{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T21:38:46Z","timestamp":1769377126686,"version":"3.49.0"},"reference-count":23,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2020,10,1]],"date-time":"2020-10-01T00:00:00Z","timestamp":1601510400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,10,1]],"date-time":"2020-10-01T00:00:00Z","timestamp":1601510400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"name":"Jiangsu Provincial Key Medical Talents Project","award":["ZDRCC2016017"],"award-info":[{"award-number":["ZDRCC2016017"]}]},{"name":"Nanjing Medical Science and Technique Development Foundation","award":["QXR17175"],"award-info":[{"award-number":["QXR17175"]}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2020,10]]},"DOI":"10.1016\/j.prosdent.2019.10.020","type":"journal-article","created":{"date-parts":[[2019,12,24]],"date-time":"2019-12-24T00:05:05Z","timestamp":1577145905000},"page":"495-499","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":20,"title":["A speech bulb prosthesis for a soft palate defect with a polyetherketoneketone (PEKK) framework fabricated by multiple digital techniques: A clinical report"],"prefix":"10.1016","volume":"124","author":[{"given":"Fangfang","family":"Sun","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Shen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nan","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yalin","family":"Guo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaojing","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guofeng","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2019.10.020_bib1","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.dental.2013.12.008","article-title":"Resin bonding to three types of polyaryletherketones (PAEKs)-durability and influence of surface conditioning","volume":"30","author":"Fuhrmann","year":"2014","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2019.10.020_bib2","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1016\/j.prosdent.2016.08.009","article-title":"Using modified polyetheretherketone (PEEK) as an alternative material for endocrown restorations: A short-term clinical report","volume":"117","author":"Zoidis","year":"2017","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2019.10.020_bib3","doi-asserted-by":"crossref","first-page":"80","DOI":"10.4103\/0972-4052.197941","article-title":"Versatility of PEEK as a fixed partial denture framework","volume":"17","author":"Sinha","year":"2017","journal-title":"J\u00a0Indian Prosthodont Soc"},{"key":"10.1016\/j.prosdent.2019.10.020_bib4","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.prosdent.2016.04.024","article-title":"Modified PEEK resin-bonded fixed dental prosthesis as an interim restoration after implant placement","volume":"116","author":"Zoidis","year":"2016","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2019.10.020_bib5","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1111\/jerd.12221","article-title":"Modified PEEK resin bonded fixed dental prosthesis for a young cleft lip and palate patient","volume":"28","author":"Andrikopoulou","year":"2016","journal-title":"J\u00a0Esthet Restor Dent"},{"key":"10.1016\/j.prosdent.2019.10.020_bib6","first-page":"37","article-title":"Modified PEEK as an alternative crown framework material for weak abutment teeth: a case report","volume":"65","author":"Zoidis","year":"2017","journal-title":"Gen Dent"},{"key":"10.1016\/j.prosdent.2019.10.020_bib7","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1111\/jopr.12325","article-title":"The use of a modified poly-ether-ether-ketone (PEEK) as an alternative framework material for removable dental prostheses. A clinical report","volume":"25","author":"Zoidis","year":"2016","journal-title":"J\u00a0Prosthodont"},{"key":"10.1016\/j.prosdent.2019.10.020_bib8","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/j.prosdent.2017.02.017","article-title":"Interim rehabilitation of occlusal vertical dimension using a double-crown-retained removable dental prosthesis with polyetheretherketone framework","volume":"119","author":"Hahnel","year":"2018","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2019.10.020_bib9","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1016\/j.prosdent.2013.10.026","article-title":"Use of polyetheretherketone in the fabrication of a maxillary obturator prosthesis: a clinical report","volume":"112","author":"Costa-Palau","year":"2014","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2019.10.020_bib10","first-page":"19","article-title":"A\u00a0review of PEEK polymer's properties and its use in prosthodontics","volume":"19","author":"Skirbutis","year":"2017","journal-title":"Stomatologija"},{"key":"10.1016\/j.prosdent.2019.10.020_bib11","doi-asserted-by":"crossref","first-page":"4","DOI":"10.11607\/ijp.4688","article-title":"Implant- and tooth-supported fixed prostheses using a high-performance polymer (Pekkton) framework","volume":"29","author":"Han","year":"2016","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2019.10.020_bib12","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.3109\/00016357.2012.757644","article-title":"Effect of framework material and vertical misfit on stress distribution in implant-supported partial prosthesis under load application: 3-D finite element analysis","volume":"71","author":"Bacchi","year":"2013","journal-title":"Acta Odontol Scand"},{"key":"10.1016\/j.prosdent.2019.10.020_bib13","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1016\/j.prosdent.2017.09.008","article-title":"Polyetherketoneketone (PEKK), a framework material for complete fixed and removable dental prostheses: a clinical report","volume":"119","author":"Dawson","year":"2018","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2019.10.020_bib14","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jpor.2015.10.001","article-title":"Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics","volume":"60","author":"Najeeb","year":"2016","journal-title":"J\u00a0Prosthodont Res"},{"key":"10.1016\/j.prosdent.2019.10.020_bib15","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1016\/j.prosdent.2017.04.017","article-title":"Accuracy of CAD-CAM-fabricated removable partial dentures","volume":"119","author":"Arnold","year":"2018","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2019.10.020_bib16","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1007\/s00784-012-0864-4","article-title":"Accuracy of digital and conventional impression techniques and workflow","volume":"17","author":"Seelbach","year":"2013","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2019.10.020_bib17","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.prosdent.2014.09.027","article-title":"Comparison of accuracy and reproducibility of casts made by digital and conventional methods","volume":"113","author":"Cho","year":"2015","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2019.10.020_bib18","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.prosdent.2015.09.011","article-title":"In\u00a0vivo precision of conventional and digital methods of obtaining complete-arch dental impressions","volume":"115","author":"Ender","year":"2016","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2019.10.020_bib19","first-page":"138","article-title":"Clinical performance of cast clasp-retained removable partial dentures: a retrospective study","volume":"25","author":"Behr","year":"2012","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2019.10.020_bib20","first-page":"551","article-title":"Esthetic considerations with removable partial dentures","volume":"31","author":"Donovan","year":"2003","journal-title":"J\u00a0Calif Dent Assoc"},{"key":"10.1016\/j.prosdent.2019.10.020_bib21","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.dental.2011.10.016","article-title":"Retentive forces and fatigue resistance of thermoplastic resin clasps","volume":"28","author":"Tannous","year":"2012","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2019.10.020_bib22","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/S0109-5641(98)00007-4","article-title":"Design of prosthetic cantilever bridgework supported by osseointegrated implants using the finite element method","volume":"14","author":"Young","year":"1998","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2019.10.020_bib23","doi-asserted-by":"crossref","first-page":"E4","DOI":"10.3390\/dj7010004","article-title":"Use of a polyetheretherketone clasp retainer for removable partial denture: a case report","volume":"7","author":"Ichikawa","year":"2019","journal-title":"Dent J (Basel)"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391319307000?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391319307000?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T10:55:28Z","timestamp":1758365728000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391319307000"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["S0022391319307000"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2019.10.020","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2020,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A speech bulb prosthesis for a soft palate defect with a polyetherketoneketone (PEKK) framework fabricated by multiple digital techniques: A clinical report","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2019.10.020","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 by the Editorial Council for The Journal of Prosthetic Dentistry.","name":"copyright","label":"Copyright"}]}}