{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T02:22:17Z","timestamp":1789179737919,"version":"build-2803163510"},"reference-count":45,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2020,11,1]],"date-time":"2020-11-01T00:00:00Z","timestamp":1604188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,11,1]],"date-time":"2020-11-01T00:00:00Z","timestamp":1604188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100008377","name":"Handok","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008377","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["aaojournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmology"],"published-print":{"date-parts":[[2020,11]]},"DOI":"10.1016\/j.ophtha.2020.05.010","type":"journal-article","created":{"date-parts":[[2020,5,15]],"date-time":"2020-05-15T18:52:57Z","timestamp":1589568777000},"page":"1487-1497","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":33,"title":["Twenty-four\u2013Hour Intraocular Pressure\u2013Related Patterns from Contact Lens Sensors in Normal-Tension Glaucoma and Healthy Eyes"],"prefix":"10.1016","volume":"127","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4784-0341","authenticated-orcid":false,"given":"Yong Woo","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2393-5346","authenticated-orcid":false,"given":"Jin-Soo","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang Yoon","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahnul","family":"Ha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3122-9652","authenticated-orcid":false,"given":"Jinho","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Joo","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Kook","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1690-1239","authenticated-orcid":false,"given":"Jin Wook","family":"Jeoung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8137-8843","authenticated-orcid":false,"given":"Ki Ho","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ophtha.2020.05.010_bib1","doi-asserted-by":"crossref","first-page":"1268","DOI":"10.1001\/archopht.120.10.1268","article-title":"Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial","volume":"120","author":"Heijl","year":"2002","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib2","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1001\/archopht.120.6.701","article-title":"The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma","volume":"120","author":"Kass","year":"2002","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib3","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1016\/S0002-9394(98)00223-2","article-title":"Comparison of glaucomatous progression between untreated patients with normal-tension glaucoma and patients with therapeutically reduced intraocular pressures. Collaborative Normal-Tension Glaucoma Study Group","volume":"126","year":"1998","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib4","doi-asserted-by":"crossref","first-page":"1209","DOI":"10.1136\/bjophthalmol-2018-313381","article-title":"Exogenous influences on intraocular pressure","volume":"103","author":"Kim","year":"2019","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib5","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1136\/bjo.2010.192922","article-title":"Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma","volume":"95","author":"Mansouri","year":"2011","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib6","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1001\/jamaophthalmol.2013.5297","article-title":"24-hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor","volume":"131","author":"Mottet","year":"2013","journal-title":"JAMA Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib7","doi-asserted-by":"crossref","first-page":"1534","DOI":"10.1001\/archophthalmol.2012.2280","article-title":"Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma","volume":"130","author":"Mansouri","year":"2012","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib8","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/IJG.0000000000000517","article-title":"The fluctuation of intraocular pressure measured by a contact lens sensor in normal-tension glaucoma patients and nonglaucoma subjects","volume":"26","author":"Tojo","year":"2017","journal-title":"J\u00a0Glaucoma"},{"key":"10.1016\/j.ophtha.2020.05.010_bib9","doi-asserted-by":"crossref","first-page":"e463","DOI":"10.1097\/IJG.0000000000000292","article-title":"Fluctuations of the intraocular pressure in pseudoexfoliation syndrome and normal eyes measured by a contact lens sensor","volume":"25","author":"Tojo","year":"2016","journal-title":"J\u00a0Glaucoma"},{"key":"10.1016\/j.ophtha.2020.05.010_bib10","doi-asserted-by":"crossref","first-page":"e14","DOI":"10.1111\/aos.12408","article-title":"Circadian intraocular pressure patterns in healthy subjects, primary open angle and normal tension glaucoma patients with a contact lens sensor","volume":"93","author":"Agnifili","year":"2015","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib11","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.preteyeres.2016.07.002","article-title":"24-h monitoring devices and nyctohemeral rhythms of intraocular pressure","volume":"55","author":"Aptel","year":"2016","journal-title":"Prog Retin Eye Res"},{"key":"10.1016\/j.ophtha.2020.05.010_bib12","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1016\/j.jcjo.2014.07.008","article-title":"Intraocular pressure variations: causes and clinical significance","volume":"49","author":"Sit","year":"2014","journal-title":"Can J Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib13","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/S0079-6123(08)64566-5","article-title":"The fourth C.U. Ariens Kappers lecture. The organization of the human circadian timing system","volume":"93","author":"Moore","year":"1992","journal-title":"Prog Brain Res"},{"key":"10.1016\/j.ophtha.2020.05.010_bib14","doi-asserted-by":"crossref","first-page":"1162","DOI":"10.1001\/archophthalmol.2011.226","article-title":"Aqueous humor dynamics during the day and night in volunteers with ocular hypertension","volume":"129","author":"Fan","year":"2011","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib15","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1001\/archophthalmol.2011.4","article-title":"Aqueous humor dynamics during the day and night in healthy mature volunteers","volume":"129","author":"Liu","year":"2011","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib16","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1016\/j.ophtha.2011.11.024","article-title":"Effect of head and body position on intraocular pressure","volume":"119","author":"Malihi","year":"2012","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2020.05.010_bib17","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/j.ajo.2012.08.003","article-title":"The effect of lateral decubitus position on intraocular pressure in patients with untreated open-angle glaucoma","volume":"155","author":"Lee","year":"2013","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib18","doi-asserted-by":"crossref","first-page":"1565","DOI":"10.1016\/j.ophtha.2013.01.011","article-title":"Effects of different sleeping postures on intraocular pressure and ocular perfusion pressure in healthy young subjects","volume":"120","author":"Lee","year":"2013","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2020.05.010_bib19","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/0002-9394(75)90792-8","article-title":"Diurnal variation of intraocular pressure in primary open-angle glaucoma","volume":"79","author":"Kitazawa","year":"1975","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib20","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1001\/archopht.1997.01100150184006","article-title":"Diurnal intraocular pressure in untreated exfoliation and primary open-angle glaucoma","volume":"115","author":"Konstas","year":"1997","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib21","first-page":"139","article-title":"Twenty-four-hour time course of intraocular pressure in healthy and glaucomatous Africans: relation to sleep patterns","volume":"108","author":"Noel","year":"2001","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2020.05.010_bib22","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1167\/iovs.09-3668","article-title":"Twenty-four hour (Nyctohemeral) rhythm of intraocular pressure and ocular perfusion pressure in normal-tension glaucoma","volume":"51","author":"Renard","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2020.05.010_bib23","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1001\/archopht.121.4.453","article-title":"The effect of latanoprost, brimonidine, and a fixed combination of timolol and dorzolamide on circadian intraocular pressure in patients with glaucoma or ocular hypertension","volume":"121","author":"Orzalesi","year":"2003","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib24","doi-asserted-by":"crossref","first-page":"2209","DOI":"10.1167\/iovs.08-2889","article-title":"The circadian curve of intraocular pressure: can we estimate its characteristics during office hours?","volume":"50","author":"Fogagnolo","year":"2009","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2020.05.010_bib25","doi-asserted-by":"crossref","first-page":"7398","DOI":"10.1167\/iovs.14-14464","article-title":"Asymmetry of habitual 24-hour intraocular pressure rhythm in glaucoma patients","volume":"55","author":"Liu","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2020.05.010_bib26","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1136\/bjo.67.6.362","article-title":"Ocular hypertension and posture","volume":"67","author":"Leonard","year":"1983","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib27","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1097\/00061198-200308000-00015","article-title":"Relationship between postural change of the intraocular pressure and visual field loss in primary open-angle glaucoma","volume":"12","author":"Hirooka","year":"2003","journal-title":"J\u00a0Glaucoma"},{"key":"10.1016\/j.ophtha.2020.05.010_bib28","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1167\/iovs.12-10709","article-title":"Twenty-four-hour pattern of intraocular pressure in untreated patients with ocular hypertension","volume":"54","author":"Grippo","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2020.05.010_bib29","doi-asserted-by":"crossref","first-page":"e68","DOI":"10.1111\/j.1755-3768.2011.02208.x","article-title":"The effect of lateral decubitus position on intraocular pressure in healthy young subjects","volume":"90","author":"Lee","year":"2012","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib30","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/j.ophtha.2012.09.021","article-title":"Effect of lateral decubitus position on intraocular pressure in glaucoma patients with asymmetric visual field loss","volume":"120","author":"Kim","year":"2013","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2020.05.010_bib31","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1097\/OPX.0000000000001322","article-title":"Intraocular pressure elevation during lateral body posture in side-sleeping glaucoma