{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T08:43:34Z","timestamp":1788857014191,"version":"build-2803163510"},"reference-count":34,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100003392","name":"Fujian Provincial Natural Science Foundation","doi-asserted-by":"publisher","award":["2023Y0054"],"award-info":[{"award-number":["2023Y0054"]}],"id":[{"id":"10.13039\/501100003392","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100017686","name":"Fujian Provincial Health Technology Project","doi-asserted-by":"publisher","award":["2021GGB018"],"award-info":[{"award-number":["2021GGB018"]}],"id":[{"id":"10.13039\/501100017686","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["prosdent.org","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2025,1]]},"DOI":"10.1016\/j.prosdent.2024.09.017","type":"journal-article","created":{"date-parts":[[2024,10,18]],"date-time":"2024-10-18T17:52:59Z","timestamp":1729273979000},"page":"230.e1-230.e8","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Elastic and fatigue properties of additively manufactured and milled Ti-6Al-4V removable partial denture clasps"],"prefix":"10.1016","volume":"133","author":[{"given":"Minrui","family":"Xu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhenxiang","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6285-906X","authenticated-orcid":false,"given":"Hui","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2024.09.017_bib1","doi-asserted-by":"crossref","DOI":"10.1016\/j.matdes.2018.107552","article-title":"Additive manufacturing of Ti6Al4V alloy: A review","volume":"164","author":"Liu","year":"2019","journal-title":"Mater Des"},{"key":"10.1016\/j.prosdent.2024.09.017_bib2","doi-asserted-by":"crossref","first-page":"517","DOI":"10.4012\/dmj.2017-137","article-title":"Titanium removable denture based on a one metal rehabilitation concept","volume":"36","author":"Ohkubo","year":"2017","journal-title":"Dent Mater J"},{"key":"10.1016\/j.prosdent.2024.09.017_bib3","doi-asserted-by":"crossref","first-page":"619","DOI":"10.4012\/dmj.2023-113","article-title":"Surveillance study on the application of titanium and its alloys to removable dental prostheses","volume":"4","author":"Koizumi","year":"2023","journal-title":"Dent Mater J"},{"key":"10.1016\/j.prosdent.2024.09.017_bib4","article-title":"Mechanical properties and accuracy of removable partial denture frameworks fabricated by digital and conventional techniques: A systematic review","author":"Souza Curinga","year":"2023","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.09.017_bib5","article-title":"Main applications and recent research progresses of additive manufacturing in dentistry","volume":"2022","author":"Huang","year":"2022","journal-title":"Biomed Res Int"},{"key":"10.1016\/j.prosdent.2024.09.017_bib6","doi-asserted-by":"crossref","first-page":"4641","DOI":"10.1016\/j.jmrt.2022.04.055","article-title":"A critical review on additive manufacturing of Ti-6Al-4V alloy: Microstructure and mechanical properties","volume":"18","author":"Nguye","year":"2022","journal-title":"J Mater Res Technol"},{"key":"10.1016\/j.prosdent.2024.09.017_bib7","doi-asserted-by":"crossref","first-page":"1911","DOI":"10.1557\/jmr.2014.157","article-title":"On the fatigue properties of metals manufactured by selective laser melting \u2014 The role of ductility","volume":"29","author":"Leuders","year":"2014","journal-title":"J Mater Res"},{"key":"10.1016\/j.prosdent.2024.09.017_bib8","doi-asserted-by":"crossref","first-page":"609","DOI":"10.3390\/ma13030609","article-title":"Microstructures and mechanical properties of laser-sintered commercially pure Ti and Ti-6Al-4V alloy for dental applications","volume":"13","author":"Okazaki","year":"2020","journal-title":"Materials (Basel)"},{"key":"10.1016\/j.prosdent.2024.09.017_bib9","doi-asserted-by":"crossref","first-page":"1523","DOI":"10.1002\/jbm.b.35014","article-title":"Mechanical properties, corrosion resistance, and anti-adherence characterization of pure titanium fabricated by casting, milling, and selective laser melting","volume":"110","author":"Wang","year":"2022","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"10.1016\/j.prosdent.2024.09.017_bib10","doi-asserted-by":"crossref","DOI":"10.1016\/j.matchar.2020.110780","article-title":"Deformation behavior of Ti-6Al-4V microstructures under uniaxial loading: Equiaxed Vs. transformed-\u03b2 microstructures","volume":"171","author":"Jha","year":"2021","journal-title":"Mater Charact"},{"key":"10.1016\/j.prosdent.2024.09.017_bib11","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.3390\/met9101041","article-title":"Evaluation of low cycle fatigue performance of selective laser melted titanium alloy Ti\u20136Al\u20134V","volume":"9","author":"Zhang","year":"2019","journal-title":"Metals"},{"key":"10.1016\/j.prosdent.2024.09.017_bib12","doi-asserted-by":"crossref","DOI":"10.1016\/j.matlet.2020.128800","article-title":"A survey of fatigue properties from wrought and additively manufactured Ti-6Al-4V","volume":"283","author":"Rao","year":"2021","journal-title":"Mater Lett"},{"key":"10.1016\/j.prosdent.2024.09.017_bib13","doi-asserted-by":"crossref","first-page":"75","DOI":"10.3390\/met8010075","article-title":"A review of the as-built SLM Ti-6Al-4V mechanical properties towards achieving fatigue resistant designs","volume":"8","author":"Agius","year":"2018","journal-title":"Metals"},{"key":"10.1016\/j.prosdent.2024.09.017_bib14","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1016\/j.jpor.2020.01.001","article-title":"Fitness accuracy and retentive forces of additive manufactured titanium clasp","volume":"64","author":"Takahashi","year":"2020","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2024.09.017_bib15","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.prosdent.2018.12.007","article-title":"The effect of build orientation on the microstructure and properties of selective laser melting Ti-6Al-4V for removable partial denture clasps","volume":"123","author":"Xie","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.09.017_bib16","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.jpor.2018.08.002","article-title":"Titanium clasp fabricated by selective laser melting, CNC milling, and conventional casting: A comparative in vitro