{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T23:05:54Z","timestamp":1775689554850,"version":"3.50.1"},"reference-count":30,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100004663","name":"Ministry of Science and Technology, Taiwan","doi-asserted-by":"publisher","award":["109-2314-B-038-028"],"award-info":[{"award-number":["109-2314-B-038-028"]}],"id":[{"id":"10.13039\/501100004663","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100020595","name":"Ministry of Science and Technology","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100020595","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2024,2]]},"DOI":"10.1016\/j.prosdent.2023.09.042","type":"journal-article","created":{"date-parts":[[2023,12,5]],"date-time":"2023-12-05T18:46:52Z","timestamp":1701802012000},"page":"291.e1-291.e9","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Comparative analysis of the retention force and deformation of PEEK and PEKK removable partial denture clasps with different thicknesses and undercut depths"],"prefix":"10.1016","volume":"131","author":[{"given":"Wei-Fang","family":"Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"May-Show","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7168-9429","authenticated-orcid":false,"given":"Tzu-Yu","family":"Peng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peng-Chien","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Nikawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3575-4174","authenticated-orcid":false,"given":"Pei-Wen","family":"Peng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2023.09.042_bib1","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.prosdent.2017.01.008","article-title":"Removable partial dentures: The clinical need for innovation","volume":"118","author":"Campbell","year":"2017","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.09.042_bib2","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1038\/sj.bdj.4800854a","article-title":"Retention","volume":"189","author":"Davenport","year":"2000","journal-title":"Br Dent J"},{"key":"10.1016\/j.prosdent.2023.09.042_bib3","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/j.jpor.2019.02.005","article-title":"Change in the retentive force of Akers clasp for zirconia crown by repetitive insertion and removal test","volume":"63","author":"Tanaka","year":"2019","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2023.09.042_bib4","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/S0022-3913(10)60173-4","article-title":"Cyclic fatigue properties of cobalt-chromium alloy clasps for partial removable dental prostheses","volume":"104","author":"Cheng","year":"2010","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.09.042_bib5","first-page":"ZC37","article-title":"An evaluation of retentive ability and deformation of acetal resin and cobalt-chromium clasps","volume":"10","author":"Meenakshi","year":"2016","journal-title":"J Clin Diagnostic Res"},{"key":"10.1016\/j.prosdent.2023.09.042_bib6","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1067\/mpr.2002.128128","article-title":"Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures","volume":"88","author":"Rodrigues","year":"2002","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.09.042_bib7","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.jpor.2013.01.006","article-title":"Fatigue resistance and retentive force of cast clasps treated by shot peening","volume":"57","author":"Tokue","year":"2013","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2023.09.042_bib8","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.prosdent.2005.06.009","article-title":"An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps","volume":"94","author":"Arda","year":"2005","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.09.042_bib9","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/S0022-3913(99)70054-5","article-title":"Clinical methods for adjusting retention force of cast clasps","volume":"82","author":"Sato","year":"1999","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.09.042_bib10","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/0022-3913(81)90386-3","article-title":"A study of the flexibility of wrought wire clasps","volume":"45","author":"Frank","year":"1981","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.09.042_bib11","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/j.prosdent.2019.10.020","article-title":"A speech bulb prosthesis for a soft palate defect with a polyetherketoneketone (PEKK) framework fabricated by multiple digital techniques: A clinical report","volume":"124","author":"Sun","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.09.042_bib12","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1016\/j.prosdent.2015.03.002","article-title":"Cobalt-chromium alloys in dentistry: An evaluation of metal ion release","volume":"114","author":"Lucchetti","year":"2015","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.09.042_bib13","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1111\/jopr.13398","article-title":"Retentive forces of removable partial denture clasp assemblies made from polyaryletherketone and cobalt-chromium: A comparative study","volume":"31","author":"Gentz","year":"2022","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2023.09.042_bib14","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.prosdent.2018.12.007","article-title":"The effect of build orientation on the microstructure and properties of selective laser melting Ti-6Al-4V for removable partial denture clasps","volume":"123","author":"Xie","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.09.042_bib15","doi-asserted-by":"crossref","first-page":"e595","DOI":"10.1111\/jopr.12968","article-title":"CAD\/CAM