{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T13:44:28Z","timestamp":1792590268259,"version":"4.5.0"},"reference-count":36,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,1,30]],"date-time":"2023-01-30T00:00:00Z","timestamp":1675036800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100013302","name":"King Abdullah International Medical Research Center","doi-asserted-by":"publisher","award":["NRC22R\/156\/03"],"award-info":[{"award-number":["NRC22R\/156\/03"]}],"id":[{"id":"10.13039\/501100013302","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2024,6]]},"DOI":"10.1016\/j.prosdent.2023.01.027","type":"journal-article","created":{"date-parts":[[2023,2,24]],"date-time":"2023-02-24T10:39:45Z","timestamp":1677235185000},"page":"1218-1225","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":47,"title":["Impact of intraoral scanner, scanning strategy, and scanned arch on the scan accuracy of edentulous arches: An in\u00a0vitro study"],"prefix":"10.1016","volume":"131","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5416-8322","authenticated-orcid":false,"given":"Faris Z.","family":"Jamjoom","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adhwaa","family":"Aldghim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omar","family":"Aldibasi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Burak","family":"Yilmaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2023.01.027_bib1","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1111\/jopr.12527","article-title":"Digital versus conventional impressions in fixed prosthodontics: a review","volume":"27","author":"Ahlholm","year":"2018","journal-title":"J\u00a0Prosthodont"},{"key":"10.1016\/j.prosdent.2023.01.027_bib2","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.cden.2018.11.006","article-title":"Management of edentulous patients","volume":"63","author":"Lee","year":"2019","journal-title":"Dent Clin North Am"},{"key":"10.1016\/j.prosdent.2023.01.027_bib3","doi-asserted-by":"crossref","first-page":"377","DOI":"10.11607\/ijp.5741","article-title":"Using intraoral scanning to capture complete denture impressions, tooth positions, and centric relation records","volume":"31","author":"Goodacre","year":"2018","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2023.01.027_bib4","first-page":"488","article-title":"Evaluation of the accuracy of multiple digital impression systems on a fully edentulous maxilla","volume":"52","author":"Gutmacher","year":"2021","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2023.01.027_bib5","doi-asserted-by":"crossref","first-page":"761.e1","DOI":"10.1016\/j.prosdent.2020.07.018","article-title":"Accuracy of a chairside intraoral scanner compared with a laboratory scanner for the completely edentulous maxilla: an in\u00a0vitro 3-dimensional comparative analysis","volume":"124","author":"Zarone","year":"2020","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib6","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/j.prosdent.2019.04.004","article-title":"Three-dimensional differences between intraoral scans and conventional impressions of edentulous jaws: a clinical study","volume":"123","author":"Lo Russo","year":"2020","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib7","first-page":"265","article-title":"Accuracy of intraoral scanning of edentulous jaws with and without resin markers","volume":"23","author":"Tao","year":"2020","journal-title":"Chin J Dent Res"},{"key":"10.1016\/j.prosdent.2023.01.027_bib8","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1002\/1097-4636(2001)58:3<217::AID-JBM1010>3.0.CO;2-V","article-title":"Dimensional changes of dental impression materials by thermal changes","volume":"58","author":"Kim","year":"2001","journal-title":"J\u00a0Biomed Mater Res"},{"key":"10.1016\/j.prosdent.2023.01.027_bib9","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.prosdent.2017.09.004","article-title":"Single-arch digital removable complete denture: a workflow that starts from the intraoral scan","volume":"120","author":"Lo Russo","year":"2018","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib10","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1111\/jopr.13345","article-title":"Accuracy of intraoral scanners for recording the denture bearing areas: a systematic review","volume":"30","author":"Rasaie","year":"2021","journal-title":"J\u00a0Prosthodont"},{"key":"10.1016\/j.prosdent.2023.01.027_bib11","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1016\/j.prosdent.2018.08.016","article-title":"Edentulous jaw impression techniques: an in\u00a0vivo comparison of trueness","volume":"121","author":"Chebib","year":"2019","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib12","doi-asserted-by":"crossref","first-page":"1839","DOI":"10.1007\/s00784-020-03486-z","article-title":"Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in\u00a0vitro analysis","volume":"25","author":"Schimmel","year":"2021","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2023.01.027_bib13","doi-asserted-by":"crossref","first-page":"914","DOI":"10.14219\/jada.archive.2013.0209","article-title":"Assessing the feasibility and accuracy\u00a0of digitizing edentulous jaws","volume":"144","author":"Patzelt","year":"2013","journal-title":"J\u00a0Am Dent Assoc"},{"key":"10.1016\/j.prosdent.2023.01.027_bib14","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.jpor.2019.12.003","article-title":"Computerized optical impression making of edentulous jaws - An in\u00a0vivo feasibility study","volume":"64","author":"Hack","year":"2020","journal-title":"J\u00a0Prosthodont Res"},{"key":"10.1016\/j.prosdent.2023.01.027_bib15","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1186\/s12903-019-0918-y","article-title":"Applying intraoral scanner to residual ridge in edentulous regions: in\u00a0vitro evaluation of inter-operator validity to confirm trueness","volume":"19","author":"Tasaka","year":"2019","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.prosdent.2023.01.027_bib16","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.jpor.2019.05.005","article-title":"Full arch precision of six intraoral scanners in\u00a0vitro","volume":"64","author":"Osnes","year":"2020","journal-title":"J\u00a0Prosthodont Res"},{"key":"10.1016\/j.prosdent.2023.01.027_bib17","doi-asserted-by":"crossref","first-page":"179","DOI":"10.4047\/jap.2019.11.3.179","article-title":"Comparison of different impression techniques for edentulous jaws using three-dimensional analysis","volume":"11","author":"Jung","year":"2019","journal-title":"J\u00a0Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2023.01.027_bib18","doi-asserted-by":"crossref","first-page":"762.e1","DOI":"10.1016\/j.prosdent.2020.07.017","article-title":"Comparison