{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T07:09:32Z","timestamp":1761808172825,"version":"build-2065373602"},"reference-count":26,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2019,5,1]],"date-time":"2019-05-01T00:00:00Z","timestamp":1556668800000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"name":"Stryker Japan"},{"name":"Japan Medical Dynamic Marketing"},{"name":"Sofamor Danek"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"published-print":{"date-parts":[[2018,5]]},"DOI":"10.1016\/j.otsr.2017.12.009","type":"journal-article","created":{"date-parts":[[2018,1,30]],"date-time":"2018-01-30T22:04:12Z","timestamp":1517349852000},"page":"307-315","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Do screws and screw holes affect osteolysis in cementless cups using highly crosslinked polyethylene? A 7 to 10-year follow-up case\u2013control study"],"prefix":"10.1016","volume":"104","author":[{"given":"N.","family":"Taniguchi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8629-2283","authenticated-orcid":false,"given":"T.","family":"Jinno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Takada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Koga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Ando","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Okawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Haro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.otsr.2017.12.009_bib0005","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1302\/0301-620X.79B5.0790844","article-title":"Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method","volume":"79","author":"Kobayashi","year":"1997","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.otsr.2017.12.009_bib0010","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1016\/j.otsr.2014.07.015","article-title":"Does crosslinked polyethylene decrease the revision rate of total hip arthroplasty compared with conventional polyethylene? A meta-analysis","volume":"100","author":"Shen","year":"2014","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2017.12.009_bib0015","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.otsr.2016.04.010","article-title":"Comparison of wear rate and osteolysis between annealed and remelted highly crosslinked polyethylene in total hip arthroplasty. A case\u2013control study at 7 to 10 years follow-up","volume":"102","author":"Takada","year":"2016","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2017.12.009_bib0020","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1302\/0301-620X.98B1.36527","article-title":"Highly crosslinked polyethylene decreases the rate of revision of total hip arthroplasty compared with conventional polyethylene at 13 years\u2019 follow-up","volume":"98","author":"Hanna","year":"2016","journal-title":"Bone Joint J"},{"key":"10.1016\/j.otsr.2017.12.009_bib0025","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1503\/cjs.005216","article-title":"Thirteen-year wear rate comparison of highly crosslinked and conventional polyethylene in total hip arthroplasty: long-term follow-up of a prospective randomized controlled trial","volume":"60","author":"Teeter","year":"2017","journal-title":"Can J Surg"},{"key":"10.1016\/j.otsr.2017.12.009_bib0030","doi-asserted-by":"crossref","first-page":"58","DOI":"10.2106\/00004623-200201000-00009","article-title":"Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty","volume":"84","author":"Young","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2017.12.009_bib0035","doi-asserted-by":"crossref","first-page":"509","DOI":"10.2106\/00004623-199072040-00006","article-title":"Structures at risk from medially placed acetabular screws","volume":"72","author":"Keating","year":"1990","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2017.12.009_bib0040","doi-asserted-by":"crossref","first-page":"849","DOI":"10.2106\/00004623-199274060-00006","article-title":"Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space","volume":"74","author":"Schmalzried","year":"1992","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2017.12.009_bib0045","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1302\/0301-620X.76B4.8027142","article-title":"Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components","volume":"76","author":"Huk","year":"1994","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.otsr.2017.12.009_bib0050","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1080\/17453674.2016.1190244","article-title":"No effect of additional screw fixation of a cementless, all-polyethylene press-fit socket on migration, wear and clinical outcome","volume":"87","author":"Minten","year":"2016","journal-title":"Acta Orthop"},{"key":"10.1016\/j.otsr.2017.12.009_bib0055","doi-asserted-by":"crossref","first-page":"705","DOI":"10.5312\/wjo.v8.i9.705","article-title":"Acetabular components with or without screws in total hip arthroplasty","volume":"8","author":"Pepe","year":"2017","journal-title":"World J Orthop"},{"key":"10.1016\/j.otsr.2017.12.009_bib0060","doi-asserted-by":"crossref","first-page":"481","DOI":"10.3109\/17453674.2012.720116","article-title":"A cementless, elastic press-fit socket with and without screws","volume":"83","author":"Pakvis","year":"2012","journal-title":"Acta Orthop"},{"key":"10.1016\/j.otsr.2017.12.009_bib0065","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1054\/arth.2000.2963","article-title":"Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips","volume":"15","author":"Thanner","year":"2000","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2017.12.009_bib0070","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1016\/j.arth.2016.12.020","article-title":"Cementless