{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T07:11:31Z","timestamp":1761808291500,"version":"build-2065373602"},"reference-count":26,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,10,1]],"date-time":"2020-10-01T00:00:00Z","timestamp":1601510400000},"content-version":"vor","delay-in-days":366,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"published-print":{"date-parts":[[2019,10]]},"DOI":"10.1016\/j.otsr.2019.04.008","type":"journal-article","created":{"date-parts":[[2019,6,6]],"date-time":"2019-06-06T01:43:04Z","timestamp":1559785384000},"page":"1039-1045","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Flexion gap stabilization by oversizing posterior condylar offset in deep-dished total knee replacement does not compromise flexion: A single-surgeon, retrospective, observational, mid-term series"],"prefix":"10.1016","volume":"105","author":[{"given":"Philippe","family":"Massin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edouard","family":"Lefevre","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julien","family":"Serane","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.otsr.2019.04.008_bib0135","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1097\/00003086-199811000-00009","article-title":"In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis","volume":"356","author":"Dennis","year":"1998","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2019.04.008_bib0140","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1097\/00003086-199610000-00015","article-title":"In vivo knee kinematics derived using an inverse perspective technique","volume":"331","author":"Dennis","year":"1996","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2019.04.008_bib0145","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1302\/0301-620X.77B6.7593100","article-title":"Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty","volume":"77","author":"Stiehl","year":"1995","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.otsr.2019.04.008_bib0150","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1007\/s00167-004-0567-8","article-title":"Assessment of posterior stability in total knee replacement by stress radiographs: prospective comparison of two different types of mobile bearing implants","volume":"13","author":"Louisia","year":"2005","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.otsr.2019.04.008_bib0155","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1016\/j.otsr.2015.07.024","article-title":"Cruciate-sacrificing total knee arthroplasty and insert design: a radiologic study of sagittal laxity","volume":"101","author":"Appy Fedida","year":"2015","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2019.04.008_bib0160","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.otsr.2014.03.014","article-title":"Medium-term osteolysis with the wallaby i(r) deep-dished total knee prosthesis","volume":"100","author":"Marion","year":"2014","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2019.04.008_bib0165","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1097\/00003086-200111000-00029","article-title":"Polyethylene contact stresses, articular congruity, and knee alignment","volume":"392","author":"D\u2019Lima","year":"2001","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2019.04.008_bib0170","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/j.knee.2010.06.007","article-title":"Intra-operative navigation of knee kinematics and the influence of osteoarthritis","volume":"18","author":"Massin","year":"2001","journal-title":"Knee"},{"key":"10.1016\/j.otsr.2019.04.008_bib0175","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1007\/s00167-015-3561-4","article-title":"Control of paradoxical kinematics in posterior cruciate-retaining total knee arthroplasty by increasing posterior femoral offset","volume":"23","author":"Donadio","year":"2015","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.otsr.2019.04.008_bib0180","doi-asserted-by":"crossref","DOI":"10.1177\/2309499017690976","article-title":"Comparative evaluation of posterior cruciate ligament in total knee arthroplasty","volume":"25","author":"Ma","year":"2017","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"10.1016\/j.otsr.2019.04.008_bib0185","doi-asserted-by":"crossref","first-page":"2704","DOI":"10.1007\/s00167-012-2059-6","article-title":"Significant effect of the posterior tibial slope and medial\/lateral ligament balance on knee flexion in total knee arthroplasty","volume":"21","author":"Fujimoto","year":"2013","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.otsr.2019.04.008_bib0190","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/S0883-5403(97)90021-8","article-title":"Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris","volume":"12","author":"Devane","year":"1997","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2019.04.008_bib0195","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/00003086-198911000-00004","article-title":"Rationale of the knee society clinical rating system","volume":"248","author":"Insall","year":"1989","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2019.04.008_bib0200","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2011.06.035","article-title":"The \u201cforgotten joint\u201d as the ultimate goal in joint arthroplasty: validation of a new patient-reported outcome measure","volume":"27","author":"Behrend","year":"2012","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2019.04.008_bib0205","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/00003086-198911000-00003","article-title":"The knee society total knee arthroplasty roentgenographic evaluation and scoring system","volume":"248","author":"Ewald","year":"1989","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2019.04.008_bib0210","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1007\/s00167-013-2731-5","article-title":"Influence of intentional femoral component flexion in navigated tka on gap balance and sagittal anatomy","volume":"22","author":"Rosskopf","year":"2017","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.otsr.2019.04.008_bib0215","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.arth.2004.02.008","article-title":"Stiffness after total knee arthroplasty","volume":"19","author":"Laskin","year":"2004","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2019.04.008_bib0220","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1007\/s00167-013-2525-9","article-title":"Do tibiofemoral contact point and posterior condylar offset influence outcome and range of motion in a mobile-bearing total knee arthroplasty?","volume":"22","author":"Geijsen","year":"2014","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.otsr.2019.04.008_bib0225","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1302\/0301-620X.84B1.0840050","article-title":"Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset","volume":"84","author":"Bellemans","year":"2002","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.otsr.2019.04.008_bib0230","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1016\/j.arth.2005.10.019","article-title":"Optimization of the posterior condylar offset, tibial slope, and condylar roll-back in total knee arthroplasty","volume":"21","author":"Massin","year":"2006","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2019.04.008_bib0235","doi-asserted-by":"crossref","first-page":"1362","DOI":"10.2106\/00004623-200208000-00012","article-title":"Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design: five to eight-year follow-up","volume":"84","author":"O\u2019Rourke","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2019.04.008_bib0240","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1007\/s00167-008-0637-4","article-title":"In vivo flexion and kinematics of the knee after tka: comparison of a conventional and a high flexion cruciate-retaining tka design","volume":"17","author":"Suggs","year":"2009","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.otsr.2019.04.008_bib0245","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1097\/00003086-200107000-00013","article-title":"Ten- to 14-year clinical followup of the cementless natural knee system","volume":"388","author":"Hofmann","year":"2001","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2019.04.008_bib0250","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1097\/00003086-200011000-00006","article-title":"Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study","volume":"380","author":"Laskin","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2019.04.008_bib0255","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1007\/s00167-013-2660-3","article-title":"A new spacer-guided, pcl balancing technique for cruciate-retaining total knee replacement","volume":"22","author":"Heesterbeek","year":"2014","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.otsr.2019.04.008_bib0260","doi-asserted-by":"crossref","first-page":"2709","DOI":"10.1007\/s00167-013-2579-8","article-title":"Influence of the anterior-posterior femoral translation on the range of motion in cruciate-retaining total knee arthroplasty","volume":"22","author":"Yanagisawa","year":"2014","journal-title":"Knee Surg Sports Traumatol Arthrosc"}],"container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056819301598?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056819301598?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T03:41:35Z","timestamp":1761795695000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1877056819301598"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10]]},"references-count":26,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019,10]]}},"alternative-id":["S1877056819301598"],"URL":"https:\/\/doi.org\/10.1016\/j.otsr.2019.04.008","relation":{},"ISSN":["1877-0568"],"issn-type":[{"type":"print","value":"1877-0568"}],"subject":[],"published":{"date-parts":[[2019,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Flexion gap stabilization by oversizing posterior condylar offset in deep-dished total knee replacement does not compromise flexion: A single-surgeon, retrospective, observational, mid-term series","name":"articletitle","label":"Article Title"},{"value":"Orthopaedics & Traumatology: Surgery & Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.otsr.2019.04.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier Masson SAS.","name":"copyright","label":"Copyright"}]}}