{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T07:08:51Z","timestamp":1781680131178,"version":"3.54.5"},"reference-count":35,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2024,2]]},"DOI":"10.1016\/j.prosdent.2023.07.015","type":"journal-article","created":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T07:49:14Z","timestamp":1692690554000},"page":"273-280","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Marginal fit and fracture resistance of polyetheretherketone, zirconia, and titanium implant-supported prosthesis frameworks for a partially edentulous arch after thermomechanical aging"],"prefix":"10.1016","volume":"131","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7011-3375","authenticated-orcid":false,"given":"Saadet","family":"Atsu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulas","family":"Erol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2023.07.015_bib1","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1111\/j.1708-8208.2011.00395.x","article-title":"\u201cAll-on-4\u2033 immediate-function concept for completely edentulous maxillae: A clinical report on the medium (3 years) and long-term (5 years) outcomes","volume":"14","author":"Mal\u00f3","year":"2012","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2023.07.015_bib2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.joms.2018.05.024","article-title":"Implant-supported hybrid prosthesis for severe mandibular defects: A sequence of treatments from alveolar distraction osteogenesis to implant restoration","volume":"76","author":"Zhuang","year":"2018","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.prosdent.2023.07.015_bib3","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1111\/scd.12345","article-title":"Multidisciplinary rehabilitation of eosinophilic granuloma with bone graft surgery and a modified implant-supported hybrid prosthesis: A case report with a 6-year follow-up","volume":"39","author":"Kurt","year":"2019","journal-title":"Spec Care Dentist"},{"key":"10.1016\/j.prosdent.2023.07.015_bib4","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.3390\/jcm9072187","article-title":"Hybrid polyetheretherketone (peek)\u2013acrylic resin prostheses and the all-on-4 concept: A full-arch implant-supported fixed solution with 3 years of follow-up","volume":"10","author":"de Ara\u00fajo Nobre","year":"2020","journal-title":"J Clin Med"},{"key":"10.1016\/j.prosdent.2023.07.015_bib5","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1111\/cid.12662","article-title":"Short-term report of an ongoing prospective cohort study evaluating the outcome of full-arch implant-supported fixed hybrid polyetheretherketone-acrylic resin prostheses and the All-on-Four concept","volume":"20","author":"Mal\u00f3","year":"2018","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2023.07.015_bib6","series-title":"Contemporary Fixed Prosthodontics","first-page":"384","author":"Rosenstiel","year":"2022"},{"key":"10.1016\/j.prosdent.2023.07.015_bib7","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.prosdent.2017.04.023","article-title":"In vitro fit of CAD-CAM complete arch screw-retained Ti and Zr implant prostheses fabricated on 4 implants","volume":"119","author":"Al-Meraikhi","year":"2018","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib8","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.prosdent.2017.11.021","article-title":"Marginal discrepancy of CAD-CAM complete arch-fixed implant-supported frameworks","volume":"120","author":"Yilmaz","year":"2018","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib9","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1016\/j.prosdent.2020.03.018","article-title":"Discrepancy at the implant abutment-prosthesis interface of complete-arch cobalt-chromium implant frameworks fabricated by additive and subtractive technologies before and after ceramic veneering","volume":"125","author":"Revilla-Le\u00f3n","year":"2021","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib10","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1111\/clr.12522","article-title":"CAD\/CAM fabrication accuracy of long- vs. short-span implant-supported FDP","volume":"26","author":"Katsoulis","year":"2015","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2023.07.015_bib11","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103784","article-title":"Trueness and marginal fit of implant-supported complete-arch fixed prosthesis frameworks made of high-performance polymers and Ti: An explorative in-vitro study","volume":"113","author":"Abou-Ayash","year":"2021","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib12","first-page":"270","article-title":"Failures and complications in 391 consecutively inserted fixed prostheses supported by Br\u00e5nemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup","volume":"6","author":"Jemt","year":"1991","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2023.07.015_bib13","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1111\/jopr.13022","article-title":"Evaluation of the marginal and internal fit of implant-supported metal copings fabricated with 3 different techniques: An in vitro study","volume":"28","author":"Yildirim","year":"2019","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2023.07.015_bib14","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1111\/j.1708-8208.2010.00334.x","article-title":"A comparison of fit of CNC-milled Ti and Zr frameworks to implants","volume":"14","author":"Abduo","year":"2012","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2023.07.015_bib15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.prosdent.2020.03.014","article-title":"Effect of porcelain firing and cementation on the marginal fit of implant-supported metal-ceramic restorations fabricated by additive or subtractive manufacturing methods","volume":"124","author":"Yildirim","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib16","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.prosdent.2021.06.022","article-title":"An assessment of the passivity of the fit of multiunit screw-retained implant frameworks manufactured by using additive and subtractive technologies","volume":"129","author":"Abu Ghofa","year":"2023","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.prosdent.2020.12.001","article-title":"Influence of luting space of zirconia abutment on marginal discrepancy and tensile strength after dynamic loading","volume":"125","author":"Pacheco","year":"2021","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib18","article-title":"Effect of adhesive