{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T00:40:45Z","timestamp":1792629645832,"version":"4.5.0"},"reference-count":46,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T00:00:00Z","timestamp":1646092800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T00:00:00Z","timestamp":1646092800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2022,3]]},"DOI":"10.1016\/j.prosdent.2020.09.033","type":"journal-article","created":{"date-parts":[[2020,12,10]],"date-time":"2020-12-10T03:54:20Z","timestamp":1607572460000},"page":"470-476","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":34,"title":["In\u00a0vitro assessment of PEEK and titanium implant abutments: Screw loosening and microleakage evaluations under dynamic mechanical testing"],"prefix":"10.1016","volume":"127","author":[{"given":"Jordi","family":"Ortega-Mart\u00ednez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luis M.","family":"Delgado","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M\u00f3nica","family":"Ortiz-Hern\u00e1ndez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miquel","family":"Punset","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jordi","family":"Cano-Batalla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miguel Roig","family":"Cayon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josep","family":"Cabratosa-Termes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2020.09.033_bib1","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/0022-3913(89)90081-4","article-title":"Criteria for success of osseointegrated endosseous implants","volume":"62","author":"Smith","year":"1989","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.09.033_bib2","first-page":"197","article-title":"The longitudinal clinical effectiveness of osseointegrated dental implants for single-tooth replacement","volume":"6","author":"Schmitt","year":"1993","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2020.09.033_bib3","first-page":"1","article-title":"Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period","volume":"11","author":"Br\u00e5nemark","year":"1977","journal-title":"Scand J Plast Reconstr Surg Hand Surg"},{"key":"10.1016\/j.prosdent.2020.09.033_bib4","first-page":"54","article-title":"Comparison of early bacterial colonization of PEEK and titanium healing abutments using real-time PCR","volume":"6","author":"Volpe","year":"2008","journal-title":"Applied Osseointegration Research"},{"key":"10.1016\/j.prosdent.2020.09.033_bib5","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1563\/AAID-JOI-D-11-00002","article-title":"PEEK dental implants: a review of the literature","volume":"39","author":"Schwitalla","year":"2013","journal-title":"J\u00a0Oral Implantol"},{"key":"10.1016\/j.prosdent.2020.09.033_bib6","doi-asserted-by":"crossref","first-page":"155","DOI":"10.3109\/17453678108991776","article-title":"Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man","volume":"52","author":"Albrektsson","year":"1981","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.prosdent.2020.09.033_bib7","doi-asserted-by":"crossref","first-page":"5426","DOI":"10.3390\/ijms15045426","article-title":"Current strategies to improve the bioactivity of PEEK","volume":"15","author":"Ma","year":"2014","journal-title":"Int J Mol Sci"},{"key":"10.1016\/j.prosdent.2020.09.033_bib8","first-page":"448","article-title":"High-Performance Polymers and Their Potential Application as Medical and Oral Implant Materials: A Review","volume":"24","author":"Wiesli","year":"2015","journal-title":"Implant Dent"},{"key":"10.1016\/j.prosdent.2020.09.033_bib9","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1111\/j.1600-0501.2009.01785.x","article-title":"Are ceramic implants a viable alternative to titanium implants? A systematic literature review","volume":"20","author":"Andreiotelli","year":"2009","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2020.09.033_bib10","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1002\/jbm.b.32669","article-title":"Stress shielding and fatigue limits of polyetheretherketone dental implants","volume":"100","author":"Lee","year":"2012","journal-title":"J\u00a0Biomed Mater Res B Appl Biomater"},{"key":"10.1016\/j.prosdent.2020.09.033_bib11","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.prosdent.2017.03.008","article-title":"Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: A three-dimensional finite element analysis study","volume":"119","author":"Kaleli","year":"2018","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.09.033_bib12","doi-asserted-by":"crossref","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","article-title":"PEEK biomaterials in trauma, orthopedic, and spinal implants","volume":"28","author":"Kurtz","year":"2007","journal-title":"Biomaterials"},{"key":"10.1016\/j.prosdent.2020.09.033_bib13","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.jmbbm.2015.12.038","article-title":"Comparison between PEEK and Ti6Al4V concerning micro-scale abrasion wear on dental applications","volume":"60","author":"Sampaio","year":"2016","journal-title":"J\u00a0Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2020.09.033_bib14","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1016\/j.dental.2015.08.151","article-title":"Flexural behavior of PEEK materials for dental