{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T11:10:26Z","timestamp":1767611426328},"reference-count":38,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","theclinics.com","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Otolaryngologic Clinics of North America"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1016\/j.otc.2019.09.013","type":"journal-article","created":{"date-parts":[[2019,11,1]],"date-time":"2019-11-01T22:34:01Z","timestamp":1572647641000},"page":"57-71","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Special Considerations in Patients with Cranial Neurostimulatory Implants"],"prefix":"10.1016","volume":"53","author":[{"given":"Johanna L.","family":"Wickemeyer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeffrey D.","family":"Sharon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heather M.","family":"Weinreich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.otc.2019.09.013_bib1","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1002\/lary.27516","article-title":"Magnetic resonance imaging with cochlear implants and auditory brainstem implants: are we truly practicing MRI safety?","volume":"129","author":"Shew","year":"2019","journal-title":"Laryngoscope"},{"issue":"3","key":"10.1016\/j.otc.2019.09.013_bib2","first-page":"311","article-title":"MRI compatibility and safety of cochlear implants","volume":"37","author":"Tang","year":"2012","journal-title":"Zhong Nan Da Xue Xue Bao Yi Xue Ban"},{"issue":"11","key":"10.1016\/j.otc.2019.09.013_bib3","doi-asserted-by":"crossref","first-page":"1967","DOI":"10.1002\/ar.22580","article-title":"The cochlear implant: historical aspects and future prospects","volume":"295","author":"Eshraghi","year":"2012","journal-title":"Anat Rec (Hoboken)"},{"issue":"4","key":"10.1016\/j.otc.2019.09.013_bib5","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1111\/j.1540-8159.2005.50024.x","article-title":"Current clinical issues for MRI scanning of pacemaker and defibrillator patients","volume":"28","author":"Kalin","year":"2005","journal-title":"Pacing Clin Electrophysiol"},{"issue":"5","key":"10.1016\/j.otc.2019.09.013_bib6","first-page":"724","article-title":"Evaluation of MRI compatibility of the modified nucleus multichannel auditory brainstem and cochlear implants","volume":"17","author":"Heller","year":"1996","journal-title":"Am J Otol"},{"issue":"5","key":"10.1016\/j.otc.2019.09.013_bib7","first-page":"584","article-title":"Magnetic resonance imaging compatibility testing of the clarion 1.2 cochlear implant","volume":"19","author":"Weber","year":"1998","journal-title":"Am J Otol"},{"issue":"1","key":"10.1016\/j.otc.2019.09.013_bib8","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1002\/(SICI)1522-2586(199901)9:1<26::AID-JMRI4>3.0.CO;2-H","article-title":"Magnetic resonance imaging and cochlear implants: compatibility and safety aspects","volume":"9","author":"Teissl","year":"1999","journal-title":"J\u00a0Magn Reson Imaging"},{"issue":"4","key":"10.1016\/j.otc.2019.09.013_bib9","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1177\/0194599813518306","article-title":"MRI information for commonly used otologic implants: review and update","volume":"150","author":"Azadarmaki","year":"2014","journal-title":"Otolaryngol Head Neck Surg"},{"issue":"2","key":"10.1016\/j.otc.2019.09.013_bib10","doi-asserted-by":"crossref","first-page":"e80","DOI":"10.1097\/MAO.0000000000001661","article-title":"A\u00a0prospective study of pain from magnetic resonance imaging with cochlear implant magnets in\u00a0situ","volume":"39","author":"Pross","year":"2018","journal-title":"Otol Neurotol"},{"issue":"8","key":"10.1016\/j.otc.2019.09.013_bib11","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1097\/MAO.0b013e3181ec1d61","article-title":"Magnetic resonance imaging at 1.5\u00a0T after cochlear implantation","volume":"31","author":"Crane","year":"2010","journal-title":"Otol Neurotol"},{"issue":"5","key":"10.1016\/j.otc.2019.09.013_bib12","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1097\/MAO.0000000000000330","article-title":"MRI without magnet removal in neurofibromatosis type 2 patients with cochlear and auditory brainstem implants","volume":"35","author":"Walton","year":"2014","journal-title":"Otol