of different intraoral scanning techniques on the completely edentulous maxilla: an in\u00a0vitro 3-dimensional comparative analysis","volume":"124","author":"Zarone","year":"2020","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib19","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.prosdent.2020.09.038","article-title":"Accuracy of impression-making\u00a0methods in edentulous arches: An in\u00a0vitro study encompassing conventional and digital methods","volume":"128","author":"Li","year":"2022","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib20","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1111\/cid.12821","article-title":"The effect of scanning the palate and scan body position on the accuracy of complete-arch implant scans","volume":"21","author":"Mizumoto","year":"2019","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2023.01.027_bib21","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1016\/j.prosdent.2017.05.008","article-title":"Digital intraoral scanning technique for edentulous jaws","volume":"119","author":"Fang","year":"2018","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib22","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1186\/s12903-019-0751-3","article-title":"Deviations in palatal region between indirect and direct digital models: an in\u00a0vivo study","volume":"19","author":"Zhongpeng","year":"2019","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.prosdent.2023.01.027_bib23","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s12903-019-0733-5","article-title":"Intraoral scanning to fabricate complete dentures with functional borders: a proof-of-concept case report","volume":"19","author":"Unkovskiy","year":"2019","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.prosdent.2023.01.027_bib24","doi-asserted-by":"crossref","first-page":"166","DOI":"10.11607\/ijp.5624","article-title":"Using intraoral scanning to fabricate complete dentures: first experiences","volume":"31","author":"Goodacre","year":"2018","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2023.01.027_bib25","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.jpor.2017.05.005","article-title":"Development of complete dentures based on digital intraoral impressions-Case report","volume":"62","author":"Fang","year":"2018","journal-title":"J\u00a0Prosthodont Res"},{"key":"10.1016\/j.prosdent.2023.01.027_bib26","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1016\/j.prosdent.2022.07.004","article-title":"Fit and retention of complete denture bases: Part II - conventional impressions versus digital scans: a clinical controlled crossover study","volume":"131","author":"Chebib","year":"2024","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib27","article-title":"Comparative evaluation of digitally fabricated complete dentures versus conventional complete dentures: a randomized, single-blinded, cross-over clinical trial","author":"Kang","year":"2022","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib29","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1111\/jopr.13158","article-title":"Effects of scanning strategy and scanner type on the accuracy of intraoral scans: a new approach for assessing the accuracy of scanned data","volume":"29","author":"Oh","year":"2020","journal-title":"J\u00a0Prosthodont"},{"key":"10.1016\/j.prosdent.2023.01.027_bib30","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1111\/jopr.13211","article-title":"Digital vs conventional implant impressions: A systematic review and meta-analysis","volume":"29","author":"Papaspyridakos","year":"2020","journal-title":"J\u00a0Prosthodont"},{"key":"10.1016\/j.prosdent.2023.01.027_bib31","article-title":"Accuracy of four digital scanners according to scanning strategy in complete-arch impressions","volume":"13","author":"Medina-Sotomayor","year":"2018","journal-title":"PLoS One"},{"key":"10.1016\/j.prosdent.2023.01.027_bib32","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.prosdent.2019.02.008","article-title":"Effect of scan pattern on complete-arch scans with 4 digital scanners","volume":"123","author":"Latham","year":"2020","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib33","doi-asserted-by":"crossref","first-page":"123","DOI":"10.3390\/dj10070123","article-title":"The effect of scanning strategy on intraoral scanner's accuracy","volume":"10","author":"Gavounelis","year":"2022","journal-title":"Dent J (Basel)"},{"key":"10.1016\/j.prosdent.2023.01.027_bib34","first-page":"307","article-title":"Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in\u00a0vitro study","volume":"22","author":"Passos","year":"2019","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib35","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.prosdent.2021.05.021","article-title":"Feasibility of using an intraoral scanner for a complete-arch digital scan, part 2: a comparison of scan strategies","volume":"129","author":"Son","year":"2023","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib38","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.prosdent.2016.08.019","article-title":"Improved digital impressions of edentulous areas","volume":"117","author":"Lee","year":"2017","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.01.027_bib39","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1111\/j.1532-849X.1999.tb00022.x","article-title":"A\u00a0technique for border molding edentulous impressions using vinyl polysiloxane material","volume":"8","author":"Chaffee","year":"1999","journal-title":"J\u00a0Prosthodont"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391323000690?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391323000690?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T20:38:32Z","timestamp":1778704712000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391323000690"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6]]},"references-count":36,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["S0022391323000690"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2023.01.027","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2024,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Impact of intraoral scanner, scanning strategy, and scanned arch on the scan accuracy of edentulous arches: An in\u00a0vitro study","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2023.01.027","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Inc. on behalf of the Editorial Council for the Journal of Prosthetic Dentistry.","name":"copyright","label":"Copyright"}]}}