{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T04:38:39Z","timestamp":1790743119191,"version":"4.1.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2014,9,1]],"date-time":"2014-09-01T00:00:00Z","timestamp":1409529600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,9,1]],"date-time":"2014-09-01T00:00:00Z","timestamp":1409529600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"published-print":{"date-parts":[[2014,9]]},"DOI":"10.1016\/j.otsr.2014.05.005","type":"journal-article","created":{"date-parts":[[2014,8,5]],"date-time":"2014-08-05T11:41:13Z","timestamp":1407238873000},"page":"461-467","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["The effect of posterior non-fusion instrumentation on segmental shear loading of the lumbar spine"],"prefix":"10.1016","volume":"100","author":[{"given":"Y.P.","family":"Charles","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Persohn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8827-0547","authenticated-orcid":false,"given":"P.","family":"Rouch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0544-7392","authenticated-orcid":false,"given":"J.-P.","family":"Steib","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.A.","family":"Sauleau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W.","family":"Skalli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.otsr.2014.05.005_bib0005","doi-asserted-by":"crossref","first-page":"1550","DOI":"10.1097\/00007632-199807150-00009","article-title":"Stability of posterior spinal instrumentation and its effects on adjacent motion segments in the lumbosacral spine","volume":"23","author":"Shono","year":"1998","journal-title":"Spine"},{"key":"10.1016\/j.otsr.2014.05.005_bib0010","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1097\/01.brs.0000259071.64027.04","article-title":"Total lumbar disc replacement: different results for different levels","volume":"32","author":"Siepe","year":"2007","journal-title":"Spine"},{"key":"10.1016\/j.otsr.2014.05.005_bib0015","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1097\/01.brs.0000200092.49001.6e","article-title":"Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis","volume":"31","author":"Schnake","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.otsr.2014.05.005_bib0020","doi-asserted-by":"crossref","first-page":"2159","DOI":"10.1007\/s00586-007-0444-5","article-title":"StabilimaxNZ\u00ae versus simulated fusion: evaluation of adjacent level effects","volume":"16","author":"Panjabi","year":"2007","journal-title":"Eur Spine J"},{"key":"10.1016\/j.otsr.2014.05.005_bib0025","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1007\/s00586-011-2121-y","article-title":"Biomechanical evaluation of a posterior non-fusion instrumentation of the lumbar spine","volume":"21","author":"Schmoelz","year":"2012","journal-title":"Eur Spine J"},{"key":"10.1016\/j.otsr.2014.05.005_bib0030","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1007\/s00132-009-1588-2","article-title":"Status quo of facet joint replacement","volume":"39","author":"B\u00fcttner-Janz","year":"2010","journal-title":"Orthopade"},{"key":"10.1016\/j.otsr.2014.05.005_bib0035","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1097\/00007632-199011010-00011","article-title":"Biomechanical evaluation of lumbar spinal stability after graded facetectomy","volume":"15","author":"Abumi","year":"1990","journal-title":"Spine"},{"key":"10.1016\/j.otsr.2014.05.005_bib0040","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1109\/TBME.2003.821009","article-title":"The biomechanics of lumbar graded facetectomy under anterior shear load","volume":"51","author":"Teo","year":"2004","journal-title":"IEEE Trans Biomech Eng"},{"key":"10.1016\/j.otsr.2014.05.005_bib0045","doi-asserted-by":"crossref","first-page":"2790","DOI":"10.1097\/01.brs.0000245872.45554.c0","article-title":"Biomechanical evaluation of a new total posterior element replacement system","volume":"31","author":"Wilke","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.otsr.2014.05.005_bib0050","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1097\/01.brs.0000250983.91339.9f","article-title":"Biomechanical evaluation of the Total Facet Arthroplasty System: 3-dimensional kinematics","volume":"32","author":"Zhu","year":"2007","journal-title":"Spine"},{"key":"10.1016\/j.otsr.2014.05.005_bib0055","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.spinee.2008.01.010","article-title":"Effects of the Total Facet Arthroplasty System after complete laminectomy-facetectomy on the biomechanics of implanted and adjacent segments","volume":"9","author":"Phillips","year":"2009","journal-title":"Spine J"},{"key":"10.1016\/j.otsr.2014.05.005_bib0060","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/S1935-9810(07)70046-4","article-title":"Anatomic Facet Replacement System (AFRS) restoration of lumbar segment mechanics to intact: a finite element study and in vitro cadaver investigation","volume":"1","author":"Goel","year":"2007","journal-title":"SAS J"},{"key":"10.1016\/j.otsr.2014.05.005_bib0065","doi-asserted-by":"crossref","first-page":"E13","DOI":"10.3171\/foc.2007.22.1.13","article-title":"Treatment