{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T09:19:37Z","timestamp":1792747177537,"version":"4.5.0"},"reference-count":44,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"vor","delay-in-days":366,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1016\/j.otsr.2019.04.027","type":"journal-article","created":{"date-parts":[[2019,7,22]],"date-time":"2019-07-22T16:50:49Z","timestamp":1563814249000},"page":"95-101","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":41,"title":["Comparative finite element analysis of three implants fixing stable and unstable subtrochanteric femoral fractures: Proximal Femoral Nail Antirotation (PFNA), Proximal Femoral Locking Plate (PFLP), and Reverse Less Invasive Stabilization System (LISS)"],"prefix":"10.1016","volume":"106","author":[{"given":"Jie","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian-Xiong","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bin","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao-Hao","family":"Bai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin-Long","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.otsr.2019.04.027_bib0225","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1097\/00003086-199210000-00032","article-title":"Subtrochanteric fractures of the femur. Results of treatment by interlocking nailing","volume":"283","author":"Wiss","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2019.04.027_bib0230","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1016\/j.otsr.2015.06.018","article-title":"Subtrochanteric femoral fractures treated with the Long Gamma3(R) nail: A historical control case study versus Long trochanteric Gamma nail(R)","volume":"101","author":"Georgiannos","year":"2015","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2019.04.027_bib0235","doi-asserted-by":"crossref","first-page":"S75","DOI":"10.1016\/j.otsr.2013.11.007","article-title":"Treatment of recent trochanteric fracture in adults","volume":"100","author":"Adam","year":"2014","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2019.04.027_bib0240","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1111\/os.12109","article-title":"Biomechanical analysis of four types of internal fixation in subtrochanteric fracture models","volume":"6","author":"Wang","year":"2014","journal-title":"Orthop Surg"},{"key":"10.1016\/j.otsr.2019.04.027_bib0245","doi-asserted-by":"crossref","first-page":"e3382","DOI":"10.1097\/MD.0000000000003382","article-title":"Biomechanical evaluation of four methods for internal fixation of comminuted subtrochanteric fractures","volume":"95","author":"Wang","year":"2016","journal-title":"Medicine"},{"key":"10.1016\/j.otsr.2019.04.027_bib0250","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.injury.2008.10.014","article-title":"The AO\/ASIF proximal femoral nail antirotation (PFNA): a new design for the treatment of unstable proximal femoral fractures","volume":"40","author":"Mereddy","year":"2009","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2019.04.027_bib0255","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.injury.2008.02.005","article-title":"The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study","volume":"39","author":"Simmermacher","year":"2008","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2019.04.027_bib0260","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/j.otsr.2011.11.006","article-title":"Proximal femoral nail antirotation (PFN-ATM) fixation of extra-capsular proximal femoral fractures in the elderly: retrospective study in 102 patients","volume":"98","author":"Soucanye de Landevoisin","year":"2012","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2019.04.027_bib0265","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1097\/BOT.0b013e31822c53c1","article-title":"Central head perforation, or \u201ccut through,\u201d caused by the helical blade of the proximal femoral nail antirotation","volume":"26","author":"Frei","year":"2012","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.otsr.2019.04.027_bib0270","doi-asserted-by":"crossref","first-page":"1292","DOI":"10.1016\/j.injury.2010.07.499","article-title":"Clinical comparison of the second and third generation of intramedullary devices for trochanteric fractures of the hip-Blade vs screw","volume":"41","author":"Lenich","year":"2010","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2019.04.027_bib0275","first-page":"169","article-title":"The proximal femur nail antirotation: an identifiable improvement in the treatment of unstable pertrochanteric fractures?","volume":"71","author":"Gardenbroek","year":"2011","journal-title":"J Trauma"},{"key":"10.1016\/j.otsr.2019.04.027_bib0280","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1590\/S1413-78522012000600003","article-title":"Treatment of femoral subtrochanteric fractures with proximal lateral femur locking plates","volume":"20","author":"Hu","year":"2012","journal-title":"Acta Ortop Bras"},{"key":"10.1016\/j.otsr.2019.04.027_bib0285","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1007\/s00402-010-1074-7","article-title":"Fixation failure of the LCP proximal femoral Plate 4.5\/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur","volume":"130","author":"Wieser","year":"2010","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.otsr.2019.04.027_bib0290","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1097\/BOT.0b013e3181e31ccc","article-title":"Failure