{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T10:52:05Z","timestamp":1788519125163,"version":"build-2803163510"},"reference-count":37,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,7,17]],"date-time":"2020-07-17T00:00:00Z","timestamp":1594944000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1016\/j.otsr.2020.03.030","type":"journal-article","created":{"date-parts":[[2020,12,28]],"date-time":"2020-12-28T09:10:49Z","timestamp":1609146649000},"page":"102644","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"title":["Wear and migration are not influenced by head size in a vitamin E-infused highly cross-linked polyethylene acetabular cup"],"prefix":"10.1016","volume":"107","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0712-5626","authenticated-orcid":false,"given":"Simon","family":"Comtesse","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arthur","family":"de Gast","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Rehbein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gary","family":"French","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naeder","family":"Helmy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roland","family":"Becker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Dominkus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0697-946X","authenticated-orcid":false,"given":"Martin","family":"Beck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.otsr.2020.03.030_bib0190","doi-asserted-by":"crossref","first-page":"128","DOI":"10.2106\/JBJS.H.00155","article-title":"The epidemiology of revision total hip arthroplasty in the United States","volume":"91","author":"Bozic","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2020.03.030_bib0195","doi-asserted-by":"crossref","first-page":"S6","DOI":"10.1186\/ar2170","article-title":"Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies","volume":"9","author":"Abu-Amer","year":"2007","journal-title":"Arthritis Res Ther"},{"key":"10.1016\/j.otsr.2020.03.030_bib0200","doi-asserted-by":"crossref","first-page":"2262","DOI":"10.1007\/s11999-011-1872-4","article-title":"History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene","volume":"469","author":"Kurtz","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2020.03.030_bib0205","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/j.arth.2005.07.015","article-title":"Mechanical properties of retrieved highly cross-linked crossfire liners after short-term implantation","volume":"20","author":"Kurtz","year":"2005","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2020.03.030_bib0210","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.2106\/00004623-200406000-00021","article-title":"Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners","volume":"86-A","author":"Bradford","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2020.03.030_bib0215","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1016\/j.biomaterials.2005.06.025","article-title":"Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE","volume":"27","author":"Oral","year":"2006","journal-title":"Biomaterials"},{"key":"10.1016\/j.otsr.2020.03.030_bib0220","series-title":"Total Hip Arthroplasty","first-page":"21","article-title":"Oxidation prevention with vitamin E in a HXLPE isoelastic monoblock pressfit cup: preliminary results","author":"Beck","year":"2012"},{"key":"10.1016\/j.otsr.2020.03.030_bib0225","doi-asserted-by":"crossref","first-page":"2286","DOI":"10.1007\/s11999-010-1717-6","article-title":"Vitamin E-stabilised UHMWPE for total joint implants: a review","volume":"469","author":"Bracco","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2020.03.030_bib0230","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1054\/arth.2001.28376","article-title":"Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept","volume":"16","author":"Muratoglu","year":"2001","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2020.03.030_bib0235","doi-asserted-by":"crossref","first-page":"583","DOI":"10.3109\/17453674.2012.745353","article-title":"Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survival studies","volume":"83","author":"Pijls","year":"2012","journal-title":"Acta Orthop"},{"key":"10.1016\/j.otsr.2020.03.030_bib0240","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1302\/0301-620X.78B3.0780422","article-title":"Early migration predicts late aseptic failure of hip sockets","volume":"78","author":"Krismer","year":"1996","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.otsr.2020.03.030_bib0245","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1054\/arth.2002.33664","article-title":"A literature review of the association between wear rate and osteolysis in total hip arthroplasty","volume":"17","author":"Dumbleton","year":"2002","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2020.03.030_bib0250","doi-asserted-by":"crossref","first-page":"368","DOI":"10.5301\/hipint.5000469","article-title":"The RM Pressfit vitamys: 5-year Swiss experience of the first 100 cups","volume":"27","author":"Wyatt","year":"2017","journal-title":"Hip Int"},{"key":"10.1016\/j.otsr.2020.03.030_bib0255","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/j.arth.2012.11.004","article-title":"Five-year results of the uncemented RM pressfit cup clinical evaluation and migration measurements by EBRA","volume":"28","author":"Wyss","year":"2013","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2020.03.030_bib0260","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1016\/0021-9290(94)00177-6","article-title":"EBRA: a method to measure migration of acetabular components","volume":"28","author":"Krismer","year":"1995","journal-title":"J Biomech"},{"key":"10.1016\/j.otsr.2020.03.030_bib0265","doi-asserted-by":"crossref","first-page":"119","DOI":"10.3109\/17453679809117610","article-title":"EBRA improves the accuracy of radiographic analysis of acetabular cup migration","volume":"69","author":"Ilchmann","year":"1998","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.otsr.2020.03.030_bib0270","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1007\/s11420-012-9287-7","article-title":"Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear","volume":"8","author":"Cross","year":"2012","journal-title":"HSS J"},{"key":"10.1016\/j.otsr.2020.03.030_bib0275","first-page":"E53","article-title":"The pros and cons of using larger femoral heads in total hip arthroplasty","volume":"42","author":"Rathi","year":"2013","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"10.1016\/j.otsr.2020.03.030_bib0280","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/s11999-015-4319-5","article-title":"Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 