{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T16:28:17Z","timestamp":1761841697378,"version":"build-2065373602"},"reference-count":44,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,10,3]],"date-time":"2022-10-03T00:00:00Z","timestamp":1664755200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100009740","name":"SUNY Downstate Medical Center","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100009740","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100020963","name":"Department of Epidemiology and Biostatistics, University of California, San Francisco","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100020963","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.es","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Optometry"],"published-print":{"date-parts":[[2023,10]]},"DOI":"10.1016\/j.optom.2022.09.006","type":"journal-article","created":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T02:41:00Z","timestamp":1668566460000},"page":"268-276","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Validation of the DYOP visual acuity test"],"prefix":"10.1016","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9604-3528","authenticated-orcid":false,"given":"Liat","family":"Gantz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dinah","family":"Paritzky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Inbar","family":"Wunch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew H.","family":"Kageyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nadav","family":"Wolf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christina","family":"Cherny","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2744-6358","authenticated-orcid":false,"given":"Mark","family":"Rosenfield","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"10","key":"10.1016\/j.optom.2022.09.006_bib0001","doi-asserted-by":"crossref","first-page":"4321","DOI":"10.1167\/iovs.07-0511","article-title":"Uniformity of visual acuity measures in published studies","volume":"49","author":"Williams","year":"2008","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"Pt 3","key":"10.1016\/j.optom.2022.09.006_bib0002","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1038\/eye.1997.87","article-title":"Visual acuity scored by the letter-by-letter or probit methods has lower retest variability than the line assignment method","volume":"11","author":"Vanden Bosch","year":"1997","journal-title":"Eye"},{"issue":"1","key":"10.1016\/j.optom.2022.09.006_bib0003","first-page":"120","article-title":"On the statistical reliability of letter-chart visual acuity measurements","volume":"34","author":"Arditi","year":"1993","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"5","key":"10.1016\/j.optom.2022.09.006_bib0004","doi-asserted-by":"crossref","first-page":"285.E281","DOI":"10.1016\/j.jaapos.2021.04.009","article-title":"The dynamic optotype (Dyop): a novel visual acuity test for use in children","volume":"25","author":"Barnett-Itzhaki","year":"2021","journal-title":"J AAPOS"},{"key":"10.1016\/j.optom.2022.09.006_bib0005","article-title":"Dynamic visual acuity and methods of measurement","author":"Erdinest","year":"2021","journal-title":"J Optom"},{"issue":"7","key":"10.1016\/j.optom.2022.09.006_bib0006","article-title":"Validation of the Dyop\u2122 visual acuity test","volume":"56","author":"Harris","year":"2015","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"10.1016\/j.optom.2022.09.006_bib0007","series-title":"Paper presented at: American Academy of Optometry Annual Meeting","article-title":"Comparison of subjective refraction findings with Dyop\u00ae acuity chart and LogMAR E Chart","author":"Sum","year":"2017"},{"issue":"4","key":"10.1016\/j.optom.2022.09.006_bib0008","first-page":"202","article-title":"Subjective comparison between DYOP\u00ae and Snellen Refractions","volume":"8","author":"Odjimogho","year":"2020","journal-title":"Optom Vis Perform"},{"issue":"2","key":"10.1016\/j.optom.2022.09.006_bib0009","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1177\/096228029900800204","article-title":"Measuring agreement in method comparison studies","volume":"8","author":"Bland","year":"1999","journal-title":"Stat Methods Med Res"},{"issue":"8476","key":"10.1016\/j.optom.2022.09.006_bib0010","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"issue":"2","key":"10.1016\/j.optom.2022.09.006_bib0011","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1111\/opo.12360","article-title":"What is the appropriate gold standard test for refractive error?","volume":"37","author":"Elliott","year":"2017","journal-title":"Ophthalmic Physiol Opt"},{"issue":"11","key":"10.1016\/j.optom.2022.09.006_bib0012","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1167\/11.11.748","article-title":"Visual acuity with a motion detection target compared to Landolt Rings","volume":"11","author":"Hayes","year":"2011","journal-title":"J Vis"},{"issue":"6","key":"10.1016\/j.optom.2022.09.006_bib0013","first-page":"534","article-title":"Comparison of distance visual acuity measurement between dynamic optotype and logMAR E charts","volume":"39","author":"Sum","year":"2021","journal-title":"Zhonghua