hip stem anteversion in the dysplastic hip: a comparison of tapered wedge vs metaphyseal filling","volume":"32","author":"Taniguchi","year":"2017","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2017.12.009_bib0075","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1097\/00003086-199008000-00022","article-title":"Roentgenographic assessment of the bio-logic fixation of porous-surfaced femoral components","volume":"257","author":"Engh","year":"1990","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2017.12.009_bib0080","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.arth.2006.05.002","article-title":"A randomized prospective evaluation of outcomes after total hip arthroplasty using crosslinked marathon and non-crosslinked enduron polyethylene liners","volume":"21","author":"Engh","year":"2006","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2017.12.009_bib0085","doi-asserted-by":"crossref","first-page":"609","DOI":"10.2106\/00004623-200204000-00016","article-title":"Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty","volume":"84","author":"Puri","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2017.12.009_bib0090","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.arth.2016.06.008","article-title":"Fifteen-year comparison of wear and osteolysis analysis for crosslinked or conventional polyethylene in cementless total hip arthroplasty for hip dysplasia-A retrospective cohort study","volume":"32","author":"Tsukamoto","year":"2017","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2017.12.009_bib0095","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.otsr.2017.02.004","article-title":"Comparison of wear rate and osteolysis between second-generation annealed and first-generation remelted highly crosslinked polyethylene in total hip arthroplasty. A case\u2013control study at a minimum of five years","volume":"103","author":"Takada","year":"2017","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2017.12.009_bib0100","doi-asserted-by":"crossref","first-page":"175","DOI":"10.3758\/BF03193146","article-title":"G*Power 3: a flexible statistical power analysis program for the social, behavioral and biomedical sciences","volume":"39","author":"Faul","year":"2007","journal-title":"Behav Res Methods"},{"key":"10.1016\/j.otsr.2017.12.009_bib0105","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.arth.2014.08.027","article-title":"Cluster hole versus solid cup in total hip arthroplasty: a randomized control trial","volume":"30","author":"Blakeney","year":"2015","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2017.12.009_bib0110","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.otsr.2010.04.007","article-title":"Dual mobility hip arthroplasty wear measurement: experimental accuracy assessment using radiostereometric analysis (RSA)","volume":"96","author":"Pineau","year":"2010","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2017.12.009_bib0115","doi-asserted-by":"crossref","first-page":"119","DOI":"10.3109\/17453679809117610","article-title":"EBRA improves the accuracy of radiographic analysis of acetabular cup migration","volume":"69","author":"Ilchmann","year":"1998","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.otsr.2017.12.009_bib0120","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.arth.2016.02.076","article-title":"Thirteen-year evaluation of highly crosslinked polyethylene articulating with either 28-mm or 36-mm femoral heads using radiostereometric analysis and computerized tomography","volume":"31","author":"Nebergall","year":"2016","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2017.12.009_bib0125","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1007\/s11999-015-4471-y","article-title":"Backside wear is not dependent on the acetabular socket design in crosslinked polyethylene liners","volume":"474","author":"Bali","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2017.12.009_bib0130","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1302\/0301-620X.99B5.BJJ-2016-0968.R1","article-title":"Radiographic scoring system for the evaluation of stability of cementless acetabular components in the presence of osteolysis","volume":"99","author":"Narkbunnam","year":"2017","journal-title":"Bone Joint J"}],"container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056818300239?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056818300239?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T03:37:39Z","timestamp":1761795459000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1877056818300239"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,5]]}},"alternative-id":["S1877056818300239"],"URL":"https:\/\/doi.org\/10.1016\/j.otsr.2017.12.009","relation":{},"ISSN":["1877-0568"],"issn-type":[{"type":"print","value":"1877-0568"}],"subject":[],"published":{"date-parts":[[2018,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Do screws and screw holes affect osteolysis in cementless cups using highly crosslinked polyethylene? A 7 to 10-year follow-up case\u2013control study","name":"articletitle","label":"Article Title"},{"value":"Orthopaedics & Traumatology: Surgery & Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.otsr.2017.12.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Masson SAS.","name":"copyright","label":"Copyright"}]}}