{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T02:11:32Z","timestamp":1792203092962,"version":"4.4.0"},"reference-count":30,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2011,9,1]],"date-time":"2011-09-01T00:00:00Z","timestamp":1314835200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,9,1]],"date-time":"2011-09-01T00:00:00Z","timestamp":1314835200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2013,7,29]],"date-time":"2013-07-29T00:00:00Z","timestamp":1375056000000},"content-version":"vor","delay-in-days":697,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"published-print":{"date-parts":[[2011,9]]},"DOI":"10.1016\/j.otsr.2010.11.011","type":"journal-article","created":{"date-parts":[[2011,6,20]],"date-time":"2011-06-20T19:57:45Z","timestamp":1308599865000},"page":"471-478","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":35,"title":["Dorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial"],"prefix":"10.1016","volume":"97","author":[{"given":"J.","family":"Chappuis","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Bout\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Putz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.otsr.2010.11.011_bib0005","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1007\/BF01629573","article-title":"Different risk profiles for hip fractures and distal forearm fractures: a prospective study","volume":"6","author":"Graafmans","year":"1996","journal-title":"Osteopor Int"},{"key":"10.1016\/j.otsr.2010.11.011_bib0010","doi-asserted-by":"crossref","first-page":"1956","DOI":"10.2106\/00004623-200310000-00014","article-title":"Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius","volume":"85","author":"Rozental","year":"2003","journal-title":"J Bone Joint Surg (Am)"},{"key":"10.1016\/j.otsr.2010.11.011_bib0015","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.jhsa.2006.02.015","article-title":"Volar fixation of dorsally angulated extra-articular fractures of the distal radius: a biomechanical study","volume":"31 A","author":"Koh","year":"2006","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0020","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1097\/BOT.0b013e318186006f","article-title":"Does a volar locking plate provide equivalent stability as a dorsal non-locking plate in a dorsally comminuted distal radius fracture? A biomechanical study","volume":"22","author":"Kandemir","year":"2008","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.otsr.2010.11.011_bib0025","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1097\/00005131-200503000-00006","article-title":"A biomechanical comparison of a dorsal 3.5mm T-plate and a volar fixed angle plate in a model of dorsally unstable distal radius fractures","volume":"19","author":"Liporace","year":"2005","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.otsr.2010.11.011_bib0030","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1016\/j.jhsa.2007.04.016","article-title":"Volar versus dorsal fixed angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanical study","volume":"32 A","author":"McCall","year":"2007","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0035","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1053\/jhsu.2003.50016","article-title":"Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study","volume":"28A","author":"Osada","year":"2003","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0040","doi-asserted-by":"crossref","first-page":"2411","DOI":"10.2106\/JBJS.E.00946","article-title":"Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate stability","volume":"88","author":"Willis","year":"2006","journal-title":"J Bone Joint Surg (Am)"},{"key":"10.1016\/j.otsr.2010.11.011_bib0045","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1097\/01.bth.0000173374.97406.70","article-title":"Fixed angle fixation of distal radius fracture through a minimally invasive approach","volume":"9","author":"Orbay","year":"2005","journal-title":"Tech Hand Upper Extrem Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0050","series-title":"Fractures du radius distal chez l\u2019adulte","first-page":"137","article-title":"Ost\u00e9osynth\u00e8se par clou-plaque post\u00e9rieur des fractures \u00e0 bascule post\u00e9rieure\u00a0: \u00e9tude prospective \u00e0 propos de 27\u00a0cas","author":"Kaba","year":"2006"},{"key":"10.1016\/j.otsr.2010.11.011_bib0055","doi-asserted-by":"crossref","unstructured":"Frykman G. Fracture of the distal radius including sequelae\u2013shoulder-hand-finger syndrome, disturbance in the distal radio-ulnar joint and impairment of nerve function. Acta Orthop Scand 1967;Suppl. 108:3.","DOI":"10.3109\/ort.1967.38.suppl-108.01"},{"key":"10.1016\/j.otsr.2010.11.011_bib0060","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1002\/(SICI)1097-0274(199606)29:6<602::AID-AJIM4>3.0.CO;2-L","article-title":"Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand)","volume":"29","author":"Hudak","year":"1996","journal-title":"Am J Ind Med"},{"key":"10.1016\/j.otsr.2010.11.011_bib0065","doi-asserted-by":"crossref","first-page":"1706","DOI":"10.1016\/j.jhsa.2008.07.004","article-title":"Intramedullary fixation of displaced distal radius fractures: a preliminary report","volume":"33A","author":"Ilyas","year":"2008","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0070","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1097\/01.blo.0000205892.96575.d4","article-title":"Internal fixation of distal radius fractures with novel intramedullary implants","volume":"445","author":"Brooks","year":"2006","journal-title":"Clin Orthop Rel