of proximal femoral locking compression plate: a case series","volume":"25","author":"Glassner","year":"2011","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.otsr.2019.04.027_bib0295","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/BOT.0b013e318251930d","article-title":"Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures","volume":"27","author":"Streubel","year":"2013","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.otsr.2019.04.027_bib0300","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.injury.2013.02.020","article-title":"High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate","volume":"44","author":"Wirtz","year":"2013","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2019.04.027_bib0305","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.injury.2005.09.022","article-title":"plate stabilisation of a subtrochanteric fracture of the femur in a patient with osteopetrosis: is this the answer?","volume":"37","author":"Sidhom","year":"2006","journal-title":"Injury Extra"},{"key":"10.1016\/j.otsr.2019.04.027_bib0310","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.injury.2006.08.052","article-title":"plating for proximal segmental femoral fractures in the polytrauma patient: a case report","volume":"38","author":"Pryce Lewis","year":"2007","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2019.04.027_bib0315","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1177\/112070000901900211","article-title":"Minimally invasive management of unstable proximal femoral extracapsular fractures using reverse LISS femoral locking plates","volume":"19","author":"Ozkaya","year":"2009","journal-title":"Hip Int"},{"key":"10.1016\/j.otsr.2019.04.027_bib0320","doi-asserted-by":"crossref","first-page":"1659","DOI":"10.1007\/s00402-009-0815-y","article-title":"Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures","volume":"129","author":"Oh","year":"2009","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.otsr.2019.04.027_bib0325","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/j.injury.2010.03.028","article-title":"Reverse LISS plates for unstable proximal femoral fractures","volume":"41","author":"Ma","year":"2010","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2019.04.027_bib0330","doi-asserted-by":"crossref","first-page":"347","DOI":"10.4103\/0019-5413.156220","article-title":"A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation: A study on synthetic bones","volume":"49","author":"Ozkan","year":"2015","journal-title":"Indian J Orthop"},{"key":"10.1016\/j.otsr.2019.04.027_bib0335","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1159\/000335986","article-title":"Using the contralateral reverse less invasive plating system for subtrochanteric femur fractures in elderly patients","volume":"21","author":"Ouyang","year":"2012","journal-title":"Med Princ Pract"},{"key":"10.1016\/j.otsr.2019.04.027_bib0340","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1016\/j.ijsu.2014.03.006","article-title":"A retrospective analysis of reversed femoral Less Invasive Stable System (LISS) for treatment of subtrochanteric femoral fracture","volume":"12","author":"Li","year":"2014","journal-title":"Int J Surg"},{"key":"10.1016\/j.otsr.2019.04.027_bib0345","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1243\/09544119JEIM799","article-title":"A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests","volume":"224","author":"Eberle","year":"2010","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.otsr.2019.04.027_bib0350","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1243\/09544119JEIM156","article-title":"Finite element analysis of a subtrochanteric fractured femur with dynamic hip screw, dynamic condylar screw, and proximal femur nail implants\u2013a comparative study","volume":"222","author":"Sowmyanarayanan","year":"2008","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.otsr.2019.04.027_bib0355","doi-asserted-by":"crossref","first-page":"300","DOI":"10.2106\/00004623-197860030-00004","article-title":"Subtrochanteric fractures of the femur","volume":"60","author":"Seinsheimer","year":"1978","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2019.04.027_bib0360","doi-asserted-by":"crossref","first-page":"1972","DOI":"10.1007\/s11999-009-0800-3","article-title":"Type of hip fracture determines load share in intramedullary osteosynthesis","volume":"467","author":"Eberle","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2019.04.027_bib0365","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1002\/jbm.1233","article-title":"Static coefficient of friction between Ti-6Al-4V and PMMA for cemented hip and knee implants","volume":"59","author":"Nuno","year":"2002","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.otsr.2019.04.027_bib0370","doi-asserted-by":"crossref","first-page":"2045","DOI":"10.1016\/j.injury.2014.07.014","article-title":"Finite element analysis of the effect of cannulated screw placement and drilling frequency on femoral neck fracture fixation","volume":"45","author":"Mei","year":"2014","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2019.04.027_bib0375","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/s00264-006-0088-9","article-title":"Treatment of subtrochanteric fractures. A comparison of the Gamma nail and the dynamic hip screw: short-term outcome in 58 patients","volume":"31","author":"Saarenpaa","year":"2007","journal-title":"Inter