{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T12:39:28Z","timestamp":1793104768558,"version":"4.5.0"},"reference-count":31,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T00:00:00Z","timestamp":1786579200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100007601","name":"Horizon 2020","doi-asserted-by":"publisher","award":["955956"],"award-info":[{"award-number":["955956"]}],"id":[{"id":"10.13039\/501100007601","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","phiro.science","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physics and Imaging in Radiation Oncology"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.phro.2026.101063","type":"journal-article","created":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T06:28:18Z","timestamp":1787552898000},"page":"101063","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["A novel approach for spot boosting selection and treatment plan optimization to enhance prompt gamma monitoring of proton therapy"],"prefix":"10.1016","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-5694-3250","authenticated-orcid":false,"given":"Beatrice","family":"Foglia","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-6739-0546","authenticated-orcid":false,"given":"Junjie","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-1355-4031","authenticated-orcid":false,"given":"Louna","family":"Chinaud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-9829-7381","authenticated-orcid":false,"given":"Albin","family":"Fredriksson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6750-4356","authenticated-orcid":false,"given":"Rasmus","family":"Nilsson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0486-6149","authenticated-orcid":false,"given":"Nicolas","family":"Depauw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Bortfeld","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9553-6024","authenticated-orcid":false,"given":"Guillaume","family":"Janssens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6835-2561","authenticated-orcid":false,"given":"Marco","family":"Pinto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7779-6690","authenticated-orcid":false,"given":"Katia","family":"Parodi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.phro.2026.101063_b1","doi-asserted-by":"crossref","first-page":"R99","DOI":"10.1088\/0031-9155\/57\/11\/R99","article-title":"Range uncertainties in proton therapy and the role of Monte Carlo simulations","volume":"57","author":"Paganetti","year":"2012","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b2","doi-asserted-by":"crossref","first-page":"R131","DOI":"10.1088\/0031-9155\/58\/15\/R131","article-title":"In vivo proton range verification: A review","volume":"58","author":"Knopf","year":"2013","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b3","doi-asserted-by":"crossref","first-page":"20190582","DOI":"10.1259\/bjr.20190582","article-title":"Myths and realities of range uncertainty","volume":"93","author":"Lomax","year":"2020","journal-title":"Brit J Radiol"},{"key":"10.1016\/j.phro.2026.101063_b4","doi-asserted-by":"crossref","first-page":"22TR01","DOI":"10.1088\/1361-6560\/ac344f","article-title":"Adaptive proton therapy","volume":"66","author":"Paganetti","year":"2021","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b5","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.semradonc.2017.11.005","article-title":"Robust proton treatment planning: Physical and biological optimization","volume":"28","author":"Unkelbach","year":"2018","journal-title":"Semin Radiat Oncol"},{"key":"10.1016\/j.phro.2026.101063_b6","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1088\/0031-9155\/42\/1\/008","article-title":"Adaptive radiation therapy","volume":"42","author":"Yan","year":"1997","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b7","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20190594","article-title":"Online daily adaptive proton therapy","volume":"93","author":"Albertini","year":"2020","journal-title":"Brit J Radiol"},{"key":"10.1016\/j.phro.2026.101063_b8","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ad7cbd","article-title":"First clinical implementation of a highly efficient daily online adapted proton therapy (DAPT) workflow","volume":"69","author":"Albertini","year":"2024","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b9","doi-asserted-by":"crossref","first-page":"5572","DOI":"10.1002\/mp.17178","article-title":"The partial adaptation strategy for online-adaptive proton therapy: A proof of concept study in head and neck cancer patients","volume":"51","author":"Gambetta","year":"2024","journal-title":"Med Phys"},{"key":"10.1016\/j.phro.2026.101063_b10","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.nima.2015.06.056","article-title":"On- and off-line monitoring of ion beam treatment","volume":"809","author":"Parodi","year":"2016","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"10.1016\/j.phro.2026.101063_b11","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.nima.2017.07.063","article-title":"Prompt-gamma monitoring in hadrontherapy: A review","volume":"878","author":"Krimmer","year":"2018","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"10.1016\/j.phro.2026.101063_b12","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1140\/epjp\/s13360-024-05664-4","article-title":"Prompt-gamma imaging in particle therapy","volume":"139","author":"Pinto","year":"2024","journal-title":"Eur Phys J Plus"},{"key":"10.1016\/j.phro.2026.101063_b13","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/acd834","article-title":"Range verification of a clinical proton beam in an abdominal phantom by co-registration of ionoacoustics and ultrasound","volume":"68","author":"Schauer","year":"2023","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b14","doi-asserted-by":"crossref","first-page":"e1036","DOI":"10.1002\/mp.12960","article-title":"In vivo range verification in particle therapy","volume":"45","author":"Parodi","year":"2018","journal-title":"Med Phys"},{"key":"10.1016\/j.phro.2026.101063_b15","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.ijrobp.2017.04.027","article-title":"Prompt