{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T19:46:00Z","timestamp":1786995960003,"version":"build-2736575974"},"reference-count":37,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T00:00:00Z","timestamp":1648771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T00:00:00Z","timestamp":1648771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100004663","name":"Ministry of Science and Technology, Taiwan","doi-asserted-by":"publisher","award":["107-2221-E-006-052-MY2"],"award-info":[{"award-number":["107-2221-E-006-052-MY2"]}],"id":[{"id":"10.13039\/501100004663","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2022,4]]},"DOI":"10.1016\/j.prosdent.2020.10.022","type":"journal-article","created":{"date-parts":[[2020,12,18]],"date-time":"2020-12-18T20:28:12Z","timestamp":1608323292000},"page":"601-608","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Biomechanical analysis of the press-fit effect in a conical Morse taper implant system by using an in\u00a0vitro experimental test and finite element analysis"],"prefix":"10.1016","volume":"127","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0351-7414","authenticated-orcid":false,"given":"Hung-Chih","family":"Chang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chih-Han","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hung-Yuan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chau-Hsiang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2020.10.022_bib1","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1034\/j.1600-0501.1997.080509.x","article-title":"Some clinical and radiographical features of submerged and non-submerged titanium implants. A 5-year follow-up study","volume":"8","author":"Ericsson","year":"1997","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2020.10.022_bib2","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1111\/j.1600-051X.2004.00527.x","article-title":"Submerged or non-submerged healing of endosseous implants to be used in the rehabilitation of partially dentate patients","volume":"31","author":"Cecchinato","year":"2004","journal-title":"J\u00a0Clin Periodontol"},{"key":"10.1016\/j.prosdent.2020.10.022_bib3","doi-asserted-by":"crossref","first-page":"e40","DOI":"10.1590\/1807-3107BOR-2016.vol30.0040","article-title":"Effects of different torque levels on the implant-abutment interface in a conical internal connection","volume":"30","author":"Gehrke","year":"2016","journal-title":"Braz Oral Res"},{"key":"10.1016\/j.prosdent.2020.10.022_bib4","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0022-3913(03)00212-9","article-title":"Clinical complications with implants and implant prostheses","volume":"90","author":"Goodacre","year":"2003","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.10.022_bib5","doi-asserted-by":"crossref","first-page":"505","DOI":"10.11607\/jomi.5836","article-title":"Association between implant-abutment microgap and implant circularity to bacterial leakage: an in\u00a0vitro study using tapered connection implants","volume":"33","author":"Lopes de Chaves E Mello Dias","year":"2018","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2020.10.022_bib6","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1111\/cid.12219","article-title":"The potential risk of conical implant-abutment connections: the antirotational ability of cowell implant system","volume":"17","author":"Yao","year":"2015","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2020.10.022_bib7","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1177\/154405910308200316","article-title":"Persistent acute inflammation at the implant-abutment interface","volume":"82","author":"Broggini","year":"2003","journal-title":"J\u00a0Dent Res"},{"key":"10.1016\/j.prosdent.2020.10.022_bib8","first-page":"409","article-title":"The new restorative concept of the ITI dental implant system: design and engineering","volume":"13","author":"Sutter","year":"1993","journal-title":"Int J Periodontics Restorative Dent"},{"key":"10.1016\/j.prosdent.2020.10.022_bib9","first-page":"2491714","article-title":"Peri-implant bone loss and peri-implantitis: a report of three cases and review of the literature","volume":"2016","author":"John","year":"2016","journal-title":"Case Rep Dent"},{"key":"10.1016\/j.prosdent.2020.10.022_bib10","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1111\/jcpe.12369","article-title":"Primary prevention of peri-implantitis: managing peri-implant mucositis","volume":"42","author":"Jepsen","year":"2015","journal-title":"J\u00a0Clin Periodontol"},{"key":"10.1016\/j.prosdent.2020.10.022_bib11","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.1111\/clr.12217","article-title":"Microleakage of the prosthetic abutment\/implant interface with internal and external connection: in\u00a0vitro study","volume":"25","author":"Verdugo","year":"2014","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2020.10.022_bib12","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1097\/ID.0b013e3182943062","article-title":"Microbiological evaluation of bacterial and mycotic seal in implant systems with different implant-abutment interfaces and closing torque values","volume":"22","author":"Baggi","year":"2013","journal-title":"Implant Dent"},{"key":"10.1016\/j.prosdent.2020.10.022_bib13","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1034\/j.1600-0501.2000.011S1022.x","article-title":"The development of the ITI dental implant system. Part 2: 1998-2000: steps into the next millennium","volume":"11","author":"Scacchi","year":"2000","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2020.10.022_bib14","series-title":"Principles and design of mechanical face seals","first-page":"232","author":"Lebeck","year":"1991"},{"key":"10.1016\/j.prosdent.2020.10.022_bib15","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1016\/S0021-9290(03)00177-5","article-title":"Mechanics of the tapered interference fit in dental implants","volume":"36","author":"Bozkaya","year":"2003","journal-title":"J\u00a0Biomech"},{"key":"10.1016\/j.prosdent.2020.10.022_bib16","first-page":"732","article-title":"In\u00a0vitro evaluation of the implant-abutment bacterial seal: the locking taper system","volume":"20","author":"Dibart","year":"2005","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2020.10.022_bib17","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/s10856-017-5879-6","article-title":"Wear of Morse taper and external hexagon implant joints after abutment removal","volume":"28","author":"Prado","year":"2017","journal-title":"J\u00a0Mater Sci"},{"key":"10.1016\/j.prosdent.2020.10.022_bib18","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1016\/j.dental.2012.08.008","article-title":"Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in\u00a0vitro study","volume":"28","author":"Stimmelmayr","year":"2012","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2020.10.022_bib19","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1186\/s13104-018-3635-8","article-title":"Sphere-plane methodology to evaluate the wear of titanium of dental