{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T23:38:09Z","timestamp":1785281889981,"version":"3.55.0"},"reference-count":16,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"published-print":{"date-parts":[[2022,9]]},"DOI":"10.1016\/j.otsr.2022.103217","type":"journal-article","created":{"date-parts":[[2022,1,31]],"date-time":"2022-01-31T03:42:25Z","timestamp":1643600545000},"page":"103217","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"title":["User satisfaction with single-use instruments versus reusable instruments for treating distal radius fractures with locking volar plates"],"prefix":"10.1016","volume":"108","author":[{"given":"Romain","family":"Descl\u00e9e de Maredsous","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Soline","family":"Huet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sonia","family":"Brichoux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Louis","family":"Charissoux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre-Sylvain","family":"Marcheix","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.otsr.2022.103217_bib0085","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1186\/1471-2458-6-87","article-title":"Patients with femoral or distal forearm fracture in germany: A prospective observational study on health care situation and outcome","volume":"6","author":"Endres","year":"2006","journal-title":"BMC Public Health"},{"key":"10.1016\/j.otsr.2022.103217_bib0090","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1016\/j.jhsa.2011.05.017","article-title":"Current and future national costs to medicare for the treatment of distal radius fracture in the elderly","volume":"36","author":"Shauver","year":"2011","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.otsr.2022.103217_bib0095","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1016\/S0035-1040(06)75927-X","article-title":"plate fixation with locking screw for distal fractures of the radius","volume":"92","author":"Cognet","year":"2006","journal-title":"Rev Chir Orthop Reparatrice Appar Mot"},{"key":"10.1016\/j.otsr.2022.103217_bib0100","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1177\/1753193410364179","article-title":"Extension fractures of the distal radius in patients older than 50: A prospective randomized study comparing fixation using mixed pins or a palmar fixed-angle plate","volume":"35","author":"Marcheix","year":"2010","journal-title":"J Hand Surg Eur Vol"},{"key":"10.1016\/j.otsr.2022.103217_bib0105","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1302\/0301-620X.96B7.33149","article-title":"The operative treatment of fractures of the distal radius is increasing: Results from a nationwide swedish study","volume":"96\u2013B","author":"Mellstrand-Navarro","year":"2014","journal-title":"Bone Joint J"},{"key":"10.1016\/j.otsr.2022.103217_bib0110","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1055\/s-0033-1333664","article-title":"Single-use instrumentation, cutting blocks, and trials decrease contamination during total knee arthroplasty: a prospective comparison of navigated and nonnavigated cases","volume":"26","author":"Mont","year":"2013","journal-title":"J Knee Surg"},{"key":"10.1016\/j.otsr.2022.103217_bib0115","doi-asserted-by":"crossref","first-page":"930e1","DOI":"10.1016\/j.jhsa.2017.07.016","article-title":"Costs associated with single-use and conventional sets for distal radius plating","volume":"42","author":"Fugarino","year":"2017","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.otsr.2022.103217_bib0120","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1007\/s00590-019-02517-0","article-title":"Single-use versus reusable medical devices in spinal fusion surgery: A hospital micro-costing analysis","volume":"29","author":"Bouthors","year":"2019","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"10.1016\/j.otsr.2022.103217_bib0125","doi-asserted-by":"crossref","first-page":"H6","DOI":"10.1016\/S1877-0517(11)70003-X","article-title":"Principes et place des ancillaires \u00e0 usage unique dans les PTH","volume":"97","author":"Parratte","year":"2011","journal-title":"Revue de chirurgie orthop\u00e9dique et traumatologique"},{"key":"10.1016\/j.otsr.2022.103217_bib0130","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.pharma.2017.11.001","article-title":"perspective of the transition from reusable instruments to single use ancillary in orthopedic surgery","volume":"76","author":"Steelandt","year":"2018","journal-title":"Ann Pharm Fr"},{"key":"10.1016\/j.otsr.2022.103217_bib0135","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s13613-016-0228-3","article-title":"Cost analysis of single-use (ambu\u00ae aScope\u2122) and reusable bronchoscopes in the ICU","volume":"7","author":"Perbet","year":"2017","journal-title":"Ann Intensive Care"},{"key":"10.1016\/j.otsr.2022.103217_bib0140","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/S0016-5107(00)70351-8","article-title":"A performance, safety and cost comparison of reusable and disposable endoscopic biopsy forceps: a prospective, randomized trial","volume":"51","author":"Rizzo","year":"2000","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.otsr.2022.103217_bib0145","doi-asserted-by":"crossref","first-page":"353","DOI":"10.3389\/fpubh.2019.00353","article-title":"Employee acceptance of use: a precondition for enhancing therapy effectiveness, patient safety, and economic efficiency","volume":"7","author":"von Eiff","year":"2019","journal-title":"Front Public Health"},{"key":"10.1016\/j.otsr.2022.103217_bib0150","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1007\/s00464-003-9232-4","article-title":"Comparison of economic and environmental impacts between disposable and reusable instruments used for laparoscopic cholecystectomy","volume":"19","author":"Adler","year":"2005","journal-title":"Surg Endosc"},{"key":"10.1016\/j.otsr.2022.103217_bib0155","doi-asserted-by":"crossref","first-page":"104704","DOI":"10.1016\/j.resconrec.2020.104704","article-title":"Life cycle assessment of a disposable and a reusable surgery instrument set for spinal fusion surgeries","volume":"156","author":"Leiden","year":"2020","journal-title":"Resources, Conservation and Recycling"},{"key":"10.1016\/j.otsr.2022.103217_bib0160","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.injury.2013.10.003","article-title":"Complications after volar locking plate fixation of distal radius fractures","volume":"45","author":"Johnson","year":"2014","journal-title":"Injury"}],"container-title":["Orthopaedics &amp; Traumatology: Surgery &amp; Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056822000226?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1877056822000226?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T03:49:40Z","timestamp":1761796180000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1877056822000226"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9]]},"references-count":16,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,9]]}},"alternative-id":["S1877056822000226"],"URL":"https:\/\/doi.org\/10.1016\/j.otsr.2022.103217","relation":{},"ISSN":["1877-0568"],"issn-type":[{"value":"1877-0568","type":"print"}],"subject":[],"published":{"date-parts":[[2022,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"User satisfaction with single-use instruments versus reusable instruments for treating distal radius fractures with locking volar plates","name":"articletitle","label":"Article Title"},{"value":"Orthopaedics & Traumatology: Surgery & Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.otsr.2022.103217","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 Elsevier Masson SAS.","name":"copyright","label":"Copyright"}],"article-number":"103217"}}