{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T11:03:38Z","timestamp":1794049418932,"version":"4.8.0"},"reference-count":12,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2015,11,1]],"date-time":"2015-11-01T00:00:00Z","timestamp":1446336000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,11,1]],"date-time":"2015-11-01T00:00:00Z","timestamp":1446336000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2016,11,1]],"date-time":"2016-11-01T00:00:00Z","timestamp":1477958400000},"content-version":"vor","delay-in-days":366,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"published-print":{"date-parts":[[2015,11]]},"DOI":"10.1016\/j.otsr.2015.08.009","type":"journal-article","created":{"date-parts":[[2015,10,30]],"date-time":"2015-10-30T16:40:48Z","timestamp":1446223248000},"page":"857-859","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":40,"title":["Treatment of vertebral compression fractures with the cranio-caudal expandable implant SpineJack\u00ae: Technical note and outcomes in 77 consecutive patients"],"prefix":"10.1016","volume":"101","author":[{"given":"C.","family":"Renaud","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"3","key":"10.1016\/j.otsr.2015.08.009_bib0005","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.spinee.2007.04.004","article-title":"Comparison of vertebroplasty and balloon kyphoplasty for treatment of vertebral compression fractures: a meta-analysis of the literature","volume":"8","author":"Eck","year":"2008","journal-title":"Spine J"},{"issue":"11","key":"10.1016\/j.otsr.2015.08.009_bib0010","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.1097\/BRS.0b013e3181a3c742","article-title":"Percutaneous treatment of vertebral compression fractures: a meta-analysis of complications","volume":"34","author":"Lee","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4","key":"10.1016\/j.otsr.2015.08.009_bib0015","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1586\/erd.12.27","article-title":"Balloon kyphoplasty in patients with osteoporotic vertebral compression fractures","volume":"9","author":"Wardlaw","year":"2012","journal-title":"Expert Rev Med Devices"},{"key":"10.1016\/j.otsr.2015.08.009_bib0020","doi-asserted-by":"crossref","first-page":"934206","DOI":"10.1155\/2014\/934206","article-title":"Controversial issues in kyphoplasty and vertebroplasty in osteoporotic vertebral fractures","volume":"2014","author":"Papanastassiou","year":"2014","journal-title":"Biomed Res Int"},{"issue":"12","key":"10.1016\/j.otsr.2015.08.009_bib0025","doi-asserted-by":"crossref","first-page":"2227","DOI":"10.3174\/ajnr.A4127","article-title":"KAVIAR investigators. A randomized trial comparing balloon kyphoplasty and vertebroplasty for vertebral compression fractures due to osteoporosis","volume":"35","author":"Dohm","year":"2014","journal-title":"AJNR Am J Neuroradiol"},{"issue":"5","key":"10.1016\/j.otsr.2015.08.009_bib0030","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1016\/j.spinee.2013.06.094","article-title":"Height restoration of osteoporotic vertebral compression fractures using different intravertebral reduction devices: a cadaveric study","volume":"15","author":"Kr\u00fcger","year":"2015","journal-title":"Spine J"},{"key":"10.1016\/j.otsr.2015.08.009_bib0035","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.clinbiomech.2013.06.007","article-title":"Height restoration and maintenance after treating unstable osteoporotic vertebral compression fractures by cement augmentation is dependent on the cement volume used","volume":"28","author":"Kr\u00fcger","year":"2013","journal-title":"Clin Biomech"},{"key":"10.1016\/j.otsr.2015.08.009_bib0040","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1097\/01.ajp.0000148628.69627.82","article-title":"Clinically significant change in pain intensity rating in persons with spinal cord injury or amputation","volume":"22","author":"Hanley","year":"2006","journal-title":"Clin J Pain"},{"issue":"4","key":"10.1016\/j.otsr.2015.08.009_bib0045","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1097\/BRS.0b013e31826b3aef","article-title":"Balloon kyphoplasty versus KIVA vertebral augmentation \u2013 comparison of 2 techniques for osteoporotic vertebral body fractures \u2013 a prospective randomized study","volume":"38","author":"Korovessis","year":"2013","journal-title":"Spine"},{"key":"10.1016\/j.otsr.2015.08.009_bib0050","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1007\/s00586-006-0258-x","article-title":"Prospective study of standalone balloon kyphoplasty with calcium phosphate cement augmentation in traumatic fractures","volume":"16","author":"Maestretti","year":"2007","journal-title":"Eur Spine J"},{"key":"10.1016\/j.otsr.2015.08.009_bib0055","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.ijsp.2012.02.005","article-title":"Cement interdigitation and bone-cement interface after augmenting fractured vertebrae: a cadaveric study","volume":"6","author":"Kr\u00fcger","year":"2012","journal-title":"Int J Spine Surg"},{"issue":"8","key":"10.1016\/j.otsr.2015.08.009_bib0060","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1080\/02841850600854928","article-title":"Incidence of adjacent vertebral fractures in patients treated with balloon kyphoplasty: two years\u2019 prospective follow-up","volume":"47","author":"Pflugmacher","year":"2006","journal-title":"Acta Radiol"}],"container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S187705681500225X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S187705681500225X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T03:31:34Z","timestamp":1761795094000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S187705681500225X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11]]},"references-count":12,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2015,11]]}},"alternative-id":["S187705681500225X"],"URL":"https:\/\/doi.org\/10.1016\/j.otsr.2015.08.009","relation":{},"ISSN":["1877-0568"],"issn-type":[{"value":"1877-0568","type":"print"}],"subject":[],"published":{"date-parts":[[2015,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Treatment of vertebral compression fractures with the cranio-caudal expandable implant SpineJack\u00ae: Technical note and outcomes in 77 consecutive patients","name":"articletitle","label":"Article Title"},{"value":"Orthopaedics & Traumatology: Surgery & Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.otsr.2015.08.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Elsevier Masson SAS. All rights reserved.","name":"copyright","label":"Copyright"}]}}