years: the effect of femoral head size","volume":"474","author":"Lachiewicz","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2020.03.030_bib0285","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1016\/j.otsr.2017.03.026","article-title":"Does using a polyethylene RM press-fit cup modify the preparation of the acetabulum and acetabular offset in primary hip arthroplasty?","volume":"103","author":"Erivan","year":"2017","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2020.03.030_bib0290","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.otsr.2016.04.010","article-title":"Comparison of wear rate and osteolysis between annealed and remelted highly cross-linked polyethylene in total hip arthroplasty. A case control study at 7 to 10 years follow-up","volume":"102","author":"Takada","year":"2016","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.otsr.2020.03.030_bib0295","article-title":"The survivorship of the uncemented iso-elastic monoblock acetabular component at a mean of 6-year follow-up","author":"Snijders","year":"2019","journal-title":"HSS J"},{"key":"10.1016\/j.otsr.2020.03.030_bib0300","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1097\/00003086-197611000-00003","article-title":"Radiological demarcation of cemented sockets in total hip replacement","volume":"121","author":"DeLee","year":"1976","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2020.03.030_bib0305","first-page":"6","article-title":"The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis","volume":"90","author":"Glyn-Jones","year":"2008","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.otsr.2020.03.030_bib0310","series-title":"The RM Cup \u2013 long-term experience with an elastic monobloc acetabular implant","first-page":"16","article-title":"Biomechanical principles and studies","author":"Gasser","year":"2008"},{"key":"10.1016\/j.otsr.2020.03.030_bib0315","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1302\/0301-620X.90B10.20274","article-title":"The results of the titanium-coated RM acetabular component at 20 years","volume":"90","author":"Ihle","year":"2008","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.otsr.2020.03.030_bib0320","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1080\/17453674.2016.1237439","article-title":"Cancellous and cortical bone mineral density around an elastic press-fit socket in total hip arthroplasty","volume":"87","author":"Pakvis","year":"2016","journal-title":"Acta Orthop"},{"key":"10.1016\/j.otsr.2020.03.030_bib0325","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/j.arth.2014.11.017","article-title":"An uncemented iso-elastic monoblock acetabular component: preliminary results","volume":"30","author":"Halma","year":"2015","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2020.03.030_bib0330","article-title":"Survival of monoblock RM vitamys compared with modular PINNACLE cups: mid-term outcomes of 200 hips performed by a single surgeon","author":"Kenanidis","year":"2019","journal-title":"Hip Int"},{"key":"10.1016\/j.otsr.2020.03.030_bib0335","first-page":"2323","article-title":"Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty","volume":"87","author":"McCalden","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2020.03.030_bib0340","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1054\/arth.2002.34530","article-title":"Precision of EBRA-digital software for monitoring implant migration after total hip arthroplasty","volume":"17","author":"Wilkinson","year":"2002","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2020.03.030_bib0345","doi-asserted-by":"crossref","first-page":"107","DOI":"10.2106\/JBJS.16.01379","article-title":"Creep and wear in vitamin E-infused highly cross-linked polyethylene cups for total hip arthroplasty: a prospective randomised controlled trial","volume":"100","author":"Rochcongar","year":"2018","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2020.03.030_bib0350","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1007\/s11999-012-2497-y","article-title":"The 2012 Frank-Stinchfield Award: decreasing patient activity with aging: implications for cross-linked polyethylene wear","volume":"471","author":"Battenberg","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.otsr.2020.03.030_bib0355","doi-asserted-by":"crossref","first-page":"1366","DOI":"10.2106\/JBJS.N.00595","article-title":"Femoral head penetration of vitamin E-infused highly cross-linked polyethylene liners: a randomised radiostereometric study of seventy hips followed for two years","volume":"97","author":"Shareghi","year":"2015","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2020.03.030_bib0360","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.arth.2007.03.009","article-title":"Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads","volume":"22","author":"Bragdon","year":"2007","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.otsr.2020.03.030_bib0365","doi-asserted-by":"crossref","first-page":"1786","DOI":"10.2106\/JBJS.15.01248","article-title":"The wear rate of highly cross-linked polyethylene in total hip replacement is not increased by large articulations: a randomised controlled trial","volume":"98","author":"Howie","year":"2016","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.otsr.2020.03.030_bib0370","doi-asserted-by":"crossref","first-page":"1260","DOI":"10.1016\/j.arth.2015.02.018","article-title":"Three year RSA evaluation of vitamin E diffused highly cross-linked polyethylene liners and cup stability","volume":"30","author":"Sillesen","year":"2015","journal-title":"J Arthroplasty"}],"container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056820301857?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056820301857?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T03:43:24Z","timestamp":1761795804000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1877056820301857"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["S1877056820301857"],"URL":"https:\/\/doi.org\/10.1016\/j.otsr.2020.03.030","relation":{},"ISSN":["1877-0568"],"issn-type":[{"value":"1877-0568","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Wear and migration are not influenced by head size in a vitamin E-infused highly cross-linked polyethylene acetabular cup","name":"articletitle","label":"Article Title"},{"value":"Orthopaedics & Traumatology: Surgery & Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.otsr.2020.03.030","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 The Authors. Published by Elsevier Masson SAS.","name":"copyright","label":"Copyright"}],"article-number":"102644"}}