Res"},{"key":"10.1016\/j.otsr.2010.11.011_bib0075","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/00003086-200204000-00047","article-title":"Palmar plating for dorsally displaced fractures of the distal radius","volume":"397","author":"Kamano","year":"2002","journal-title":"Clin Orthop Rel Res"},{"key":"10.1016\/j.otsr.2010.11.011_bib0080","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.jhsa.2003.09.015","article-title":"Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient","volume":"29A","author":"Orbay","year":"2004","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0085","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/j.jhsa.2005.03.006","article-title":"Volar fixation of dorsally displaced distal radius fractures using the 2.4mm locking compression plates","volume":"30A","author":"Musgarve","year":"2005","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0090","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1177\/230949900501300208","article-title":"Volar fixation of dorsally displaced distal radial fracture using locking compression plate","volume":"13","author":"Wong","year":"2005","journal-title":"J Orthop Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0095","first-page":"663","article-title":"Plate fixation with locking screw for distal fractures of the radius","volume":"92","author":"Cognet","year":"2006","journal-title":"Rev Chir Orthop"},{"key":"10.1016\/j.otsr.2010.11.011_bib0100","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jhsa.2005.10.010","article-title":"Functional outcome and complications after volar plating for dorsally displaced unstable fractures of the distal radius","volume":"31A","author":"Rozental","year":"2006","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0105","first-page":"152","article-title":"Volar fixed angle plate LCP 3.5 for dorsally distal radius fracture. About 24 cases","volume":"94","author":"Pichon","year":"2008","journal-title":"Rev Chir Orthop"},{"key":"10.1016\/j.otsr.2010.11.011_bib0110","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.jhsa.2008.01.024","article-title":"Prospective study of distal radius fractures treated with a volar locking plate system","volume":"33A","author":"Osada","year":"2008","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0115","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1016\/j.jhsa.2008.02.016","article-title":"Comparative outcomes study using the volar locking plating system for distal radius fractures in both young adults and adults older than 60 years","volume":"33A","author":"Chung","year":"2008","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0120","doi-asserted-by":"crossref","first-page":"1610","DOI":"10.1302\/0301-620X.88B12.17696","article-title":"Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures","volume":"88B","author":"Al-Rashid","year":"2006","journal-title":"J Bone Joint Surg (Br)"},{"key":"10.1016\/j.otsr.2010.11.011_bib0125","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1016\/j.jhsa.2007.05.006","article-title":"Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report","volume":"32A","author":"Klug","year":"2007","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0130","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1302\/0301-620X.80B2.0800225","article-title":"Rupture of flexor pollicis longus tendon","volume":"80B","author":"Bell","year":"1998","journal-title":"J Bone Joint Surg (Br)"},{"key":"10.1016\/j.otsr.2010.11.011_bib0135","first-page":"476","article-title":"Rupture de tendons fl\u00e9chisseurs sur plaque ant\u00e9rieure apr\u00e8s fracture du radius distal. \u00c0 propos de 4\u00a0cas et revue de la litt\u00e9rature","volume":"91","author":"Cognet","year":"2005","journal-title":"Rev Chir Orthop"},{"key":"10.1016\/j.otsr.2010.11.011_bib0140","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.jhsa.2007.11.011","article-title":"Flexor tendon injuries following locked volar plating of distal radius fractures","volume":"33A","author":"Cross","year":"2008","journal-title":"J Hand Surg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0145","first-page":"714","article-title":"Complications of volar plating of distal radius fractures","volume":"73","author":"Rampoldi","year":"2007","journal-title":"Acta Orthop Belg"},{"key":"10.1016\/j.otsr.2010.11.011_bib0150","doi-asserted-by":"crossref","first-page":"401","DOI":"10.2106\/JBJS.G.00939","article-title":"Inadvertent retention of angled drill guides after volar locking plate fixation of distal radial fractures. A report of three cases","volume":"90","author":"Bhattacharyya","year":"2008","journal-title":"J Bone Joint Surg (Am)"}],"container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S187705681100096X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S187705681100096X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T03:22:23Z","timestamp":1761794543000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S187705681100096X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,9]]},"references-count":30,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2011,9]]}},"alternative-id":["S187705681100096X"],"URL":"https:\/\/doi.org\/10.1016\/j.otsr.2010.11.011","relation":{},"ISSN":["1877-0568"],"issn-type":[{"value":"1877-0568","type":"print"}],"subject":[],"published":{"date-parts":[[2011,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Dorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial","name":"articletitle","label":"Article Title"},{"value":"Orthopaedics & Traumatology: Surgery & Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.otsr.2010.11.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2011 Elsevier Masson SAS. All rights reserved.","name":"copyright","label":"Copyright"}]}}