{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T03:32:33Z","timestamp":1791084753641,"version":"4.1.0"},"reference-count":24,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2019,5,1]],"date-time":"2019-05-01T00:00:00Z","timestamp":1556668800000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"published-print":{"date-parts":[[2018,5]]},"DOI":"10.1016\/j.otsr.2017.10.020","type":"journal-article","created":{"date-parts":[[2018,2,6]],"date-time":"2018-02-06T19:12:07Z","timestamp":1517944327000},"page":"377-381","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":24,"title":["Vascular complication after percutaneous femoral cerclage wire"],"prefix":"10.1016","volume":"104","author":[{"given":"M.","family":"Ehlinger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Niglis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.","family":"Favreau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Kuntz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Bierry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Adam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Bonnomet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.otsr.2017.10.020_bib0125","doi-asserted-by":"crossref","first-page":"1992","DOI":"10.1016\/j.injury.2015.07.001","article-title":"Subtrochanteric fracture: the effect of cerclage wire on fracture reduction and outcome","volume":"46","author":"Hoskins","year":"2015","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2017.10.020_bib0130","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1007\/s00402-014-2023-7","article-title":"Percutaneous cerclage followed by intra-medullary nailing for subtrochanteric femoral fractures: a technical note with clinical results","volume":"134","author":"Kim","year":"2014","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.otsr.2017.10.020_bib0135","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1111\/os.12052","article-title":"Locking plate fixation of periprosthetic femur fractures with and without cerclage wires","volume":"5","author":"Ebraheim","year":"2013","journal-title":"Orthop Surg"},{"key":"10.1016\/j.otsr.2017.10.020_bib0140","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1007\/s00590-016-1761-3","article-title":"Combination of low-contact cerclage wiring and osteosynthesis in the treatment of femoral fractures","volume":"26","author":"Angelini","year":"2016","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"10.1016\/j.otsr.2017.10.020_bib0145","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s00264-012-1702-7","article-title":"Biomechanical performance of different cable and wire cerclage configurations","volume":"37","author":"Lenz","year":"2013","journal-title":"Int Orthop"},{"key":"10.1016\/j.otsr.2017.10.020_bib0150","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1177\/1602400319","article-title":"Effect of cable cerclage on regional blood circulation in rabbits: a scintigraphy study","volume":"24","author":"Karakoyun","year":"2016","journal-title":"J Orthop Surg"},{"key":"10.1016\/j.otsr.2017.10.020_bib0155","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.injury.2012.10.016","article-title":"Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study","volume":"44","author":"Apivatthakakul","year":"2013","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2017.10.020_bib0160","doi-asserted-by":"crossref","first-page":"S51","DOI":"10.1016\/S0020-1383(16)47009-9","article-title":"Managing Vancouver B1 fractures by cerclage system compared to locking plate fixation \u2013 a biomechanical study","volume":"47","author":"Gordon","year":"2016","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2017.10.020_bib0165","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1007\/s00402-012-1489-4","article-title":"Percutaneous cerclage wiring and minimally invasive plate osteosynthesis (MIPO): a percutaneous reduction technique in the treatment of Vancouver type B1 periprosthetic femoral shaft fractures","volume":"132","author":"Apivatthakakul","year":"2012","journal-title":"Arch Orthop trauma Surg"},{"key":"10.1016\/j.otsr.2017.10.020_bib0170","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1016\/j.otsr.2013.01.011","article-title":"Minimally invasive fixation of type B et C interprosthetic femoral fractures","volume":"99","author":"Ehlinger","year":"2013","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2017.10.020_bib0175","doi-asserted-by":"crossref","first-page":"1921","DOI":"10.1007\/s00264-015-2928-y","article-title":"Minimally invasive surgery with locking plate periprosthetic femoral fractures: technical note","volume":"39","author":"Ehlinger","year":"2015","journal-title":"Int Orthop"},{"key":"10.1016\/j.otsr.2017.10.020_bib0180","doi-asserted-by":"crossref","first-page":"e932","DOI":"10.3928\/01477447-20140924-90","article-title":"Intravascular