Neurotol"},{"issue":"6","key":"10.1016\/j.otc.2019.09.013_bib13","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1097\/MAO.0000000000000666","article-title":"Magnetic resonance imaging with cochlear implant magnet in place: safety and imaging quality","volume":"36","author":"Carlson","year":"2015","journal-title":"Otol Neurotol"},{"issue":"1","key":"10.1016\/j.otc.2019.09.013_bib14","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1001\/jamaoto.2014.2926","article-title":"Adverse events and discomfort during magnetic resonance imaging in cochlear implant recipients","volume":"141","author":"Kim","year":"2015","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"issue":"Suppl 1","key":"10.1016\/j.otc.2019.09.013_bib15","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s00106-016-0129-7","article-title":"Prevalence and complications of MRI scans of cochlear implant patients: English version","volume":"65","author":"Grupe","year":"2017","journal-title":"HNO"},{"issue":"8","key":"10.1016\/j.otc.2019.09.013_bib16","doi-asserted-by":"crossref","first-page":"674","DOI":"10.6009\/jjrt.2016_JSRT_72.8.674","article-title":"The safety of MR conditional cochlear implant at 1.5 tesla magnetic resonance imaging system","volume":"72","author":"Takahashi","year":"2016","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"issue":"10","key":"10.1016\/j.otc.2019.09.013_bib17","doi-asserted-by":"crossref","first-page":"e401","DOI":"10.1097\/MAO.0000000000001569","article-title":"Pain free 3\u00a0T MRI scans in cochlear implantees","volume":"38","author":"Todt","year":"2017","journal-title":"Otol Neurotol"},{"issue":"Suppl 2","key":"10.1016\/j.otc.2019.09.013_bib18","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1007\/s00106-016-0296-6","article-title":"Postoperative imaging of the internal auditory canal: visualization of active auditory implants","volume":"65","author":"Todt","year":"2017","journal-title":"HNO"},{"issue":"9","key":"10.1016\/j.otc.2019.09.013_bib19","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1097\/MAO.0000000000001176","article-title":"Magnetic resonance imaging at 1.5 tesla with a cochlear implant magnet in place: image quality and usability","volume":"37","author":"Sharon","year":"2016","journal-title":"Otol Neurotol"},{"issue":"1","key":"10.1016\/j.otc.2019.09.013_bib20","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/S0360-3016(98)00532-X","article-title":"Cochlear implants: response to therapeutic irradiation","volume":"44","author":"Ralston","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"5","key":"10.1016\/j.otc.2019.09.013_bib21","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s00405-003-0670-3","article-title":"The effect of large single radiation doses on cochlear implant function: implications for radiosurgery","volume":"261","author":"Klenzner","year":"2004","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"10.1016\/j.otc.2019.09.013_bib22","unstructured":"Advanced Bionics L. INSTRUCTIONS FOR USE HiResolution\u2122 bionic ear system. Manufacturer-provided instructions manual. Personal communication. June 25, 2018."},{"key":"10.1016\/j.otc.2019.09.013_bib23","author":"MED-EL"},{"key":"10.1016\/j.otc.2019.09.013_bib24","series-title":"Cochlear","author":"Manning","year":"2019"},{"key":"10.1016\/j.otc.2019.09.013_bib25","series-title":"Programmable CSF shunts and magnetic field interference with implanted hearing devices - letter to health care providers","author":"Maisel","year":"2019"},{"issue":"6","key":"10.1016\/j.otc.2019.09.013_bib26","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1097\/MAO.0b013e3181b04e3b","article-title":"Cochlear implantation in the presence of a programmable ventriculoperitoneal shunt","volume":"30","author":"Wiet","year":"2009","journal-title":"Otol Neurotol"},{"issue":"12","key":"10.1016\/j.otc.2019.09.013_bib27","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s00701-011-1180-5","article-title":"Cochlear implantation for total deafness after ipsilateral ventriculoperitoneal shunt surgery: technical report","volume":"153","author":"An","year":"2011","journal-title":"Acta Neurochir (Wien)"},{"issue":"9 Pt 1","key":"10.1016\/j.otc.2019.09.013_bib28","doi-asserted-by":"crossref","first-page":"1184","DOI":"10.1097\/00005537-199609000-00026","article-title":"Cochlear implantation in a pacemaker