Gamma imaging for in vivo range verification of pencil beam scanning proton therapy","volume":"99","author":"Xie","year":"2017","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.phro.2026.101063_b16","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20190619","article-title":"Prompt gamma imaging for the identification of regional proton range deviations due to anatomic change in a heterogeneous region","volume":"93","author":"Xie","year":"2020","journal-title":"Brit J Radiol"},{"key":"10.1016\/j.phro.2026.101063_b17","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/aae749","article-title":"Toward a new treatment planning approach accounting for in vivo proton range verification","volume":"63","author":"Tian","year":"2018","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b18","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ab7d15","article-title":"A new treatment planning approach accounting for prompt gamma range verification and interfractional anatomical changes","volume":"65","author":"Tian","year":"2020","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b19","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/abc939","article-title":"Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning","volume":"66","author":"Tian","year":"2021","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b20","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/S0167-8140(02)00308-0","article-title":"Intensity modulation in radiotherapy: Photons versus protons in the paranasal sinus","volume":"66","author":"Lomax","year":"2003","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.phro.2026.101063_b21","first-page":"4","article-title":"Intensity-modulated radiotherapy of nasopharyngeal carcinoma: A comparative treatment planning study of photons and protons","volume":"3","author":"Taheri-Kadkhoda","year":"2008","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.phro.2026.101063_b22","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/S0168-9002(03)01368-8","article-title":"Geant4 - A simulation toolkit","volume":"506","author":"Agostinelli","year":"2003","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"10.1016\/j.phro.2026.101063_b23","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1109\/TIT.1982.1056489","article-title":"Least squares quantization in PCM","volume":"28","author":"Lloyd","year":"1982","journal-title":"IEEE Trans Inform Theory"},{"key":"10.1016\/j.phro.2026.101063_b24","doi-asserted-by":"crossref","first-page":"225009","DOI":"10.1088\/1361-6560\/aae8a5","article-title":"LET-weighted doses effectively reduce biological variability in proton radiotherapy planning","volume":"63","author":"McMahon","year":"2018","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b25","doi-asserted-by":"crossref","first-page":"5849","DOI":"10.1088\/0031-9155\/59\/19\/5849","article-title":"Prompt gamma imaging of proton pencil beams at clinical dose rate","volume":"59","author":"Perali","year":"2014","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b26","doi-asserted-by":"crossref","first-page":"4915","DOI":"10.1088\/0031-9155\/60\/12\/4915","article-title":"Analytical computation of prompt gamma ray emission and detection for proton range verification","volume":"60","author":"Sterpin","year":"2015","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b27","doi-asserted-by":"crossref","first-page":"05RM01","DOI":"10.1088\/1361-6560\/abcd16","article-title":"Roadmap: Proton therapy physics and biology","volume":"66","author":"Paganetti","year":"2021","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b28","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.ijrobp.2015.01.031","article-title":"Shortening delivery times of intensity modulated proton therapy by reducing proton energy layers during treatment plan optimization","volume":"92","author":"Van De Water","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.phro.2026.101063_b29","doi-asserted-by":"crossref","first-page":"095008","DOI":"10.1088\/1361-6560\/ab7e7c","article-title":"Shortening delivery times for intensity-modulated proton therapy by reducing the number of proton spots: An experimental verification","volume":"65","author":"Van De Water","year":"2020","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.phro.2026.101063_b30","doi-asserted-by":"crossref","first-page":"25","DOI":"10.3390\/instruments2040025","article-title":"Correction of geometrical effects of a knife-edge slit camera for prompt gamma-based range verification in proton therapy","volume":"2","author":"Petzoldt","year":"2018","journal-title":"Instruments"},{"key":"10.1016\/j.phro.2026.101063_b31","doi-asserted-by":"crossref","first-page":"115009","DOI":"10.1088\/1361-6560\/acd237","article-title":"Analytical modeling and Monte Carlo simulations of multi-parallel slit and knife-edge slit prompt gamma cameras","volume":"68","author":"Huisman","year":"2023","journal-title":"Phys Med Biol"}],"container-title":["Physics and Imaging in Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405631626001636?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405631626001636?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T12:28:11Z","timestamp":1793104091000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405631626001636"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":31,"alternative-id":["S2405631626001636"],"URL":"https:\/\/doi.org\/10.1016\/j.phro.2026.101063","relation":{},"ISSN":["2405-6316"],"issn-type":[{"value":"2405-6316","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A novel approach for spot boosting selection and treatment plan optimization to enhance prompt gamma monitoring of proton therapy","name":"articletitle","label":"Article Title"},{"value":"Physics and Imaging in Radiation Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.phro.2026.101063","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier B.V. on behalf of European Society of Radiotherapy & Oncology.","name":"copyright","label":"Copyright"}],"article-number":"101063"}}