{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T03:43:12Z","timestamp":1790394192700,"version":"4.1.0"},"reference-count":34,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100004748","name":"Mashhad University of Medical Sciences","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004748","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["prosdent.org","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2024,5]]},"DOI":"10.1016\/j.prosdent.2022.02.024","type":"journal-article","created":{"date-parts":[[2022,5,4]],"date-time":"2022-05-04T21:16:45Z","timestamp":1651699005000},"page":"865-870","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["A randomized clinical trial comparing the clinical fit and chairside adjustment time for implant-supported crowns fabricated by fully digital and partially digital techniques"],"prefix":"10.1016","volume":"131","author":[{"given":"Hamidreza Rajati","family":"Haghi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jalil","family":"Ghanbarzadeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1925-1689","authenticated-orcid":false,"given":"Ehsan","family":"Kiamanesh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2022.02.024_bib1","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1111\/j.1600-0501.2007.01439.x","article-title":"Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs)","volume":"18","author":"Pjetursson","year":"2007","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib2","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1111\/jopr.12014","article-title":"Evidenced-based criteria for differential treatment planning of implant restorations for the partially edentulous patient","volume":"22","author":"Sadowsky","year":"2013","journal-title":"J\u00a0Prosthodont"},{"key":"10.1016\/j.prosdent.2022.02.024_bib3","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1111\/clr.13300","article-title":"Is the use of digital technologies for the fabrication of implant-supported reconstructions more efficient and\/or more effective than conventional techniques: a systematic review","volume":"29","author":"Muhlemann","year":"2018","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib4","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1007\/s00784-017-2217-9","article-title":"Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure","volume":"22","author":"Menini","year":"2018","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2022.02.024_bib5","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/j.prosdent.2016.06.011","article-title":"Marginal fit and photoelastic stress analysis of CAD-CAM and overcast 3-unit implant-supported frameworks","volume":"117","author":"Presotto","year":"2017","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2022.02.024_bib6","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1097\/00008505-200104000-00003","article-title":"The significance of passive framework fit in implant prosthodontics: current status","volume":"10","author":"Sahin","year":"2001","journal-title":"Implant Dent"},{"key":"10.1016\/j.prosdent.2022.02.024_bib7","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.prosdent.2014.07.010","article-title":"Influence of CAD-CAM on the fit accuracy of implant-supported zirconia and cobalt-chromium fixed dental prostheses","volume":"113","author":"de Fran\u00e7a","year":"2015","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2022.02.024_bib8","first-page":"101","article-title":"Accuracy of digital implant impressions with intraoral scanners. a systematic review","volume":"10","author":"Rutk\u016bnas","year":"2017","journal-title":"Eur J Oral Implantol"},{"key":"10.1016\/j.prosdent.2022.02.024_bib9","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/S0022-3913(08)60208-5","article-title":"The accuracy of implant impressions: a systematic review","volume":"100","author":"Lee","year":"2008","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2022.02.024_bib10","first-page":"506","article-title":"Assessing the fit of implant fixed prostheses: a critical review","volume":"25","author":"Abduo","year":"2010","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2022.02.024_bib11","first-page":"121","article-title":"Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature","volume":"10","author":"Katsoulis","year":"2017","journal-title":"Eur J Oral Implantol"},{"key":"10.1016\/j.prosdent.2022.02.024_bib12","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/S0022-3913(08)60215-2","article-title":"Simple technique to transfer occlusal vertical dimension and articulate a definitive implant cast for a full arch implant prosthesis","volume":"100","author":"Papaspyridakos","year":"2008","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2022.02.024_bib13","first-page":"469","article-title":"Clinical accuracy outcomes of closed-tray and open-tray implant impression techniques for partially edentulous patients","volume":"24","author":"Gallucci","year":"2011","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2022.02.024_bib14","doi-asserted-by":"crossref","first-page":"836","DOI":"10.11607\/jomi.3625","article-title":"Accuracy of implant impressions for partially and completely edentulous patients: a systematic review","volume":"29","author":"Papaspyridakos","year":"2014","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2022.02.024_bib15","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1111\/clr.13273","article-title":"The accuracy of different dental impression techniques for implant-supported dental prostheses: a systematic review and meta-analysis","volume":"29","author":"Fl\u00fcgge","year":"2018","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib16","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1111\/jopr.12764","article-title":"A\u00a0clinical comparative study of 3-dimensional accuracy between digital and conventional implant impression techniques","volume":"28","author":"Alsharbaty","year":"2019","journal-title":"J\u00a0Prosthodont"},{"key":"10.1016\/j.prosdent.2022.02.024_bib17","first-page":"30","article-title":"In\u00a0vitro study on passive fit in implant-supported 5-unit fixed partial