migration of a broken cerclage wire into the left heart","volume":"37","author":"Leonardi","year":"2014","journal-title":"Orthopedics"},{"key":"10.1016\/j.otsr.2017.10.020_bib0185","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1007\/s00402-016-2580-z","article-title":"Amputated limb by cerclage wire of femoral diaphyseal fracture: a case report","volume":"136","author":"Won","year":"2016","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.otsr.2017.10.020_bib0190","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1016\/j.arth.2004.12.050","article-title":"Femoral artery an vein injury after cerclage wiring of the femur: a case report","volume":"20","author":"Mehta","year":"2005","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2017.10.020_bib0195","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/00005373-199601000-00004","article-title":"Treatment of femur fracture with associated vascular injury","volume":"40","author":"Starr","year":"1996","journal-title":"J Trauma Acute care Surg"},{"key":"10.1016\/j.otsr.2017.10.020_bib0200","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s00402-003-0618-5","article-title":"Position of the superficial femoral artery in closed hip nailing","volume":"124","author":"Yang","year":"2004","journal-title":"Arch Orthop trauma Surg"},{"key":"10.1016\/j.otsr.2017.10.020_bib0205","doi-asserted-by":"crossref","first-page":"545","DOI":"10.4103\/0019-5413.118200","article-title":"Results of titanium locking plate and stainless steel cerclage wire combination in femoral fractures","volume":"47","author":"El-Zayat","year":"2013","journal-title":"Indian J Orthop"},{"key":"10.1016\/j.otsr.2017.10.020_bib0210","doi-asserted-by":"crossref","first-page":"1915","DOI":"10.1007\/s00264-012-1574-x","article-title":"The locking attachment plate for proximal fixation of periprosthetic femur fractures \u2013 a biomechanical comparison of two techniques","volume":"36","author":"Lenz","year":"2012","journal-title":"Int Orthop"},{"key":"10.1016\/j.otsr.2017.10.020_bib0215","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/s00264-013-2113-0","article-title":"Biomechanical comparison of two angular stable plate construction for periprosthetic femur fracture fixation","volume":"38","author":"Wahnert","year":"2014","journal-title":"Int Orthop"},{"key":"10.1016\/j.otsr.2017.10.020_bib0220","doi-asserted-by":"crossref","first-page":"S71","DOI":"10.1016\/j.injury.2013.10.027","article-title":"A biomechanical study on proximal plate fixation techniques in periprosthetic femur fractures","volume":"45","author":"Lenz","year":"2014","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2017.10.020_bib0225","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1007\/s00064-011-0091-1","article-title":"Minimally invasive periprosthetic plate osteosynthesis using the locking attachment plate","volume":"25","author":"Kammerlander","year":"2013","journal-title":"Oper Orthop Traumatol"},{"key":"10.1016\/j.otsr.2017.10.020_bib0230","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1016\/j.injury.2013.06.013","article-title":"A biomechanical study comparing polyaxial locking screw mechanisms","volume":"44","author":"Hebert-Davies j","year":"2013","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2017.10.020_bib0235","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s12570-012-0130-x","article-title":"Periprosthetic fractures around the knee \u2013 the best way of treatment","volume":"4","author":"Ruchholtz","year":"2013","journal-title":"Eur Orthop Traumatol"},{"key":"10.1016\/j.otsr.2017.10.020_bib0240","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.injury.2012.10.035","article-title":"Less invasive polaxial locking plate fixation in periprosthetic and peri-implant fractures of the femur \u2013 a prospective study of 41 patients","volume":"44","author":"Ruchholtz","year":"2013","journal-title":"Injury"}],"container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056818300379?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056818300379?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T03:37:23Z","timestamp":1761795443000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1877056818300379"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,5]]}},"alternative-id":["S1877056818300379"],"URL":"https:\/\/doi.org\/10.1016\/j.otsr.2017.10.020","relation":{},"ISSN":["1877-0568"],"issn-type":[{"value":"1877-0568","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Vascular complication after percutaneous femoral cerclage wire","name":"articletitle","label":"Article Title"},{"value":"Orthopaedics & Traumatology: Surgery & Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.otsr.2017.10.020","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Masson SAS.","name":"copyright","label":"Copyright"}]}}