{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T18:22:57Z","timestamp":1766168577101,"version":"3.48.0"},"reference-count":28,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T00:00:00Z","timestamp":1763683200000},"content-version":"vor","delay-in-days":51,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["phiro.science","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physics and Imaging in Radiation Oncology"],"published-print":{"date-parts":[[2025,10]]},"DOI":"10.1016\/j.phro.2025.100873","type":"journal-article","created":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T00:22:39Z","timestamp":1764202959000},"page":"100873","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Statistical process control for performance monitoring and continuous quality assurance of deep learning segmentations in radiotherapy"],"prefix":"10.1016","volume":"36","author":[{"given":"Niels","family":"van Acht","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dave","family":"van Gruijthuijsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johanna","family":"Bluemink","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Els","family":"Hagelaar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Coen","family":"Hurkmans","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.phro.2025.100873_b0005","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1007\/s00066-024-02262-2","article-title":"Deep learning for autosegmentation for radiotherapy treatment planning: State-of-the-art and novel perspectives","volume":"201","author":"Erdur","year":"2025","journal-title":"Strahlenther Onkol"},{"key":"10.1016\/j.phro.2025.100873_b0010","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.radonc.2022.05.018","article-title":"Training, validation, and clinical implementation of a deep-learning segmentation model for radiotherapy of loco-regional breast cancer","volume":"173","author":"Almberg","year":"2022","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.phro.2025.100873_b0015","doi-asserted-by":"crossref","first-page":"477","DOI":"10.2340\/1651-226X.2024.34986","article-title":"Comparison of the use of a clinically implemented deep learning segmentation model with the simulated study setting for breast cancer patients receiving radiotherapy","volume":"63","author":"Bakx","year":"2024","journal-title":"Acta Oncol"},{"key":"10.1016\/j.phro.2025.100873_b0020","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.14569","article-title":"Evaluating the dosimetric impact of deep-learning-based auto-segmentation in prostate cancer radiotherapy: Insights into real-world clinical implementation and inter-observer variability","volume":"26","author":"Arjmandi","year":"2025","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.phro.2025.100873_b0025","doi-asserted-by":"crossref","DOI":"10.3389\/fonc.2024.1375096","article-title":"Clinical validation of commercial deep-learning based auto-segmentation models for organs at risk in the head and neck region: a single institution study","volume":"14","author":"Johnson","year":"2024","journal-title":"Front Oncol"},{"key":"10.1016\/j.phro.2025.100873_b0030","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.radonc.2020.09.008","article-title":"Overview of artificial intelligence-based applications in radiotherapy: recommendations for implementation and quality assurance","volume":"153","author":"Vandewinckele","year":"2020","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.phro.2025.100873_b0035","doi-asserted-by":"crossref","first-page":"3679","DOI":"10.1109\/TMI.2020.3002417","article-title":"Optimization for medical image segmentation: theory and practice when evaluating with dice score or Jaccard Index","volume":"39","author":"Eelbode","year":"2020","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.phro.2025.100873_b0040","doi-asserted-by":"crossref","unstructured":"Nikolov S, Blackwell S, Zverovitch A, Mendes R, Livne M, De Fauw J, et al. Deep learning to achieve clinically applicable segmentation of head and neck anatomy for radiotherapy. Collection Deep learning to achieve clinically applicable segmentation of head and neck anatomy for radiotherapy 2021; Doi: 10.48550\/arXiv.1809.04430.","DOI":"10.2196\/preprints.26151"},{"key":"10.1016\/j.phro.2025.100873_b0045","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.phro.2019.11.006","article-title":"Deep learning-based auto-segmentation of targets and organs-at-risk for magnetic resonance imaging only planning of prostate radiotherapy","volume":"12","author":"Elguindi","year":"2019","journal-title":"Phys Imaging Radiat Oncol"},{"key":"10.1016\/j.phro.2025.100873_b0050","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1109\/34.232073","article-title":"Comparing images using the Hausdorff distance","volume":"15","author":"Huttenlocher","year":"1993","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"10.1016\/j.phro.2025.100873_b0055","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.phro.2019.12.001","article-title":"Evaluation of measures for assessing time-saving of automatic organ-at-risk segmentation in radiotherapy","volume":"13","author":"Vaassen","year":"2020","journal-title":"Phys Imaging Radiat Oncol"},{"key":"10.1016\/j.phro.2025.100873_b0060","article-title":"Clinical evaluation of a deep learning segmentation model including manual adjustments afterwards for locally advanced breast cancer","volume":"26","author":"Bakx","year":"2023","journal-title":"Tech Innov Patient Support Radiat Oncol"},{"key":"10.1016\/j.phro.2025.100873_b0065","unstructured":"Union E. Regulation (EU) 2024\/1689 of the European Parliament and of the Council of 15 October 2024 laying down harmonised rules on artificial intelligence and amending Regulations (Artificial Intelligence Act). https:\/\/eur-lex.europa.eu\/eli\/reg\/2024\/1689\/oj; 2024 [accessed 20 March 2025]."