Shiyan Yanke Zazhi\/Chin J Exp Ophthalmol"},{"issue":"9","key":"10.1016\/j.optom.2022.09.006_bib0014","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1097\/01.opx.0000144747.88341.b2","article-title":"Screening for myopia and refractive errors using LogMAR visual acuity by optometrists and a simplified visual acuity chart by nurses","volume":"81","author":"Tong","year":"2004","journal-title":"Optom Vis Sci"},{"year":"1989","series-title":"Clinical Visual Optics","author":"Bennett","key":"10.1016\/j.optom.2022.09.006_bib0015"},{"issue":"7","key":"10.1016\/j.optom.2022.09.006_bib0016","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1016\/0002-9394(46)92165-4","article-title":"Unaided visual acuities correlated with refractive errors: a study","volume":"29","author":"Pincus","year":"1946","journal-title":"Am J Ophthalmol"},{"issue":"7","key":"10.1016\/j.optom.2022.09.006_bib0017","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/00006324-195607000-00003","article-title":"The effect of errors of refraction on visual acuity","volume":"33","author":"Prince","year":"1956","journal-title":"Optom Vis Sci"},{"issue":"4","key":"10.1016\/j.optom.2022.09.006_bib0018","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1097\/00006324-196104000-00002","article-title":"The relationship between refractive error and visual acuity at three age levels","volume":"38","author":"Peters","year":"1961","journal-title":"Optom Vis Sci"},{"issue":"3","key":"10.1016\/j.optom.2022.09.006_bib0019","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.optom.2016.07.003","article-title":"Influence of different types of astigmatism on visual acuity","volume":"10","author":"Remon","year":"2017","journal-title":"J Optom"},{"issue":"12","key":"10.1016\/j.optom.2022.09.006_bib0020","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1097\/00006324-199512000-00004","article-title":"Effects of luminance, contrast, and blur on visual acuity","volume":"72","author":"Johnson","year":"1995","journal-title":"Optom Vis Sci"},{"issue":"12","key":"10.1016\/j.optom.2022.09.006_bib0021","doi-asserted-by":"crossref","first-page":"2598","DOI":"10.1016\/j.jcrs.2015.06.029","article-title":"Precision (repeatability and reproducibility) studies and sample-size calculation","volume":"41","author":"McAlinden","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"10.1016\/j.optom.2022.09.006_bib0022","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1097\/00006324-199805000-00024","article-title":"Repeatability of visual acuity measurement","volume":"75","author":"Raasch","year":"1998","journal-title":"Optom Vis Sci"},{"issue":"4","key":"10.1016\/j.optom.2022.09.006_bib0023","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1111\/j.1475-1313.2011.00851.x","article-title":"Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology","volume":"31","author":"McAlinden","year":"2011","journal-title":"Ophthalmic Physiol Opt"},{"issue":"3","key":"10.1016\/j.optom.2022.09.006_bib0024","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1097\/OPX.0000000000001185","article-title":"Repeatability of monocular acuity testing in adults with and without down syndrome","volume":"95","author":"Ravikumar","year":"2018","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.optom.2022.09.006_bib0025","first-page":"311","article-title":"Prospective evaluation of visual acuity assessment: a comparison of snellen versus ETDRS charts in clinical practice (An AOS Thesis)","volume":"107","author":"Kaiser","year":"2009","journal-title":"Trans Am Ophthalmol Soc"},{"key":"10.1016\/j.optom.2022.09.006_bib0026","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.visres.2013.07.010","article-title":"Testing vision: from laboratory psychophysical tests to clinical evaluation","volume":"90","author":"Chung","year":"2013","journal-title":"Vision Res"},{"issue":"5","key":"10.1016\/j.optom.2022.09.006_bib0027","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1007\/s00417-014-2876-z","article-title":"Repeatability of mesopic visual acuity measurements using high-and low-contrast ETDRS letter charts","volume":"253","author":"Barrio","year":"2015","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"10.1016\/j.optom.2022.09.006_bib0028","first-page":"23","article-title":"The relationship between dynamic visual acuity and saccadic eye movement","volume":"5","author":"Kohmura","year":"2008","journal-title":"Hum Perform Meas"},{"issue":"6","key":"10.1016\/j.optom.2022.09.006_bib0029","first-page":"460","article-title":"Dynamic acuity a quantitative measure of eye movements","volume":"38","author":"Kirshner","year":"1967","journal-title":"Optom- J Am Optom A"},{"key":"10.1016\/j.optom.2022.09.006_bib0030","doi-asserted-by":"crossref","first-page":"93","DOI":"10.2147\/OPTO.S166786","article-title":"The effect of astigmatic axis on visual acuity measured with different alphabets in Roman alphabet readers","volume":"10","author":"Serra","year":"2018","journal-title":"Clin Optom (Auckl)"},{"issue":"3","key":"10.1016\/j.optom.2022.09.006_bib0031","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1016\/j.jcrs.2010.09.022","article-title":"Effect