application","volume":"31","author":"Schwitalla","year":"2015","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2020.09.033_bib15","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.jmbbm.2016.12.019","article-title":"Fatigue limits of different PEEK materials for dental implants","volume":"69","author":"Schwitalla","year":"2017","journal-title":"J\u00a0Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2020.09.033_bib16","doi-asserted-by":"crossref","first-page":"1209","DOI":"10.1002\/jbm.b.32932","article-title":"Polyetheretherketone\u2014a suitable material for fixed dental prostheses?","volume":"101","author":"Stawarczyk","year":"2013","journal-title":"J\u00a0Biomed Mater Res B Appl Biomater"},{"key":"10.1016\/j.prosdent.2020.09.033_bib17","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jpor.2015.10.001","article-title":"Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics","volume":"60","author":"Najeeb","year":"2016","journal-title":"J\u00a0Prosthodont Res"},{"key":"10.1016\/j.prosdent.2020.09.033_bib18","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10856-016-5731-4","article-title":"Polyetheretherketone (PEEK) for medical applications","volume":"27","author":"Panayotov","year":"2016","journal-title":"J\u00a0Mater Sci Mater Med"},{"key":"10.1016\/j.prosdent.2020.09.033_bib19","first-page":"14","article-title":"A\u00a0polyaryletherketone biomaterial for use in medical implant applications","author":"Green","year":"2001","journal-title":"Polym for the Med Ind Proc"},{"key":"10.1016\/j.prosdent.2020.09.033_bib20","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1097\/ID.0b013e318167648c","article-title":"A\u00a0new transitional abutment for immediate aesthetics and function","volume":"17","author":"Tetelman","year":"2008","journal-title":"Implant Dent"},{"key":"10.1016\/j.prosdent.2020.09.033_bib21","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1007\/s00784-016-1892-2","article-title":"Discoloration of PMMA, composite, and PEEK","volume":"21","author":"Heimer","year":"2017","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2020.09.033_bib22","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1590\/1807-3107BOR-2014.vol28.0028","article-title":"Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone","volume":"28","author":"Neumann","year":"2014","journal-title":"Braz Oral Res"},{"key":"10.1016\/j.prosdent.2020.09.033_bib23","doi-asserted-by":"crossref","first-page":"2079","DOI":"10.1007\/s10856-010-4084-7","article-title":"Evaluation of the stress distribution in CFR-PEEK dental implants by the three-dimensional finite element method","volume":"21","author":"Sarot","year":"2010","journal-title":"J\u00a0Mater Sci Mater Med"},{"key":"10.1016\/j.prosdent.2020.09.033_bib24","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1177\/0954411914538783","article-title":"The influence of nominal stress on wear factors of carbon fibre\u2013reinforced polyetheretherketone (PEEK-OPTIMA Wear Performance) against zirconia toughened alumina (Biolox delta ceramic)","volume":"228","author":"Evans","year":"2014","journal-title":"Proc Inst Mech Eng Part H J Eng Med"},{"key":"10.1016\/j.prosdent.2020.09.033_bib25","doi-asserted-by":"crossref","first-page":"94","DOI":"10.4317\/medoral.19958","article-title":"Mechanical behavior of provisional implant prosthetic abutments","volume":"20","author":"Agustin-Panadero","year":"2015","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"10.1016\/j.prosdent.2020.09.033_bib26","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1016\/j.prosdent.2013.10.026","article-title":"Use of polyetheretherketone in the fabrication of a maxillary obturator prosthesis: a clinical report","volume":"112","author":"Costa-Palau","year":"2014","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.09.033_bib27","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1016\/j.prosdent.2017.04.020","article-title":"The all-on-4 modified polyetheretherketone treatment approach: A clinical report","volume":"119","author":"Zoidis","year":"2018","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.09.033_bib28","doi-asserted-by":"crossref","first-page":"21","DOI":"10.4047\/jap.2013.5.1.21","article-title":"Influence of the implant abutment types and the dynamic loading on initial screw loosening","volume":"5","author":"Kim","year":"2013","journal-title":"J\u00a0Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2020.09.033_bib29","doi-asserted-by":"crossref","first-page":"350","DOI":"10.11607\/jomi.5295","article-title":"An in\u00a0vitro evaluation of the loosening of different interchangeable abutments in internal-connection-type implants","volume":"32","author":"Park","year":"2017","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2020.09.033_bib30","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1016\/j.prosdent.2014.06.002","article-title":"Accuracy and precision of as-received implant torque wrenches","volume":"112","author":"Britton-Vidal","year":"2014","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.09.033_bib31","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1016\/j.prosdent.2016.03.012","article-title":"In\u00a0vitro assessment of the marginal and internal fits of interim implant restorations fabricated with different