of lumbar spinal stenosis with a total posterior arthroplasty prosthesis: implant description, surgical technique, and a prospective report on 29 patients","volume":"22","author":"McAfee","year":"2007","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.otsr.2014.05.005_bib0070","series-title":"North American Spine Society Pre-Meeting Course","article-title":"The treatment of symptomatic lumbar spinal stenosis with ACADIA\u2122. Clinical outcomes from worldwide cohort","author":"Castellvi","year":"2009"},{"key":"10.1016\/j.otsr.2014.05.005_bib0075","series-title":"Spine Arthroplasty Society Annual Global Symposium","article-title":"ACADIA\u2122 facet arthroplasty pilot study: twelve months follow-up results for 20 patients at four centers","author":"Regan","year":"2009"},{"key":"10.1016\/j.otsr.2014.05.005_bib0080","doi-asserted-by":"crossref","first-page":"e15","DOI":"10.1016\/j.spinee.2011.06.002","article-title":"Stem fracture after total facet replacement in the lumbar spine: a report of two cases and review of the literature","volume":"11","author":"Palmer","year":"2011","journal-title":"Spine J"},{"key":"10.1016\/j.otsr.2014.05.005_bib0085","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1097\/BRS.0b013e3181df3ea5","article-title":"Influence of an auxiliary facet system on lumbar spine biomechanics","volume":"36","author":"Charles","year":"2011","journal-title":"Spine"},{"key":"10.1016\/j.otsr.2014.05.005_bib0090","doi-asserted-by":"crossref","first-page":"E1","DOI":"10.3171\/foc.2007.22.1.1","article-title":"Biomechanics of the posterior lumbar articulating elements","volume":"22","author":"Serhan","year":"2007","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.otsr.2014.05.005_bib0095","doi-asserted-by":"crossref","first-page":"E204","DOI":"10.1097\/01.brs.0000158871.14960.30","article-title":"Pure shear properties of lumbar spinal joints and the effect of tissue sectioning on load sharing","volume":"30","author":"Lu","year":"2005","journal-title":"Spine"},{"key":"10.1016\/j.otsr.2014.05.005_bib0100","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1302\/0301-620X.93B5.25520","article-title":"What are reliable radiological indicators of lumbar segmental instability?","volume":"93","author":"Hasegawa","year":"2011","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.otsr.2014.05.005_bib0105","doi-asserted-by":"crossref","first-page":"2130","DOI":"10.1007\/s00586-010-1492-9","article-title":"Anterior shear strength of the porcine lumbar spine after laminectomy and partial facetectomy","volume":"19","author":"van Solinge","year":"2010","journal-title":"Eur Spine J"},{"key":"10.1016\/j.otsr.2014.05.005_bib0110","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1007\/s00586-011-1968-2","article-title":"The impact of bone mineral density and disc degeneration on shear and stiffness of the lumbar spine following laminectomy","volume":"21","author":"Bisshop","year":"2012","journal-title":"Eur Spine J"},{"key":"10.1016\/j.otsr.2014.05.005_bib0115","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.jbiomech.2003.10.003","article-title":"Structural behavior of human lumbar spinal motion segments","volume":"37","author":"Gardner-Morse","year":"2004","journal-title":"J Biomech"},{"key":"10.1016\/j.otsr.2014.05.005_bib0120","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1007\/s00586-010-1620-6","article-title":"The effect of design parameters of dynamic pedicle screw systems on kinematics and load bearing: an in vitro study","volume":"20","author":"Schilling","year":"2011","journal-title":"Eur Spine J"},{"key":"10.1016\/j.otsr.2014.05.005_bib0125","doi-asserted-by":"crossref","first-page":"E1126","DOI":"10.1097\/BRS.0b013e31825b528d","article-title":"Load transfer characteristics between posterior spinal implants and the lumbar spine under anterior shear loading: an in vitro investigation","volume":"37","author":"Melnyk","year":"2012","journal-title":"Spine"}],"container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056814001364?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056814001364?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T03:28:22Z","timestamp":1761794902000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1877056814001364"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,9]]},"references-count":25,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2014,9]]}},"alternative-id":["S1877056814001364"],"URL":"https:\/\/doi.org\/10.1016\/j.otsr.2014.05.005","relation":{},"ISSN":["1877-0568"],"issn-type":[{"value":"1877-0568","type":"print"}],"subject":[],"published":{"date-parts":[[2014,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The effect of posterior non-fusion instrumentation on segmental shear loading of the lumbar spine","name":"articletitle","label":"Article Title"},{"value":"Orthopaedics & Traumatology: Surgery & Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.otsr.2014.05.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Masson SAS. All rights reserved.","name":"copyright","label":"Copyright"}]}}