published":{"date-parts":[[2012,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Visual Function after Correction of Distance Refractive Error with Ready-made and Custom Spectacles: A Randomized Clinical Trial","name":"articletitle","label":"Article Title"},{"value":"Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ophtha.2012.03.051","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}