patient","volume":"106","author":"Triglia","year":"1996","journal-title":"Laryngoscope"},{"issue":"2","key":"10.1016\/j.otc.2019.09.013_bib29","doi-asserted-by":"crossref","first-page":"208","DOI":"10.5152\/balkanmedj.2015.15937","article-title":"Cochlear implantation in extraordinary cases","volume":"32","author":"Celenk","year":"2015","journal-title":"Balkan Med J"},{"issue":"1","key":"10.1016\/j.otc.2019.09.013_bib30","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1097\/01.mlg.0000245943.95695.65","article-title":"Cochlear implantation in a patient with bilateral deep brain stimulators","volume":"117","author":"St Martin","year":"2007","journal-title":"Laryngoscope"},{"issue":"1","key":"10.1016\/j.otc.2019.09.013_bib31","first-page":"e12","article-title":"Magnetic resonance imaging in a neurofibromatosis type 2 patient with a novel MRI-compatible auditory brainstem implant","volume":"78","author":"Shew","year":"2017","journal-title":"J\u00a0Neurol Surg Rep"},{"issue":"5","key":"10.1016\/j.otc.2019.09.013_bib32","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1002\/lary.25032","article-title":"Hypoglossal nerve stimulation in the treatment of obstructive sleep apnea: a systematic review and meta-analysis","volume":"125","author":"Certal","year":"2015","journal-title":"Laryngoscope"},{"issue":"8","key":"10.1016\/j.otc.2019.09.013_bib34","doi-asserted-by":"crossref","first-page":"1949","DOI":"10.1002\/lary.27488","article-title":"Dysfunctional hypoglossal nerve stimulator after electrical cardioversion: a case series","volume":"129","author":"Vasconcellos","year":"2019","journal-title":"Laryngoscope"},{"issue":"4","key":"10.1016\/j.otc.2019.09.013_bib35","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/j.amjoto.2018.04.006","article-title":"Electroconvulsive therapy for depression in a patient with an inspire hypoglossal nerve stimulator device for obstructive sleep apnea: a case report","volume":"39","author":"Mingo","year":"2018","journal-title":"Am J Otolaryngol"},{"issue":"3","key":"10.1016\/j.otc.2019.09.013_bib36","first-page":"175","article-title":"Electrical stimulation and monitoring devices of the CNS: an imaging review","volume":"44","author":"Patel","year":"2017","journal-title":"J\u00a0Neuroradiol"},{"issue":"1","key":"10.1016\/j.otc.2019.09.013_bib37","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1016\/j.ejpn.2016.06.001","article-title":"Technical challenges and safety of magnetic resonance imaging with in\u00a0situ neuromodulation from spine to brain","volume":"21","author":"Thornton","year":"2017","journal-title":"Eur J Paediatr Neurol"},{"key":"10.1016\/j.otc.2019.09.013_bib38","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.eplepsyres.2014.11.010","article-title":"3T-MRI in patients with pharmacoresistant epilepsy and a vagus nerve stimulator: a pilot study","volume":"110","author":"Rosch","year":"2015","journal-title":"Epilepsy Res"},{"key":"10.1016\/j.otc.2019.09.013_bib39","series-title":"Vestibular implants","author":"Della Santina","year":"2019"},{"issue":"2","key":"10.1016\/j.otc.2019.09.013_bib40","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1002\/alr.22237","article-title":"Induction of smell through transethmoid electrical stimulation of the olfactory bulb","volume":"9","author":"Holbrook","year":"2019","journal-title":"Int Forum Allergy Rhinol"}],"container-title":["Otolaryngologic Clinics of North America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S003066651930180X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S003066651930180X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,11,15]],"date-time":"2019-11-15T22:31:41Z","timestamp":1573857101000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S003066651930180X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["S003066651930180X"],"URL":"https:\/\/doi.org\/10.1016\/j.otc.2019.09.013","relation":{},"ISSN":["0030-6665"],"issn-type":[{"value":"0030-6665","type":"print"}],"subject":[],"published":{"date-parts":[[2020,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Special Considerations in Patients with Cranial Neurostimulatory Implants","name":"articletitle","label":"Article Title"},{"value":"Otolaryngologic Clinics of North America","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.otc.2019.09.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}