{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T13:55:38Z","timestamp":1784642138786,"version":"3.55.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100004386","name":"Universiti Malaya","doi-asserted-by":"publisher","award":["DPRG\/16\/21"],"award-info":[{"award-number":["DPRG\/16\/21"]}],"id":[{"id":"10.13039\/501100004386","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2025,11]]},"DOI":"10.1016\/j.prosdent.2024.03.020","type":"journal-article","created":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T16:06:39Z","timestamp":1713197199000},"page":"1836-1842","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Adaptation of cobalt chromium frameworks fabricated by conventional versus selective laser melting techniques: An in vitro and clinical assessment"],"prefix":"10.1016","volume":"134","author":[{"given":"Safa Salim","family":"Elhadery","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed Nasser","family":"Alhajj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norsiah","family":"Yunus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norliza","family":"Ibrahim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zubaidah Zanul","family":"Abidin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5268-9231","authenticated-orcid":false,"given":"Siti Fauzza","family":"Ahmad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nosizana Mohd","family":"Salleh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2024.03.020_bib1","doi-asserted-by":"crossref","first-page":"974","DOI":"10.5272\/jimab.2015214.974","article-title":"Modern trends in the development of the technologies for production of dental constructions","volume":"21","author":"Dikova","year":"2015","journal-title":"J IMAB"},{"key":"10.1016\/j.prosdent.2024.03.020_bib2","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1067\/mpr.2001.118021","article-title":"A review of 243 errors possible during the fabrication of a removable partial denture: Part I","volume":"86","author":"Rudd","year":"2001","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib3","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.dental.2011.10.014","article-title":"The future of dental devices is digital","volume":"28","author":"Van Noort","year":"2012","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2024.03.020_bib4","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1046\/j.1365-2842.2002.00898.x","article-title":"Complications and failures in removable partial dentures: A clinical evaluation","volume":"29","author":"Saito","year":"2002","journal-title":"J Oral Rehabil"},{"key":"10.1016\/j.prosdent.2024.03.020_bib5","first-page":"73","article-title":"Additive manufacturing: A novel method for fabricating cobalt-chromium removable partial denture frameworks","volume":"25","author":"Alifui-Segbaya","year":"2017","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib6","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.prosdent.2006.05.029","article-title":"Use of CAD\/CAM technology to fabricate a removable partial denture framework","volume":"96","author":"Williams","year":"2006","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib7","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1243\/095441105X9372","article-title":"The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks","volume":"219","author":"Eggbeer","year":"2005","journal-title":"Proc Inst Mech Eng H: J Eng Med"},{"key":"10.1016\/j.prosdent.2024.03.020_bib8","series-title":"Stewart's Clinical Removable Partial Prosthodontics","author":"Phoenix","year":"2003"},{"key":"10.1016\/j.prosdent.2024.03.020_bib9","first-page":"127","article-title":"Accuracy of fit of cobalt-chromium removable partial denture frameworks on master casts","volume":"1","author":"Fenlon","year":"1993","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib10","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1111\/jopr.13075","article-title":"Virtual evaluation of the accuracy of fit and trueness in maxillary poly (etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD\/CAM techniques","volume":"28","author":"Negm","year":"2019","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2024.03.020_bib11","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1111\/jopr.12997","article-title":"An in vitro investigation of accuracy and fit of conventional and CAD\/CAM removable partial denture frameworks","volume":"28","author":"Soltanzadeh","year":"2019","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2024.03.020_bib12","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.prosdent.2006.02.001","article-title":"clinical investigation of the fit of removable partial dental prosthesis clasp assemblies","volume":"95","author":"Dunham","year":"2006","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib13","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.prosdent.2018.11.010","article-title":"Adaptation of removable partial denture frameworks fabricated by selective laser melting","volume":"122","author":"Chen","year":"2019","journal-title":"J Prosthet Dent"},{"issue":"530","key":"10.1016\/j.prosdent.2024.03.020_bib14","first-page":"e1","article-title":"Physicomechanical properties of cobalt-chromium removable partial denture palatal major connectors fabricated by selective laser melting","volume":"128","author":"Salim","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib15","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.prosdent.2018.12.007","article-title":"The effect of build orientation on the microstructure and properties of selective laser melting Ti-6Al-4V for removable partial denture clasps","volume":"123","author":"Xie","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib16","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.prosdent.2020.06.035","article-title":"Trueness of removable partial denture frameworks additively manufactured with selective laser melting","volume":"127","author":"Peng","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib17","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.jpor.2019.07.009","article-title":"Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering","volume":"64","author":"Tasaka","year":"2020","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2024.03.020_bib18","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.prosdent.2021.04.021","article-title":"Process parameter optimization for removable partial denture frameworks manufactured by selective laser melting","volume":"129","author":"Hwang","year":"2021","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib19","doi-asserted-by":"crossref","first-page":"1625","DOI":"10.1108\/RPJ-11-2021-0324","article-title":"Effects of selective laser melting process parameters on the accuracy of the intaglio surface of maxillary removable partial denture frameworks","volume":"28","author":"Chen","year":"2022","journal-title":"Rapid Prototyp J"},{"key":"10.1016\/j.prosdent.2024.03.020_bib20","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1016\/0022-3913(92)90552-L","article-title":"The tooth-removable partial denture interface","volume":"68","author":"Brudvik","year":"1992","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib21","doi-asserted-by":"crossref","first-page":"348","DOI":"10.11607\/ijp.5270","article-title":"Preliminary clinical application of removable partial denture frameworks fabricated using computer-aided design and rapid prototyping techniques","volume":"30","author":"Ye","year":"2017","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2024.03.020_bib22","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.prosdent.2021.12.021","article-title":"Comparative clinical evaluation of removable partial denture frameworks fabricated traditionally or with selective laser melting: A randomized controlled trial","volume":"131","author":"Chia","year":"2024","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.03.020_bib23","doi-asserted-by":"crossref","first-page":"474","DOI":"10.11607\/ijp.5079","article-title":"Additive manufacturing techniques in prosthodontics: Where do we currently stand? A critical review","volume":"30","author":"Alharbi","year":"2017","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2024.03.020_bib24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41598-017-17839-4","article-title":"Comparison of adaptation between the major connectors fabricated from intraoral digital impressions and extraoral digital impressions","volume":"8","author":"Gan","year":"2018","journal-title":"Sci Rep"},{"key":"10.1016\/j.prosdent.2024.03.020_bib25","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/S0022-3913(97)70162-8","article-title":"The effect of storage time of removable partial denture wax pattern on the accuracy of fit of the cast framework","volume":"77","author":"Diwan","year":"1997","journal-title":"J Prosthet Dent"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391324002129?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391324002129?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T00:57:32Z","timestamp":1763600252000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391324002129"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11]]},"references-count":25,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["S0022391324002129"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2024.03.020","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2025,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Adaptation of cobalt chromium frameworks fabricated by conventional versus selective laser melting techniques: An in vitro and clinical assessment","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2024.03.020","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2025 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}