system, resin cement, heat-pressing technique, and thermomechanical aging on the adhesion between titanium base and a high-performance polymer","volume":"2","author":"Yilmaz","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib19","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1016\/j.prosdent.2020.06.013","article-title":"Effect of airborne-particle abrasion of a titanium base abutment on the stability of the bonded interface and retention forces of crowns after artificial aging","volume":"126","author":"Pitta","year":"2021","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib20","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/j.dental.2021.03.015","article-title":"Mechanical behavior of nano-hybrid composite in comparison to lithium disilicate as posterior cement-retained implant-supported crowns restoring different abutments","volume":"37","author":"Elsayed","year":"2021","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2023.07.015_bib21","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1111\/j.1600-0501.2011.02311.x","article-title":"Damping behavior of implant-supported restorations","volume":"24","author":"Magne","year":"2013","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2023.07.015_bib22","doi-asserted-by":"crossref","first-page":"116","DOI":"10.11607\/jomi.5463","article-title":"In vitro shock absorption tests on implant-supported crowns: influence of crown materials and luting agents","volume":"33","author":"Rosentritt","year":"2018","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2023.07.015_bib23","doi-asserted-by":"crossref","first-page":"1372","DOI":"10.1902\/jop.2001.72.10.1372","article-title":"Influence of the size of the microgap on crestal bone changes around Ti implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible","volume":"72","author":"Hermann","year":"2001","journal-title":"J Periodontol"},{"key":"10.1016\/j.prosdent.2023.07.015_bib24","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1046\/j.1365-2842.2001.00692.x","article-title":"Quantitative study of bite force during sleep associated bruxism","volume":"28","author":"Nishigawa","year":"2001","journal-title":"J Oral Rehabil"},{"key":"10.1016\/j.prosdent.2023.07.015_bib25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.prosdent.2021.04.023","article-title":"The effect of nanocoatings of SiO2, TiO2, and ZrO2 on Ti-porcelain bonding","volume":"126","author":"Atsu","year":"2021","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib26","doi-asserted-by":"crossref","first-page":"622","DOI":"10.11607\/jomi.7036","article-title":"Fracture resistance of Ti, Zr, and ceramic-reinforced polyetheretherketone implant abutments supporting CAD\/CAM monolithic lithium disilicate ceramic crowns after aging","volume":"34","author":"Ats\u00fc","year":"2019","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2023.07.015_bib27","first-page":"400","article-title":"Fracture strength of three-unit implant supported fixed partial dentures with excessive crown height fabricated from different materials","volume":"13","author":"Nazari","year":"2016","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib28","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.prosdent.2015.06.022","article-title":"Flexural strength of small connector designs of Zr-based partial fixed dental prostheses","volume":"115","author":"Hamza","year":"2016","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib29","first-page":"231","article-title":"Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: A laboratory study","volume":"14","author":"Tinschert","year":"2001","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2023.07.015_bib30","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.3390\/ma15031016","article-title":"Prosthetic materials used for implant-supported restorations and their biochemical oral interactions: A narrative review","volume":"15","author":"Ionescu","year":"2022","journal-title":"Materials"},{"key":"10.1016\/j.prosdent.2023.07.015_bib31","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1111\/jopr.13173","article-title":"Static and fatigue loading of veneered implant-supported fixed dental prostheses","volume":"29","author":"Rayyan","year":"2020","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2023.07.015_bib32","doi-asserted-by":"crossref","first-page":"488","DOI":"10.11607\/jomi.2772","article-title":"In vitro fatigue and fracture strength testing of one-piece Zr \u0131mplant abutments and Zr \u0131mplant abutments connected to Ti cores","volume":"28","author":"Stimmelmayr","year":"2013","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2023.07.015_bib33","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1111\/j.2041-1626.2012.00149.x","article-title":"Stress dissipation in the bone through various crown materials of dental implant restoration: A 2-D finite element analysis","volume":"4","author":"Bijjargi","year":"2013","journal-title":"J Investig Clin Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib34","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.prosdent.2019.03.003","article-title":"Comparative evaluation of BioHPP and Ti as a framework veneered with composite resin for implant-supported fixed dental prostheses","volume":"122","author":"Jin","year":"2019","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.07.015_bib35","doi-asserted-by":"crossref","first-page":"35","DOI":"10.3390\/dj5040035","article-title":"PEEK with reinforced materials and modifications for dental implant applications","volume":"15","author":"Rahmitasari","year":"2017","journal-title":"Dent J"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391323004870?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391323004870?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T11:02:50Z","timestamp":1758366170000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391323004870"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2]]},"references-count":35,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["S0022391323004870"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2023.07.015","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Marginal fit and fracture resistance of polyetheretherketone, zirconia, and titanium implant-supported prosthesis frameworks for a partially edentulous arch after thermomechanical aging","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2023.07.015","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2024 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights reserved.","name":"copyright","label":"Copyright"}]}}