of uncorrected astigmatism on vision","volume":"37","author":"Wolffsohn","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.optom.2022.09.006_bib0032","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1097\/00006324-194505000-00002","article-title":"On astigmatism. Part III\u2014subjective tests","volume":"22","author":"Bannon","year":"1945","journal-title":"Am J Optom Arch Am Acad Optom"},{"issue":"1","key":"10.1016\/j.optom.2022.09.006_bib0033","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1136\/bjo.27.1.1","article-title":"A possible fallacy in the use of the cross-cylinder","volume":"27","author":"Williamson-Noble","year":"1943","journal-title":"Br J Ophthalmol"},{"issue":"6","key":"10.1016\/j.optom.2022.09.006_bib0034","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1097\/00006324-200206000-00013","article-title":"The effects of optical defocus on the legibility of the Tumbling-E and Landolt-C","volume":"79","author":"Reich","year":"2002","journal-title":"Optom Vis Sci"},{"issue":"3","key":"10.1016\/j.optom.2022.09.006_bib0035","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/S0304-3940(01)01505-1","article-title":"The visual resolution of Landolt-C optotypes in human subjects depends on their orientation: the 'gap-down' effect","volume":"299","author":"Schrauf","year":"2001","journal-title":"Neurosci Lett"},{"key":"10.1016\/j.optom.2022.09.006_bib0036","doi-asserted-by":"crossref","first-page":"28","DOI":"10.3389\/fnhum.2012.00028","article-title":"Global versus local processing: seeing the left side of the forest and the right side of the trees","volume":"6","author":"Christie","year":"2012","journal-title":"Front Hum Neurosci"},{"issue":"7","key":"10.1016\/j.optom.2022.09.006_bib0037","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1097\/00006324-195207000-00009","article-title":"Changes in corneal astigmatism","volume":"29","author":"Phillips","year":"1952","journal-title":"Am J Optom Arch Am Acad Optom"},{"issue":"7","key":"10.1016\/j.optom.2022.09.006_bib0038","doi-asserted-by":"crossref","first-page":"E798","DOI":"10.1097\/OPX.0b013e3182186bc4","article-title":"Visual acuity with astigmatic blur","volume":"88","author":"Atchison","year":"2011","journal-title":"Optom Vis Sci"},{"issue":"7","key":"10.1016\/j.optom.2022.09.006_bib0039","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1097\/00006324-199307000-00002","article-title":"Decreased uncorrected vision after a period of distance fixation with spectacle wear","volume":"70","author":"Pesudovs","year":"1993","journal-title":"Optom Vis Sci"},{"issue":"1390","key":"10.1016\/j.optom.2022.09.006_bib0040","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1098\/rspb.1998.0266","article-title":"Improving vision: neural compensation for optical defocus","volume":"265","author":"Mon-Williams","year":"1998","journal-title":"Proc Biol Sci"},{"issue":"9","key":"10.1016\/j.optom.2022.09.006_bib0041","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1097\/01.opx.0000144743.34976.da","article-title":"Blur adaptation in myopes","volume":"81","author":"Rosenfield","year":"2004","journal-title":"Optom Vis Sci"},{"issue":"5","key":"10.1016\/j.optom.2022.09.006_bib0042","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1097\/OPX.0b013e31821281bc","article-title":"Visual acuity with simulated and real astigmatic defocus","volume":"88","author":"Ohlendorf","year":"2011","journal-title":"Optom Vis Sci"},{"issue":"12","key":"10.1016\/j.optom.2022.09.006_bib0043","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1167\/10.12.22","article-title":"Adaptation to astigmatic blur","volume":"10","author":"Sawides","year":"2010","journal-title":"J Vis"},{"issue":"6","key":"10.1016\/j.optom.2022.09.006_bib0044","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.visres.2011.01.010","article-title":"Neuronal adaptation to simulated and optically-induced astigmatic defocus","volume":"51","author":"Ohlendorf","year":"2011","journal-title":"Vision Res"}],"container-title":["Journal of Optometry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1888429622000656?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1888429622000656?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T11:13:20Z","timestamp":1761822800000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1888429622000656"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10]]},"references-count":44,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,10]]}},"alternative-id":["S1888429622000656"],"URL":"https:\/\/doi.org\/10.1016\/j.optom.2022.09.006","relation":{},"ISSN":["1888-4296"],"issn-type":[{"type":"print","value":"1888-4296"}],"subject":[],"published":{"date-parts":[[2023,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Validation of the DYOP visual acuity test","name":"articletitle","label":"Article Title"},{"value":"Journal of Optometry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.optom.2022.09.006","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 Spanish General Council of Optometry. Published by Elsevier Espa\u00f1a, S.L.U.","name":"copyright","label":"Copyright"}]}}