constructed poly (etheretherketone) (PEEK) framework of Kennedy class I removable partial denture: A clinical report","volume":"28","author":"J Harb","year":"2019","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2023.09.042_bib16","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.prosdent.2020.06.035","article-title":"Trueness of removable partial denture frameworks additively manufactured with selective laser melting","volume":"127","author":"Peng","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2023.09.042_bib17","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.jpor.2018.01.001","article-title":"Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling","volume":"62","author":"Torii","year":"2018","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2023.09.042_bib18","doi-asserted-by":"crossref","first-page":"304","DOI":"10.4047\/jap.2021.13.5.304","article-title":"The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut","volume":"13","author":"G\u00fclery\u00fcz","year":"2021","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2023.09.042_bib19","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.dental.2011.10.016","article-title":"Retentive forces and fatigue resistance of thermoplastic resin clasps","volume":"28","author":"Tannous","year":"2012","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2023.09.042_bib20","doi-asserted-by":"crossref","first-page":"e113","DOI":"10.1016\/j.dental.2019.02.028","article-title":"Deformation and retentive force following in vitro cyclic fatigue of cobalt-chrome and aryl ketone polymer (AKP) clasps","volume":"35","author":"Marie","year":"2019","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2023.09.042_bib21","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.jpor.2019.01.002","article-title":"Influence of block-out on retentive force of thermoplastic resin clasps: An in vitro experimental and finite element analysis","volume":"63","author":"Yamazaki","year":"2019","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2023.09.042_bib22","first-page":"87","article-title":"Polyetherketoneketone (PEKK): An emerging biomaterial for oral implants and dental prostheses","volume":"28","author":"Alqurashi","year":"2021","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2023.09.042_bib23","first-page":"19","article-title":"A review of PEEK polymer\u2019s properties and its use in prosthodontics","volume":"19","author":"Skirbutis","year":"2017","journal-title":"Stomatologija"},{"key":"10.1016\/j.prosdent.2023.09.042_bib24","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1016\/j.dental.2015.08.151","article-title":"Flexural behavior of PEEK materials for dental application","volume":"31","author":"Schwitalla","year":"2015","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2023.09.042_bib25","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.jpor.2019.07.012","article-title":"Finite-element analysis and optimization of the mechanical properties of polyetheretherketone (PEEK) clasps for removable partial dentures","volume":"64","author":"Peng","year":"2020","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2023.09.042_bib26","first-page":"124","article-title":"Strength and flexibility of lithium disilicate bonded to polyetherketoneketone","volume":"130","author":"Ruse","year":"2023","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2023.09.042_bib27","doi-asserted-by":"crossref","first-page":"13975","DOI":"10.1038\/s41598-019-50363-1","article-title":"A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK","volume":"9","author":"Chen","year":"2019","journal-title":"Sci Rep"},{"key":"10.1016\/j.prosdent.2023.09.042_bib28","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1111\/joor.12035","article-title":"Long-term tooth loss in periodontally compromised but treated patients according to the type of prosthodontic treatment. A retrospective study","volume":"40","author":"M\u00fcller","year":"2013","journal-title":"J Oral Rehabil"},{"key":"10.1016\/j.prosdent.2023.09.042_bib29","doi-asserted-by":"crossref","first-page":"386","DOI":"10.11607\/ijp.6604","article-title":"A pilot randomized controlled crossover trial comparing early OHRQoL outcomes of cobalt-chromium versus PEEK removable partial denture frameworks","volume":"33","author":"Ali","year":"2020","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2023.09.042_bib30","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.jpor.2014.03.002","article-title":"Clinical application of removable partial dentures using thermoplastic resin. Part II: Material properties and clinical features of non-metal clasp dentures","volume":"58","author":"Fueki","year":"2014","journal-title":"J Prosthodont Res"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391323007138?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391323007138?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T11:04:05Z","timestamp":1758366245000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391323007138"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["S0022391323007138"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2023.09.042","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparative analysis of the retention force and deformation of PEEK and PEKK removable partial denture clasps with different thicknesses and undercut depths","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2023.09.042","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2024 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights reserved.","name":"copyright","label":"Copyright"}]}}