{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T18:31:05Z","timestamp":1780511465140,"version":"3.54.1"},"reference-count":31,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2021,3]]},"DOI":"10.1016\/j.prosdent.2020.11.007","type":"journal-article","created":{"date-parts":[[2021,1,15]],"date-time":"2021-01-15T09:55:57Z","timestamp":1610704557000},"page":"543.e1-543.e10","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"title":["Comparison of CAD-CAM and traditional chairside processing of 4-unit interim prostheses with and without cantilevers: Mechanics, fracture behavior, and finite element analysis"],"prefix":"10.1016","volume":"125","author":[{"given":"Carolina","family":"Coelho","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Catarina","family":"Calamote","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ant\u00f3nio Correia","family":"Pinto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 L.","family":"Esteves","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ant\u00f3nio","family":"Ramos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom\u00e1s","family":"Escuin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7999-4009","authenticated-orcid":false,"given":"J\u00falio C.M.","family":"Souza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2020.11.007_bib1","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1016\/j.dental.2010.11.012","article-title":"Fracture strength of temporary fixed partial dentures: CAD\/CAM versus directly fabricated restorations","volume":"27","author":"Alt","year":"2011","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2020.11.007_bib2","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1016\/j.prosdent.2014.01.012","article-title":"Comparison of the flexural strength and marginal accuracy of traditional and CAD\/CAM interim materials before and after thermal cycling","volume":"112","author":"Yao","year":"2014","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.11.007_bib3","doi-asserted-by":"crossref","first-page":"27","DOI":"10.4047\/jap.2015.7.1.27","article-title":"In\u00a0vitro study of fracture strength of provisional crown materials","volume":"7","author":"Karaokutan","year":"2015","journal-title":"J\u00a0Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2020.11.007_bib4","first-page":"274","article-title":"Potential of innovative digital technologies and CAD\/CAM composites in complex cases with change in the VDO","volume":"12","author":"Guth","year":"2017","journal-title":"Int J Esthet Dent"},{"key":"10.1016\/j.prosdent.2020.11.007_bib5","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1007\/s00784-015-1475-7","article-title":"First clinical experiences with CAD\/CAM-fabricated PMMA-based fixed dental prostheses as long-term temporaries","volume":"20","author":"Huettig","year":"2016","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2020.11.007_bib6","doi-asserted-by":"crossref","first-page":"1669","DOI":"10.1007\/s00784-011-0670-4","article-title":"Load-bearing capacity of CAD\/CAM milled polymeric three-unit fixed dental prostheses: effect of aging regimens","volume":"16","author":"Stawarczyk","year":"2012","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2020.11.007_bib7","first-page":"457","article-title":"CAD\/CAM-generated high-density polymer restorations for the pretreatment of complex cases: a case report","volume":"43","author":"Edelhoff","year":"2012","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2020.11.007_bib8","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.prosdent.2015.03.007","article-title":"Comparison of interim restorations fabricated by CAD\/CAM with those fabricated manually","volume":"114","author":"Rayyan","year":"2015","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.11.007_bib9","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/S0022-3913(13)60378-9","article-title":"Fracture load of milled polymeric fixed dental prostheses as a function of connector cross-sectional areas","volume":"110","author":"Wimmer","year":"2013","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.11.007_bib10","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1038\/sj.bdj.2008.350","article-title":"Digital dentistry: an overview of recent developments for CAD\/CAM generated restorations","volume":"204","author":"Beuer","year":"2008","journal-title":"Br Dent J"},{"key":"10.1016\/j.prosdent.2020.11.007_bib11","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.3109\/00016357.2012.757354","article-title":"Adhesion of veneering resins to polymethylmethacrylate-based CAD\/CAM polymers after various surface conditioning methods","volume":"71","author":"Stawarczyk","year":"2013","journal-title":"Acta Odontol Scand"},{"key":"10.1016\/j.prosdent.2020.11.007_bib12","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.dental.2011.12.003","article-title":"Resin composite blocks via high-pressure high-temperature polymerization","volume":"28","author":"Nguyen","year":"2012","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2020.11.007_bib13","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1111\/j.1365-2842.2008.01855.x","article-title":"Load-bearing capacity of direct four unit provisional composite bridges with fibre reinforcement","volume":"35","author":"Eisenburger","year":"2008","journal-title":"J\u00a0Oral Rehabil"},{"key":"10.1016\/j.prosdent.2020.11.007_bib14","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.1016\/j.dental.2009.05.007","article-title":"Thickness of CAD-CAM composite resin overlays influences fatigue resistance of endodontically treated premolars","volume":"25","author":"Magne","year":"2009","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2020.11.007_bib15","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.prosdent.2018.05.003","article-title":"Energy dissipation capacities of CAD-CAM restorative materials: a comparative evaluation of resilience and