implants: a research proposal","volume":"11","author":"Mendes","year":"2018","journal-title":"BMC Res Notes"},{"key":"10.1016\/j.prosdent.2020.10.022_bib20","doi-asserted-by":"crossref","first-page":"423","DOI":"10.4047\/jap.2015.7.6.423","article-title":"Long-term cumulative survival and mechanical complications of single-tooth Ankylos implants: focus on the abutment neck fractures","volume":"7","author":"Shim","year":"2015","journal-title":"J\u00a0Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2020.10.022_bib21","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1111\/j.1600-0501.2007.01453.x","article-title":"A\u00a0systematic review of the 5-year survival and complication rates of implant-supported single crowns","volume":"19","author":"Jung","year":"2008","journal-title":"Clin Oral Implant Res"},{"key":"10.1016\/j.prosdent.2020.10.022_bib22","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1111\/j.1600-0501.2007.01414.x","article-title":"Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years","volume":"18","author":"Kreissl","year":"2007","journal-title":"Clin Oral Implant Res"},{"key":"10.1016\/j.prosdent.2020.10.022_bib23","doi-asserted-by":"crossref","first-page":"e197","DOI":"10.1016\/j.dental.2018.04.005","article-title":"Fracture loads and failure modes of customized and non-customized zirconia abutments","volume":"34","author":"Moris","year":"2018","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2020.10.022_bib24","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1563\/AAID-JOI-D-09-00135.1","article-title":"Osseointegrated implant fracture: causes and treatment","volume":"37","author":"Gealh","year":"2011","journal-title":"J\u00a0Oral Implantol"},{"key":"10.1016\/j.prosdent.2020.10.022_bib25","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1111\/j.1600-0501.2004.01059.x","article-title":"Predicting osseointegration by means of implant primary stability","volume":"15","author":"Nedir","year":"2004","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2020.10.022_bib26","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1001\/archopht.1991.01080070144054","article-title":"The osseointegration technique for the rehabilitation of the exenterated orbit","volume":"109","author":"Nerad","year":"1991","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.prosdent.2020.10.022_bib27","doi-asserted-by":"crossref","first-page":"567","DOI":"10.11607\/jomi.7106","article-title":"Performance of a repair service set for the retrieval of fractured abutment screws: a pilot in\u00a0vitro study","volume":"34","author":"Igarashi","year":"2019","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2020.10.022_bib28","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1563\/AAID-JOI-D-10-00162","article-title":"A\u00a0modified technique for removing a failed abutment screw from an implant with a custom guide tube","volume":"38","author":"Taira","year":"2012","journal-title":"J\u00a0Oral Implantol"},{"key":"10.1016\/j.prosdent.2020.10.022_bib29","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1016\/j.dental.2018.06.002","article-title":"Fatigue lifetime prediction of a reduced-diameter dental implant system: numerical and experimental study","volume":"34","author":"Duan","year":"2018","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2020.10.022_bib30","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/1746-160X-8-18","article-title":"Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis","volume":"8","author":"Frisardi","year":"2012","journal-title":"Head Face Med"},{"key":"10.1016\/j.prosdent.2020.10.022_bib31","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1563\/1548-1336(1998)024<0080:EPOODI>2.3.CO;2","article-title":"Evaluating parameters of osseointegrated dental implants using finite element analysis-a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction","volume":"24","author":"Holmgren","year":"1998","journal-title":"J\u00a0Oral Implantol"},{"key":"10.1016\/j.prosdent.2020.10.022_bib32","doi-asserted-by":"crossref","first-page":"388","DOI":"10.4047\/jap.2016.8.5.388","article-title":"Influence of the connection design and titanium grades of the implant complex on resistance under static loading","volume":"8","author":"Park","year":"2016","journal-title":"J\u00a0Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2020.10.022_bib33","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1111\/j.1532-849X.2011.00758.x","article-title":"Effect of implant-abutment connection design on load bearing capacity and failure mode of implants","volume":"20","author":"Dittmer","year":"2011","journal-title":"J\u00a0Prosthodont"},{"key":"10.1016\/j.prosdent.2020.10.022_bib34","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1016\/j.prosdent.2018.10.008","article-title":"Mechanical analysis of a dental implant system under 3 contact conditions and with 2 mechanical factors","volume":"122","author":"Chang","year":"2019","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.10.022_bib35","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1111\/cid.12573","article-title":"Micromotion analysis of different implant configuration, bone density, and crestal cortical bone thickness in immediately loaded mandibular full-arch implant restorations: a nonlinear finite element study","volume":"20","author":"Sugiura","year":"2018","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2020.10.022_bib36","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1515\/amm-2016-0094","article-title":"Tribological characteristic of titanium alloy surface layers produced by diode laser gas nitriding","volume":"61","author":"Lisiecki","year":"2016","journal-title":"Arch Metall Mater"},{"key":"10.1016\/j.prosdent.2020.10.022_bib37","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1002\/jbm.b.30328","article-title":"Influence of implant\/abutment joint designs on abutment screw loosening in a dental implant system","volume":"75","author":"Kitagawa","year":"2005","journal-title":"J\u00a0Biomed Mater Res B Appl Biomater"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391320306934?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391320306934?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T04:05:04Z","timestamp":1778645104000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391320306934"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4]]},"references-count":37,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,4]]}},"alternative-id":["S0022391320306934"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2020.10.022","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2022,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical analysis of the press-fit effect in a conical Morse taper implant system by using an in\u00a0vitro experimental test and finite element analysis","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2020.10.022","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 by the Editorial Council for the Journal of Prosthetic Dentistry.","name":"copyright","label":"Copyright"}]}}