},{"key":"10.1016\/j.phro.2025.100873_b0070","doi-asserted-by":"crossref","DOI":"10.1016\/j.healthpol.2024.105152","article-title":"The EU Artificial Intelligence Act (2024): Implications for healthcare","volume":"149","author":"van Kolfschooten","year":"2024","journal-title":"Health Policy"},{"key":"10.1016\/j.phro.2025.100873_b0075","unstructured":"Union E. Obligations of Deployers of High-Risk AI Systems. https:\/\/artificialintelligenceact.eu\/article\/26\/; 2024 [accessed 20 March 2025]."},{"key":"10.1016\/j.phro.2025.100873_b0080","doi-asserted-by":"crossref","DOI":"10.1136\/bmj-2024-081554","article-title":"FUTURE-AI: international consensus guideline for trustworthy and deployable artificial intelligence in healthcare","volume":"388","author":"Lekadir","year":"2025","journal-title":"BMJ"},{"key":"10.1016\/j.phro.2025.100873_b0085","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1007\/s10916-021-01783-y","article-title":"Machine learning for health: algorithm auditing & quality control","volume":"45","author":"Oala","year":"2021","journal-title":"J Med Syst"},{"key":"10.1016\/j.phro.2025.100873_b0090","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20220878","article-title":"Data drift in medical machine learning: implications and potential remedies","volume":"96","author":"Sahiner","year":"2023","journal-title":"Br J Radiol"},{"key":"10.1016\/j.phro.2025.100873_b0095","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/j.ijrobp.2023.08.020","article-title":"Application and challenges of statistical process control in radiation therapy quality assurance","volume":"118","author":"Xiao","year":"2024","journal-title":"Int J Radiat Oncol* Biol* Phys"},{"key":"10.1016\/j.phro.2025.100873_b0100","doi-asserted-by":"crossref","first-page":"20","DOI":"10.11648\/j.sjams.20241202.11","article-title":"CPV monitoring - Optimization of Control Chart Design by reducing the False Alarm Rate and Nuisance Signal","volume":"12","author":"Muralidharan","year":"2024","journal-title":"Sci. J. Appl. Mathemat. Statist."},{"key":"10.1016\/j.phro.2025.100873_b0105","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1080\/00224065.1984.11978921","article-title":"The Shewhart Control Chart - Tests for special Causes","volume":"16","author":"Nelson","year":"1984","journal-title":"J Qual Technol"},{"key":"10.1016\/j.phro.2025.100873_b0110","article-title":"Large-scale dose evaluation of deep learning organ contours in head-and-neck radiotherapy by leveraging existing plans","volume":"30","author":"Mody","year":"2024","journal-title":"Phys Imaging Radiat Oncol"},{"key":"10.1016\/j.phro.2025.100873_b0115","doi-asserted-by":"crossref","DOI":"10.1016\/j.neuroimage.2023.120289","article-title":"ROOD-MRI: Benchmarking the robustness of deep learning segmentation models to out-of-distribution and corrupted data in MRI","volume":"278","author":"Boone","year":"2023","journal-title":"Neuroimage"},{"key":"10.1016\/j.phro.2025.100873_b0120","doi-asserted-by":"crossref","first-page":"2741","DOI":"10.1002\/mp.16846","article-title":"A quality assurance framework for routine monitoring of deep learning cardiac substructure computed tomography segmentation models in radiotherapy","volume":"51","author":"Jin","year":"2024","journal-title":"Med Phys"},{"key":"10.1016\/j.phro.2025.100873_b0125","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s41235-023-00529-3","article-title":"The impact of AI errors in a human-in-the-loop process","volume":"9","author":"Agudo","year":"2024","journal-title":"Cogn Res Princ Implic"},{"key":"10.1016\/j.phro.2025.100873_b0130","doi-asserted-by":"crossref","unstructured":"Roschewitz M, Mehta R, Jones C, Glocker B. Automatic dataset shift identification to support safe deployment of medical imaging AI. Collection Automatic dataset shift identification to support safe deployment of medical imaging AI 2025; Doi: 10.48550\/arXiv.2411.07940.","DOI":"10.1007\/978-3-032-04981-0_7"},{"key":"10.1016\/j.phro.2025.100873_b0135","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.70183","article-title":"Three discipline collaborative radiation therapy (3DCRT) special debate: AI structure segmentation is better than clinician contouring for both OARs and targets","volume":"26","author":"Hope","year":"2025","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.phro.2025.100873_b0140","article-title":"A geometry and dose-volume based performance monitoring of artificial intelligence models in radiotherapy treatment planning for prostate cancer","volume":"28","author":"De Kerf","year":"2023","journal-title":"Phys Imaging Radiat Oncol"}],"container-title":["Physics and Imaging in Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405631625001782?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405631625001782?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T18:18:55Z","timestamp":1766168335000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405631625001782"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":28,"alternative-id":["S2405631625001782"],"URL":"https:\/\/doi.org\/10.1016\/j.phro.2025.100873","relation":{},"ISSN":["2405-6316"],"issn-type":[{"type":"print","value":"2405-6316"}],"subject":[],"published":{"date-parts":[[2025,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Statistical process control for performance monitoring and continuous quality assurance of deep learning segmentations in radiotherapy","name":"articletitle","label":"Article Title"},{"value":"Physics and Imaging in Radiation Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.phro.2025.100873","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier B.V. on behalf of European Society of Radiotherapy & Oncology.","name":"copyright","label":"Copyright"}],"article-number":"100873"}}