toughness","volume":"121","author":"Niem","year":"2019","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.11.007_bib16","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1016\/j.jdent.2012.08.012","article-title":"Fibre reinforcement of two temporary composite bridge materials - effect upon flexural properties","volume":"40","author":"Al Twal","year":"2012","journal-title":"J\u00a0Dent"},{"key":"10.1016\/j.prosdent.2020.11.007_bib17","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1016\/j.dental.2014.01.006","article-title":"Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization - a laboratory study","volume":"30","author":"Keul","year":"2014","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2020.11.007_bib18","first-page":"177","article-title":"Medial mandibular flexure and maximum occlusal force in dentate adults","volume":"19","author":"Canabarro","year":"2006","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2020.11.007_bib19","doi-asserted-by":"crossref","first-page":"49195","DOI":"10.1111\/jopr.12755","article-title":"Comparison of flexural strength of different CAD\/CAM PMMA-based polymers","volume":"28","author":"Alp","year":"2019","journal-title":"J\u00a0Prosthodont"},{"key":"10.1016\/j.prosdent.2020.11.007_bib20","first-page":"161","article-title":"Fiber-reinforced composite fixed dental prostheses with various pontics","volume":"16","author":"Perea","year":"2014","journal-title":"J\u00a0Adhes Dent"},{"key":"10.1016\/j.prosdent.2020.11.007_bib21","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1590\/S1678-77572008000200006","article-title":"Influence of different cantilever extensions and glass or polyaramid reinforcement fibers on fracture strength of implant-supported temporary fixed prosthesis","volume":"16","author":"Col\u00e1n Guzm\u00e1n","year":"2008","journal-title":"J\u00a0Appl Oral Sci"},{"key":"10.1016\/j.prosdent.2020.11.007_bib22","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.prosdent.2014.12.023","article-title":"Comparative study of interim materials for direct fixed dental prostheses and their fabrication with CAD\/CAM technique","volume":"114","author":"Pe\u00f1ate","year":"2015","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2020.11.007_bib23","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.jmbbm.2017.01.013","article-title":"Reinforcement of a PMMA resin for interim fixed prostheses with silica nanoparticles","volume":"69","author":"Topouzi","year":"2017","journal-title":"J\u00a0Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2020.11.007_bib24","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1590\/0103-6440201601418","article-title":"Characterization of bis-acryl composite resins for provisional restorations","volume":"28","author":"Schwantz","year":"2017","journal-title":"Braz Dent J"},{"key":"10.1016\/j.prosdent.2020.11.007_bib25","first-page":"1163","article-title":"Stress distribution of complete-arch implant-supported prostheses reinforced with silica-nylon mesh","volume":"11","author":"Paes-Junior","year":"2019","journal-title":"J\u00a0Clin Exp Dent"},{"key":"10.1016\/j.prosdent.2020.11.007_bib26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2017\/1029574","article-title":"FEM and von Mises analysis on prosthetic crowns structural elements: evaluation of different applied materials","volume":"2017","author":"Bramanti","year":"2017","journal-title":"Sci World J"},{"key":"10.1016\/j.prosdent.2020.11.007_bib27","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.jdent.2017.08.017","article-title":"Influence of specimens' geometry and materials on the thermal stresses in dental restorative materials during thermal cycling","volume":"69","author":"Fabris","year":"2018","journal-title":"J\u00a0Dent"},{"key":"10.1016\/j.prosdent.2020.11.007_bib28","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1080\/10255842.2018.1507025","article-title":"Finite element analysis of peri-implant bone volume affected by stresses around Morse taper implants: effects of implant positioning to the bone crest","volume":"21","author":"Macedo","year":"2018","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"10.1016\/j.prosdent.2020.11.007_bib29","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.jmbbm.2017.03.011","article-title":"Finite\u00a0element analysis of stress extent at peri-implant bone surrounding external hexagon or Morse taper implants","volume":"71","author":"Macedo","year":"2017","journal-title":"J\u00a0Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2020.11.007_bib30","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1016\/j.ijom.2018.02.005","article-title":"Biomechanical simulation of temporomandibular joint replacement (TMJR) devices: a scoping review on the finite element methods","volume":"47","author":"Rodrigues","year":"2018","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.prosdent.2020.11.007_bib31","first-page":"1","article-title":"Enhancing the bone healing on electrical stimuli through the dental implant","volume":"27","author":"Bins-Ely","year":"2020","journal-title":"Comput Methods Biomech Biomed Engin"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391320307034?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391320307034?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T10:56:11Z","timestamp":1758365771000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391320307034"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3]]},"references-count":31,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["S0022391320307034"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2020.11.007","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2021,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of CAD-CAM and traditional chairside processing of 4-unit interim prostheses with and without cantilevers: Mechanics, fracture behavior, and finite element analysis","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2020.11.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 by the Editorial Council for the Journal of Prosthetic Dentistry.","name":"copyright","label":"Copyright"}]}}