methods","volume":"116","author":"Park","year":"2016","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.09.033_bib32","first-page":"793","article-title":"Influence of methodologic aspects on the results of implant-abutment interface microleakage tests: a critical review of in\u00a0vitro studies","volume":"27","author":"Paulo da Silva-Neto","year":"2012","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2020.09.033_bib33","first-page":"875","article-title":"In\u00a0vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems","volume":"20","author":"Steinebrunner","year":"2005","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2020.09.033_bib34","doi-asserted-by":"crossref","first-page":"103","DOI":"10.11607\/jomi.2443","article-title":"Mechanical testing of implant-supported anterior crowns with different implant\/abutment connections","volume":"28","author":"Almeida","year":"2013","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2020.09.033_bib35","series-title":"ISO 14801 Dentistry\u2013Implants-Dynamic loading test for endosseous dental implants","year":"2016"},{"key":"10.1016\/j.prosdent.2020.09.033_bib36","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1016\/j.dental.2008.09.010","article-title":"In\u00a0vitro evaluation of a mechanical testing chewing simulator","volume":"25","author":"Steiner","year":"2008","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2020.09.033_bib37","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.11607\/jomi.3694","article-title":"Displacement of implant abutments following initial and repeated torqueing","volume":"30","author":"Yilmaz","year":"2015","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2020.09.033_bib38","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1563\/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2","article-title":"The relationship between implant preload and screw loosening on implant-supported prostheses","volume":"28","author":"Siamos","year":"2002","journal-title":"J\u00a0Oral Implantol"},{"key":"10.1016\/j.prosdent.2020.09.033_bib39","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1563\/aaid-joi-D-16-00065","article-title":"A\u00a0novel approach to prove bacterial leakage of implant-abutment connections in\u00a0vitro","volume":"42","author":"Wachtel","year":"2016","journal-title":"J\u00a0Oral Implantol"},{"key":"10.1016\/j.prosdent.2020.09.033_bib40","first-page":"1","article-title":"Leakage evaluation of original and compatible implant-abutment connections: In\u00a0vitro study using Rhodamine B","volume":"5","author":"Berberi","year":"2014","journal-title":"J\u00a0Dent Biomech"},{"key":"10.1016\/j.prosdent.2020.09.033_bib41","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.1111\/clr.12217","article-title":"Microleakage of the prosthetic abutment\/implant interface with internal and external connection: In\u00a0vitro study","volume":"25","author":"Larrucea Verdugo","year":"2014","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2020.09.033_bib42","first-page":"1146","article-title":"Fluids and microbial penetration in the internal part of cement-retained versus screw-retained implant-abutment connections","volume":"72","author":"Piattelli","year":"2001","journal-title":"J\u00a0Periodontol"},{"key":"10.1016\/j.prosdent.2020.09.033_bib43","first-page":"19","article-title":"Zirconium implant abutments: fracture strength and influence of cyclic loading on retaining-screw loosening","volume":"37","author":"Gehrke","year":"2006","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2020.09.033_bib44","first-page":"293","article-title":"Bite force in subjects with complete dentition","volume":"26","author":"\u017divko-Babi\u0107","year":"2002","journal-title":"Coll Antropol"},{"key":"10.1016\/j.prosdent.2020.09.033_bib45","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/j.ijfatigue.2015.08.022","article-title":"Cyclic deformation and fatigue behavior of polyether ether ketone (PEEK)","volume":"82","author":"Shrestha","year":"2016","journal-title":"Int J Fatigue"},{"key":"10.1016\/j.prosdent.2020.09.033_bib46","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/j.jmbbm.2015.07.020","article-title":"Effects of microstructural inclusions on fatigue life of polyether ether ketone (PEEK)","volume":"51","author":"Simsiriwong","year":"2015","journal-title":"J\u00a0Mech Behav Biomed Mater"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391320306879?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391320306879?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T10:58:01Z","timestamp":1758365881000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391320306879"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3]]},"references-count":46,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,3]]}},"alternative-id":["S0022391320306879"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2020.09.033","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2022,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"In\u00a0vitro assessment of PEEK and titanium implant abutments: Screw loosening and microleakage evaluations under dynamic mechanical testing","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2020.09.033","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 by the Editorial Council for the Journal of Prosthetic Dentistry.","name":"copyright","label":"Copyright"}]}}