study","volume":"63","author":"Tan","year":"2019","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2024.09.017_bib17","doi-asserted-by":"crossref","first-page":"109","DOI":"10.4047\/jap.2012.4.2.109","article-title":"Complication rates and patient satisfaction with removable dentures","volume":"4","author":"Bilhan","year":"2012","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2024.09.017_bib18","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/S0022-3913(10)60173-4","article-title":"Cyclic fatigue properties of cobalt-chromium alloy clasps for partial removable dental prostheses","volume":"104","author":"Cheng","year":"2010","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.09.017_bib19","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1088\/0031-9155\/3\/3\/303","article-title":"An analysis of clasp design in partial dentures","volume":"3","author":"Warr","year":"1959","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.prosdent.2024.09.017_bib20","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.identj.2021.01.005","article-title":"Guidelines for the choice of circumferential wrought wire and cast clasp arms for removable partial dentures","volume":"72","author":"Owen","year":"2022","journal-title":"Int Dent J"},{"key":"10.1016\/j.prosdent.2024.09.017_bib21","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.prosdent.2017.01.008","article-title":"Removable partial dentures: The clinical need for innovation","volume":"118","author":"Campbell","year":"2017","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.09.017_bib22","doi-asserted-by":"crossref","first-page":"1474","DOI":"10.1016\/j.dental.2018.06.011","article-title":"An analytical model to design circumferential clasps for laser-sintered removable partial dentures","volume":"34","author":"Alsheghri","year":"2018","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2024.09.017_bib23","doi-asserted-by":"crossref","first-page":"414","DOI":"10.4012\/dmj.2021-285","article-title":"Fitness accuracy and retentive forces of milled titanium clasp","volume":"41","author":"Maruo","year":"2022","journal-title":"Dent Mater J"},{"key":"10.1016\/j.prosdent.2024.09.017_bib24","first-page":"22674","article-title":"Dentistry\u2014metallic materials for fixed and removable restorations and appliances.","author":"Gene\u2019va","year":"2016","journal-title":"EN ISO"},{"key":"10.1016\/j.prosdent.2024.09.017_bib25","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.jmbbm.2016.02.032","article-title":"Fatigue strength of Co-Cr-Mo alloy clasps prepared by selective laser melting","volume":"59","author":"Kajima","year":"2016","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2024.09.017_bib26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jmbbm.2017.11.009","article-title":"Effect of adding support structures for overhanging part on fatigue strength in selective laser melting","volume":"78","author":"Kajima","year":"2018","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2024.09.017_bib27","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.jmbbm.2019.06.010","article-title":"Fatigue properties of removable partial denture clasps fabricated by selective laser melting followed by heat treatment","volume":"98","author":"Kittikundecha","year":"2019","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2024.09.017_bib28","first-page":"117","article-title":"Mechanical properties and microstructure of removable partial denture clasps manufactured using selective laser melting","volume":"8","author":"Yager","year":"2015","journal-title":"Addit Manuf"},{"key":"10.1016\/j.prosdent.2024.09.017_bib29","doi-asserted-by":"crossref","first-page":"626","DOI":"10.2186\/jpr.JPR_D_22_00207","article-title":"Comparison of the fatigue life of pure titanium and titanium alloy clasps manufactured by laser powder bed fusion and its prediction before manufacturing","volume":"67","author":"Odaka","year":"2023","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2024.09.017_bib30","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1038\/sj.bdj.4800887a","article-title":"Clasp design","volume":"190","author":"Davenport","year":"2001","journal-title":"Br Dent J"},{"key":"10.1016\/j.prosdent.2024.09.017_bib31","doi-asserted-by":"crossref","DOI":"10.1016\/j.ijfatigue.2019.105358","article-title":"Fatigue of additive manufactured Ti-6Al-4V, Part I: The effects of powder feedstock, manufacturing, and post process conditions on the resulting microstructure and defects","volume":"132","author":"Pegues","year":"2020","journal-title":"Int J Fatigue"},{"key":"10.1016\/j.prosdent.2024.09.017_bib32","doi-asserted-by":"crossref","DOI":"10.1016\/j.ijfatigue.2019.105363","article-title":"Fatigue of additive manufactured Ti-6Al-4V, Part II: The relationship between microstructure, material cyclic properties, and component performance","volume":"132","author":"Molaei","year":"2020","journal-title":"Int J Fatigue"},{"key":"10.1016\/j.prosdent.2024.09.017_bib33","doi-asserted-by":"crossref","first-page":"459","DOI":"10.2186\/jpr.JPR_D_21_00017","article-title":"Retentive force and fitness accuracy of cobalt-chrome alloy clasps for removable partial denture fabricated with SLM technique","volume":"66","author":"Zhang","year":"2022","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2024.09.017_bib34","doi-asserted-by":"crossref","first-page":"117","DOI":"10.3390\/ma13010117","article-title":"The effects of ffeature sizes in selectively laser melted Ti-6Al-4V parts on the validity of optimised process parameters","volume":"13","author":"Phutela","year":"2019","journal-title":"Materials (Basel)"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391324006413?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391324006413?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,3,4]],"date-time":"2025-03-04T20:54:19Z","timestamp":1741121659000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391324006413"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":34,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,1]]}},"alternative-id":["S0022391324006413"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2024.09.017","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Elastic and fatigue properties of additively manufactured and milled Ti-6Al-4V removable partial denture clasps","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2024.09.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2025 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}