{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T18:22:37Z","timestamp":1769106157585,"version":"3.49.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["prosdent.org","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2024,12]]},"DOI":"10.1016\/j.prosdent.2024.09.004","type":"journal-article","created":{"date-parts":[[2024,9,20]],"date-time":"2024-09-20T03:40:00Z","timestamp":1726803600000},"page":"1328.e1-1328.e6","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Effect of ceramic thickness on the polymerization quality and film thickness of dual-polymerizing versus heated light-polymerizing adhesive cement"],"prefix":"10.1016","volume":"132","author":[{"given":"Bilal","family":"Secundar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amirhossein","family":"Fathi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kimia","family":"Baghaei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ramin","family":"Atash","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2024.09.004_bib1","first-page":"493","article-title":"Survival of zirconia- and metal-supported fixed dental prostheses: A systematic review","volume":"23","author":"Heintze","year":"2010","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2024.09.004_bib2","doi-asserted-by":"crossref","first-page":"164","DOI":"10.11607\/ijp.3229","article-title":"Prospective evaluation of zirconia posterior fixed partial dentures: 7-Year clinical results","volume":"26","author":"Rinke","year":"2013","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2024.09.004_bib3","doi-asserted-by":"crossref","first-page":"212","DOI":"10.4103\/jips.jips_165_17","article-title":"Comparison between shear forces applied on the onlay-dental tissue interface using different bonding techniques: An in vitro study","volume":"18","author":"Reboul","year":"2018","journal-title":"J Indian Prosthodont Soc"},{"key":"10.1016\/j.prosdent.2024.09.004_bib4","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1007\/s007840100118","article-title":"Curing efficiency of different polymerization methods through ceramic restorations","volume":"5","author":"Jung","year":"2001","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2024.09.004_bib5","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1016\/j.dental.2004.02.003","article-title":"Use of near-IR to monitor the influence of external heating on dental composite photopolymerization","volume":"20","author":"Trujillo","year":"2004","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2024.09.004_bib6","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1177\/154405910508400716","article-title":"Monomer conversion of preheated composite","volume":"84","author":"Daronch","year":"2005","journal-title":"J Dent Res"},{"key":"10.1016\/j.prosdent.2024.09.004_bib7","first-page":"46","article-title":"Thermally assisted flow and polymerization of composite resins","volume":"7","author":"Friedman","year":"2003","journal-title":"Contemp Esthet Restor Pract"},{"key":"10.1016\/j.prosdent.2024.09.004_bib8","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1002\/1527-2648(200110)3:10<763::AID-ADEM763>3.0.CO;2-C","article-title":"Luting cement, the stronghold or the weak link in ceramic restorations?","volume":"3","author":"Davidson","year":"2001","journal-title":"Adv Eng Mater"},{"key":"10.1016\/j.prosdent.2024.09.004_bib9","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.dental.2012.11.005","article-title":"Progress in dimethacrylate-based dental composite technology and curing efficiency","volume":"29","author":"Leprince","year":"2013","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2024.09.004_bib10","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1016\/j.dental.2007.06.014","article-title":"Influence of ceramic thickness on mechanical properties and polymer structure of dual-cured resin luting agents","volume":"24","author":"Meng","year":"2008","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2024.09.004_bib11","doi-asserted-by":"crossref","first-page":"e169","DOI":"10.1016\/j.dental.2013.04.021","article-title":"Polymerization development of \u201clow-shrink\u201d resin composites: Reaction kinetics, polymerization stress and quality of network","volume":"29","author":"Yamasaki","year":"2013","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2024.09.004_bib12","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1111\/jerd.12390","article-title":"Influence of monolithic lithium disilicate and zirconia thickness on polymerization efficiency of dual-cure resin cements","volume":"30","author":"Turp","year":"2018","journal-title":"J Esthet Restor Dent"},{"key":"10.1016\/j.prosdent.2024.09.004_bib13","article-title":"Hardness and postgel shrinkage of preheated composites","volume":"42","author":"Tantbirojn","year":"2011","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2024.09.004_bib14","first-page":"40","article-title":"Adhesive resin cements for bonding esthetic restorations: a review","volume":"34","author":"Duarte","year":"2011","journal-title":"Quintessence Dent Technol"},{"key":"10.1016\/j.prosdent.2024.09.004_bib15","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1111\/j.1532-849X.1994.tb00146.x","article-title":"Effect of restoration composition, shade, and thickness on the cure of a photoactivated resin cement","volume":"3","author":"Myers","year":"1994","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2024.09.004_bib16","first-page":"77","article-title":"Reconstitutions coronaires en c\u00e9ramique: utilisation raisonn\u00e9e des composites de collage [Coronal ceramic reconstructions: rational use of bonding composites]","volume":"2","author":"Gerdlle","year":"2003","journal-title":"Clinic"},{"key":"10.1016\/j.prosdent.2024.09.004_bib17","article-title":"Effect of gap dimension on composite resin cement wear","volume":"25","author":"Kawai","year":"1994","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2024.09.004_bib18","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1111\/j.1708-8240.2006.00046.x","article-title":"Clinically relevant issues related to preheating composites","volume":"18","author":"Daronch","year":"2006","journal-title":"J Esthet Restor Dent"},{"key":"10.1016\/j.prosdent.2024.09.004_bib19","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1016\/j.dental.2005.02.004","article-title":"Polymerization shrinkage and contraction stress of dental resin composites","volume":"21","author":"Kleverlaan","year":"2005","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2024.09.004_bib20","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1016\/j.prosdent.2016.08.029","article-title":"Volumetric shrinkage and film thickness of cementation materials for veneers: An in vitro 3D microcomputed tomography analysis","volume":"117","author":"Sampaio","year":"2017","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.09.004_bib21","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/S0022-3913(10)60111-4","article-title":"In vitro fatigue resistance of CAD\/CAM composite resin and ceramic posterior occlusal veneers","volume":"104","author":"Magne","year":"2010","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.09.004_bib22","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1111\/j.1365-2842.1997.tb00375.x","article-title":"Film thickness of various dentine bonding agents","volume":"24","author":"Peter","year":"1997","journal-title":"J Oral Rehabil"},{"key":"10.1016\/j.prosdent.2024.09.004_bib23","doi-asserted-by":"crossref","first-page":"72","DOI":"10.2341\/07-41","article-title":"Effect of preheating resin composite on restoration microleakage","volume":"33","author":"Wagner","year":"2008","journal-title":"Oper Dent"},{"key":"10.1016\/j.prosdent.2024.09.004_bib24","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1002\/(SICI)1097-4636(1999)48:5<675::AID-JBM11>3.0.CO;2-P","article-title":"The micro-Raman spectroscopy, a useful tool to determine the degree of conversion of light-activated composite resins","volume":"48","author":"Pianelli","year":"1999","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.prosdent.2024.09.004_bib25","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1111\/j.1708-8240.2000.tb00243.x","article-title":"Polymerization depths of contemporary light-curing units using microhardness","volume":"12","author":"Rueggeberg","year":"2000","journal-title":"J Esthet Dent"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391324006048?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391324006048?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,12,8]],"date-time":"2024-12-08T13:57:06Z","timestamp":1733666226000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391324006048"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12]]},"references-count":25,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["S0022391324006048"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2024.09.004","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of ceramic thickness on the polymerization quality and film thickness of dual-polymerizing versus heated light-polymerizing adhesive cement","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2024.09.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2024 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}