Orthop"},{"key":"10.1016\/j.otsr.2019.04.027_bib0380","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1302\/0301-620X.87B1.15295","article-title":"The standard Gamma nail or the Medoff sliding plate for unstable trochanteric and subtrochanteric fractures. A randomised, controlled trial","volume":"87","author":"Miedel","year":"2005","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.otsr.2019.04.027_bib0385","first-page":"803","article-title":"Intramedullary versus extramedullary fixation in the management of subtrochanteric femur fractures: a meta-analysis","volume":"10","author":"Liu","year":"2015","journal-title":"Clin Interv Aging"},{"key":"10.1016\/j.otsr.2019.04.027_bib0390","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.otsr.2014.07.023","article-title":"Proximal femoral nails antirotation, Gamma nails, and dynamic hip screws for fixation of intertrochanteric fractures of femur: A meta-analysis","volume":"100","author":"Ma","year":"2014","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2019.04.027_bib0395","first-page":"E19","article-title":"A biomechanical analysis of locking plate fixation with minimally invasive plate osteosynthesis in a subtrochanteric fracture model","volume":"70","author":"Kim","year":"2011","journal-title":"J Trauma"},{"key":"10.1016\/j.otsr.2019.04.027_bib0400","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1097\/BOT.0b013e3182254ea3","article-title":"A biomechanical comparison of a locking plate, a nail, and a 95 degrees angled blade plate for fixation of subtrochanteric femoral fractures","volume":"26","author":"Forward","year":"2012","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.otsr.2019.04.027_bib0405","doi-asserted-by":"crossref","first-page":"B11","DOI":"10.1016\/j.injury.2003.09.021","article-title":"Biomechanical testing of the LCP\u2013how can stability in locked internal fixators be controlled?","volume":"34","author":"Stoffel","year":"2003","journal-title":"Injury"},{"key":"10.1016\/j.otsr.2019.04.027_bib0410","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1243\/09544119JEIM369","article-title":"Biomechanical comparison of three second-generation reconstruction nails in an unstable subtrochanteric femur fracture model","volume":"222","author":"Heiney","year":"2008","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.otsr.2019.04.027_bib0415","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1097\/BOT.0b013e3181b04835","article-title":"Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures","volume":"23","author":"Floyd","year":"2009","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.otsr.2019.04.027_bib0420","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1097\/BOT.0b013e3181a2a31d","article-title":"A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model","volume":"23","author":"Crist","year":"2009","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.otsr.2019.04.027_bib0425","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1186\/1475-925X-11-23","article-title":"Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration of its potential benefits on synthetic femur model with supportive hierarchical nonlinear hyperelastic finite element analysis","volume":"11","author":"Latifi","year":"2012","journal-title":"Biomed Eng Online"},{"key":"10.1016\/j.otsr.2019.04.027_bib0430","first-page":"116","article-title":"Finite element analysis on a medical implant","volume":"60","author":"Semenescu","year":"2016","journal-title":"Rom J Ophthalmol"},{"key":"10.1016\/j.otsr.2019.04.027_bib0435","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1002\/rcs.1584","article-title":"Comparison of the biomechanical effects of pertrochanteric fixator and dynamic hip screw on an intertrochanteric femoral fracture using the finite element method","volume":"11","author":"Inal","year":"2015","journal-title":"Int J Med Robot"},{"key":"10.1016\/j.otsr.2019.04.027_bib0440","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.otsr.2014.03.016","article-title":"Biomechanical effects of vertebroplasty on thoracolumbar burst fracture with transpedicular fixation: a finite element model analysis","volume":"100","author":"Xu","year":"2014","journal-title":"Orthop Traumatol Surg Res"}],"container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056819302051?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056819302051?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T03:41:21Z","timestamp":1761795681000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1877056819302051"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":44,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["S1877056819302051"],"URL":"https:\/\/doi.org\/10.1016\/j.otsr.2019.04.027","relation":{},"ISSN":["1877-0568"],"issn-type":[{"value":"1877-0568","type":"print"}],"subject":[],"published":{"date-parts":[[2020,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparative finite element analysis of three implants fixing stable and unstable subtrochanteric femoral fractures: Proximal Femoral Nail Antirotation (PFNA), Proximal Femoral Locking Plate (PFLP), and Reverse Less Invasive Stabilization System (LISS)","name":"articletitle","label":"Article Title"},{"value":"Orthopaedics & Traumatology: Surgery & Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.otsr.2019.04.027","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier Masson SAS.","name":"copyright","label":"Copyright"}]}}