dentures","volume":"19","author":"Karl","year":"2004","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2022.02.024_bib18","first-page":"110","article-title":"Computer-aided design and computer-assisted manufacturing in prosthetic implant dentistry","volume":"24","author":"Kapos","year":"2009","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2022.02.024_bib19","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/j.prosdent.2015.03.022","article-title":"Digital process for an implant-supported fixed dental prosthesis: a clinical report","volume":"114","author":"Brandt","year":"2015","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2022.02.024_bib20","first-page":"457","article-title":"The Cerec system: computer assisted preparation of direct ceramic inlays in 1 setting","volume":"38","author":"Mormann","year":"1987","journal-title":"Quintessenz"},{"key":"10.1016\/j.prosdent.2022.02.024_bib21","first-page":"185","article-title":"Patient-centered outcomes comparing digital and conventional implant impression procedures: a randomized crossover trial","volume":"2","author":"Joda","year":"2016","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib22","doi-asserted-by":"crossref","first-page":"1430","DOI":"10.1111\/clr.12476","article-title":"Digital vs conventional implant prosthetic workflows: a cost\/time analysis","volume":"26","author":"Joda","year":"2014","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib23","doi-asserted-by":"crossref","first-page":"1401","DOI":"10.1111\/clr.12753","article-title":"Time-efficiency analysis of the treatment with monolithic implant crowns in a digital workflow: a randomized controlled trial","volume":"27","author":"Joda","year":"2016","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib24","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.11607\/jomi.3963","article-title":"Time-efficiency analysis comparing digital and conventional workflows for implant crowns: a prospective clinical crossover trial","volume":"30","author":"Joda","year":"2015","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2022.02.024_bib25","doi-asserted-by":"crossref","first-page":"1304","DOI":"10.1111\/clr.12270","article-title":"Complete digital workflow for the production of implant-supported single-unit monolithic crowns","volume":"25","author":"Joda","year":"2014","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib26","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1111\/cid.12124","article-title":"Accuracy of a digital scan system based on active wavefront sampling technology for implants considering operator experience, implant angulation, and depth","volume":"17","author":"Gim\u00e9nez","year":"2015","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib27","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1111\/clr.12234","article-title":"Patients\u2019 preferences when comparing analogue implant impressions using a polyether impression material versus digital scans of dental implants","volume":"25","author":"Wismeijer","year":"2014","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib28","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1111\/prd.12164","article-title":"Digital technology in fixed implant prosthodontics","volume":"73","author":"Joda","year":"2017","journal-title":"Periodontol 2000"},{"key":"10.1016\/j.prosdent.2022.02.024_bib29","first-page":"165","article-title":"Fatigue fracture strength of implant-supported complete contour zirconia and metal ceramic fixed partial dentures","volume":"14","author":"Vafaee","year":"2017","journal-title":"J\u00a0Dent"},{"key":"10.1016\/j.prosdent.2022.02.024_bib30","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1111\/clr.13447","article-title":"Time efficiency and quality of outcomes in a model-free digital workflow using digital impression immediately after implant placement: a double-blind self-controlled clinical trial","volume":"30","author":"Pan","year":"2019","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib31","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1111\/cid.12472","article-title":"Monolithic implant-supported lithium disilicate (LS2) crowns in a complete digital workflow: a prospective clinical trial with a 2-year follow-up","volume":"19","author":"Joda","year":"2017","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib32","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1111\/clr.12982","article-title":"Time efficiency, difficulty, and operator\u2019s preference comparing digital and conventional implant impressions: a randomized controlled trial","volume":"28","author":"Joda","year":"2017","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2022.02.024_bib33","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.prosdent.2013.07.010","article-title":"Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: a pilot study","volume":"111","author":"Andriessen","year":"2014","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2022.02.024_bib34","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1111\/cid.12377","article-title":"Clinical fitting and adjustment time for implant-supported crowns comparing digital and conventional workflows","volume":"18","author":"Joda","year":"2016","journal-title":"Clin Implant Dent Relat Res"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391322001949?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391322001949?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T14:53:45Z","timestamp":1715266425000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391322001949"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5]]},"references-count":34,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024,5]]}},"alternative-id":["S0022391322001949"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2022.02.024","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2024,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A randomized clinical trial comparing the clinical fit and chairside adjustment time for implant-supported crowns fabricated by fully digital and partially digital techniques","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2022.02.024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 by the Editorial Council for the Journal of Prosthetic Dentistry.","name":"copyright","label":"Copyright"}]}}