patients","volume":"96","author":"Park","year":"2019","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ophtha.2020.05.010_bib32","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1167\/iovs.11-8763","article-title":"Effects of aging on 24-hour intraocular pressure measurements in sitting and supine body positions","volume":"53","author":"Mansouri","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.ophtha.2020.05.010_bib33","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1016\/S0161-6420(00)00138-X","article-title":"Vascular risk factors for primary open angle glaucoma: the Egna-Neumarkt Study","volume":"107","author":"Bonomi","year":"2000","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2020.05.010_bib34","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1097\/00061198-200408000-00010","article-title":"Open-angle glaucoma and systemic hypertension: the blue mountains eye study","volume":"13","author":"Mitchell","year":"2004","journal-title":"J\u00a0Glaucoma"},{"key":"10.1016\/j.ophtha.2020.05.010_bib35","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1136\/bjo.2004.048710","article-title":"Intraocular pressure and systemic blood pressure: longitudinal perspective: the Beaver Dam Eye Study","volume":"89","author":"Klein","year":"2005","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib36","first-page":"1090","article-title":"Relationship between intraocular pressure and primary open angle glaucoma among white and black Americans","volume":"109","author":"Sommer","year":"1991","journal-title":"The Baltimore Eye Survey. Arch Ophthalmol."},{"key":"10.1016\/j.ophtha.2020.05.010_bib37","doi-asserted-by":"crossref","first-page":"2004","DOI":"10.1016\/j.ophtha.2014.04.016","article-title":"Nocturnal systemic hypotension increases the risk of glaucoma progression","volume":"121","author":"Charlson","year":"2014","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ophtha.2020.05.010_bib38","doi-asserted-by":"crossref","first-page":"e534","DOI":"10.1111\/j.1755-3768.2012.02495.x","article-title":"Corneal thickness after overnight wear of an intraocular pressure fluctuation contact lens sensor","volume":"90","author":"Freiberg","year":"2012","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib39","doi-asserted-by":"crossref","first-page":"e119","DOI":"10.1111\/aos.12241","article-title":"Effect of overnight wear of the Triggerfish((R)) sensor on corneal thickness measured by Visante((R)) anterior segment optical coherence tomography","volume":"92","author":"Hubanova","year":"2014","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib40","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1097\/IJG.0b013e31829e5635","article-title":"Evaluation of continuous 24-hour intraocular pressure monitoring for assessment of prostaglandin-induced pressure reduction in glaucoma","volume":"23","author":"Hollo","year":"2014","journal-title":"J\u00a0Glaucoma"},{"key":"10.1016\/j.ophtha.2020.05.010_bib41","doi-asserted-by":"crossref","first-page":"e414","DOI":"10.1111\/aos.12455","article-title":"Assessment of the Triggerfish contact lens sensor for measurement of intraocular pressure variations","volume":"92","author":"Sunaric-Megevand","year":"2014","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib42","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1136\/bjophthalmol-2016-308710","article-title":"Twenty-four hour intraocular pressure monitoring with the SENSIMED Triggerfish contact lens: effect of body posture during sleep","volume":"101","author":"Beltran-Agullo","year":"2017","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib43","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1016\/j.ajo.2015.07.030","article-title":"Effect of different head positions in lateral decubitus posture on intraocular pressure in treated patients with open-angle glaucoma","volume":"160","author":"Lee","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.ophtha.2020.05.010_bib44","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1097\/OPX.0000000000000432","article-title":"Head position and intraocular pressure in the lateral decubitus position","volume":"92","author":"Seo","year":"2015","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.ophtha.2020.05.010_bib45","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1097\/OPX.0000000000000895","article-title":"Head elevation and intraocular pressure in glaucoma","volume":"93","author":"Park","year":"2016","journal-title":"Optom Vis Sci"}],"container-title":["Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0161642020304486?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0161642020304486?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T14:08:50Z","timestamp":1758982130000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0161642020304486"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11]]},"references-count":45,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2020,11]]}},"alternative-id":["S0161642020304486"],"URL":"https:\/\/doi.org\/10.1016\/j.ophtha.2020.05.010","relation":{},"ISSN":["0161-6420"],"issn-type":[{"value":"0161-6420","type":"print"}],"subject":[],"published":{"date-parts":[[2020,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Twenty-four\u2013Hour Intraocular Pressure\u2013Related Patterns from Contact Lens Sensors in Normal-Tension Glaucoma and Healthy Eyes","name":"articletitle","label":"Article Title"},{"value":"Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ophtha.2020.05.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 by the American Academy of Ophthalmology","name":"copyright","label":"Copyright"}]}}